[Probes]									
Target ID	Species	Build ID	Chromosome	Start Position	End Position	Strand	ULSO Sequence	DLSO Sequence	Probe Strand
AKT1ex2.chr14.105246425.105246553_tile_1	Human	hg19	chr14	105246425	105246553	+	CGAGAGGCCAAGGGGATACTTAC	GTGGTGAGAGCCACGCACACTCTA	+
ALKex23.chr2.29443572.29443701_tile_2	Human	hg19	chr2	29443572	29443701	-	GTAGCTGCTGAAAATGTAACTTTGTATC	GTTCATCCTGCTGGAGCTCATGG	-
APCex15_1.chr5.112173836.112173974_tile_1	Human	hg19	chr5	112173836	112173974	+	GATAATAGGTCAGACAATTTTAATACTGGC	GTCTAGGCAACTACCATCCAGCAACA	+
APCex15_1.chr5.112173836.112173974_tile_2	Human	hg19	chr5	112173836	112173974	-	ACCCAGAACTTCTGTCTTCCTGAGA	AATTCCGCGTTCTCTCTCCAAAC	-
APCex15_2.chr5.112174625.112174757_tile_1	Human	hg19	chr5	112174625	112174757	+	GGAATCAAAGTACAACTTATCCTGTTTAT	AATTAATCAAAATGTAAGCCAGTCTTTGTG	+
APCex15_2.chr5.112174625.112174757_tile_2	Human	hg19	chr5	112174625	112174757	-	CATGACGTTTCTCTTCATTATATTTTATGC	CATGATTAGAACCCACTCGATTTGTTTCT	-
APCex15_3.chr5.112174992.112176072_tile_2	Human	hg19	chr5	112174992	112176072	-	ACATCTTGAAAAACATATTGGAGTATCTT	TGCCTCTTGGCATTAGATGAAGGTGT	-
APCex15_3.chr5.112174992.112176072_tile_3	Human	hg19	chr5	112174992	112176072	+	GCAAAGTTTCTTCTATTAACCAAGAAACA	GCAGATTCTGCTAATACCCTGCAAATAG	+
APCex15_3.chr5.112174992.112176072_tile_4	Human	hg19	chr5	112174992	112176072	-	ATTTGGTTCTAGGGTGCTGTGACACTGCT	CCTATTTCATCTTCAGCTGATGACAAAG	-
APCex15_3.chr5.112174992.112176072_tile_5	Human	hg19	chr5	112174992	112176072	+	AACTAGGTCAGCTGAAGATCCTGTGA	TCCCTCCAAAAGTGGTGCTCAGA	+
APCex15_3.chr5.112174992.112176072_tile_7	Human	hg19	chr5	112174992	112176072	+	TTTAGCAGATGTACTTCTGTCAGTTCAC	TGCCACCAAGCAGAAGTAAAACACCT	+
APCex15_3.chr5.112174992.112176072_tile_8	Human	hg19	chr5	112174992	112176072	-	GCAGCATTTACTGCAGCTTGCTT	AGGGCTATCTGGAAGATCACTGGG	-
APCex15_3.chr5.112174992.112176072_tile_9	Human	hg19	chr5	112174992	112176072	+	ATAAAGCACCTACTGCTGAAAAGAGAG	TTCATCCAGCCTGAGTGCTCTGA	+
APCex15_3.chr5.112174992.112176072_tile_10	Human	hg19	chr5	112174992	112176072	-	TTGATTCTTTAGGCTGCTCTGATTCTG	CATCTGGAGTACTTTCCGTGGCAAAA	-
APCex15_3.chr5.112174992.112176072_tile_11	Human	hg19	chr5	112174992	112176072	+	TCCAGTTCAGGAAAATGACAATGGGA	ACTAGAAGAATGTATTATTTCTGCCATGCC	+
APCex15_3.chr5.112174992.112176072_tile_12	Human	hg19	chr5	112174992	112176072	-	CCTGTTTTGTGATGGTAGAAGTTTGTACAC	CATCATCATCTGAATCATCTAATAGGTCCT	-
BRAFex11.chr7.140481376.140481493_tile_1	Human	hg19	chr7	140481376	140481493	+	TGAAACTAATCAAAATAGTTTATTGATGCG	TTCCCTTGTAGACTGTTCCAAATGATCC	+
BRAFex11.chr7.140481376.140481493_tile_2	Human	hg19	chr7	140481376	140481493	-	AAGGTTTTCTTTTTCTGTTTGGCTTGA	GTGGCATGGTAAGTATGTAATGTGGTG	-
BRAFex15.chr7.140453075.140453193_tile_1	Human	hg19	chr7	140453075	140453193	+	TAATCAGTGGAAAAATAGCCTCAATTCT	GAGGTGTAGTAAGTAAAGGAAAACAGT	+
CDH1ex8.chr16.68846038.68846166_tile_1	Human	hg19	chr16	68846038	68846166	+	AGAAGACAGGCAGGCTGGCATGAA	GTGGTTCAAGCTGCTGACCTTCAA	+
CDH1ex8.chr16.68846038.68846166_tile_2	Human	hg19	chr16	68846038	68846166	-	CCTTTCTTTGGAAACCCTCTAAGGAGTT	AGGGTATACGTAGGGAAACTCTGCA	-
CDH1ex9.chr16.68847216.68847398_tile_2	Human	hg19	chr16	68847216	68847398	-	GTGACGACAAATTGTCCACCATCATCA	CAGAGCAAAGAGATGTGTCATTTACAAAGT	-
CDH1ex9.chr16.68847216.68847398_tile_3	Human	hg19	chr16	68847216	68847398	+	CGTGGGAGGCTGTATACACCATATTGA	CTGGTATCTTCTTAGAAGTAGATTCGC	+
CDH1ex12.chr16.68855904.68856128_tile_2	Human	hg19	chr16	68855904	68856128	-	TGATGTTTATGACCTGAGGCTTTGGAT	GAAAATACACAGAAAATGTGGCAGCTT	-
CDH1ex12.chr16.68855904.68856128_tile_3	Human	hg19	chr16	68855904	68856128	+	CCTCGAACTATATTCTTCTGTGAGAGG	GTGGGTACCTGAGTTTTATTTTGGCAAC	+
CTNNB1ex2.chr3.41266017.41266151_tile_1	Human	hg19	chr3	41266017	41266151	+	TGGCTGTCTTTCAGATTTGACTTTATTTC	TGGACATGGCCATGGAACCAGACAGAAAA	+
CTNNB1ex2.chr3.41266017.41266151_tile_2	Human	hg19	chr3	41266017	41266151	-	TTGGGAGGTATCCACATCCTCTTCC	CTCCATCAAATCAGCTATAAATACGAAAC	-
EGFRex18.chr7.55241613.55241736_tile_1	Human	hg19	chr7	55241613	55241736	+	CTGGGCCATGTCTGGCACTGCTTT	AAGGAAACTGAATTCAAAAAGATCAAAGTG	+
EGFRex18.chr7.55241613.55241736_tile_2	Human	hg19	chr7	55241613	55241736	-	TGGAAATATACAGCTTGCAAGGACTCT	AAGATCCTCAAGAGAGCTTGGTTGGGA	-
EGFRex19.chr7.55242414.55242513_tile_1	Human	hg19	chr7	55242414	55242513	+	GTTAACGTCTTCCTTCTCTCTCTGTCA	TGAACCTCAGGCCCACCTTTTCTCAT	+
EGFRex20.chr7.55248985.55249171_tile_1	Human	hg19	chr7	55248985	55249171	-	ATAGTCCAGGAGGCAGCCGAAGGGCATGAG	AAGGAGGGGCACATGGACCCCTTCCAG	-
EGFRex20.chr7.55248985.55249171_tile_2	Human	hg19	chr7	55248985	55249171	+	TCCACCGTGCAGCTCATCACGCA	AGCCAGGATCCTCACATGCGGTCT	+
EGFRex21.chr7.55259411.55259567_tile_1	Human	hg19	chr7	55259411	55259567	+	TCAGAGCCTGGCATGAACATGAC	AGCATGTCAAGATCACAGATTTTGGGC	+
EGFRex21.chr7.55259411.55259567_tile_2	Human	hg19	chr7	55259411	55259567	-	GTGTTAAACAATACAGCTAGTGGGAAG	CGGTGTTTTCACCAGTACGTTCC	-
ERBB2ex20.chr17.37880979.37881164_tile_2	Human	hg19	chr17	37880979	37881164	-	TCCGCGGTTTTCCCGGACATGGT	GACAAGGGTACGCTGAGAGGGT	-
ERBB2ex20.chr17.37880979.37881164_tile_3	Human	hg19	chr17	37880979	37881164	+	CAGCTTATGCCCTATGGCTGCCTCTTA	CAAGGGGCTAGGATGGGGACTCTT	+
FBXW7ex7.chr4.153250824.153250937_tile_1	Human	hg19	chr4	153250824	153250937	+	GCTCTGATATTTGCTATCCAAATAACTAAG	CTGCTGACCAAACTTTTAAAGTGTTGTC	+
FBXW7ex7.chr4.153250824.153250937_tile_2	Human	hg19	chr4	153250824	153250937	-	TTAACATATTTCTAATCTGCACATCTTTCT	CACAGGCAAAGTAAGTTTACTCTTCCT	-
FBXW7ex8.chr4.153249360.153249541_tile_1	Human	hg19	chr4	153249360	153249541	+	AATTAAATCTAATTTAAGAGCACACTGTCA	GCACAGTGGAAGTATGCCCATATAAGG	+
FBXW7ex8.chr4.153249360.153249541_tile_2	Human	hg19	chr4	153249360	153249541	-	GGTGGAGTATGGTCATCACAAATGAGAG	GTAAGGGAAAATCTTGTCATGGTTGGG	-
FBXW7ex8.chr4.153249360.153249541_tile_3	Human	hg19	chr4	153249360	153249541	+	GATCTGTAGATCCACTAATGATGATGTTG	AGCTCATTAAAATTTGGAGTAAAGTTACT	+
FBXW7ex9.chr4.153247158.153247383_tile_1	Human	hg19	chr4	153247158	153247383	+	TTTTGGACTGTACTGGATCAGCAATTTG	GTGTGTAGACAGGTTTCAGTCTCTGGA	+
FBXW7ex9.chr4.153247158.153247383_tile_2	Human	hg19	chr4	153247158	153247383	-	CAGGCCAGTGTTTACATGTTTTGATGG	GGCATACTAATAGAGTCTATTCATTACAGG	-
FBXW7ex9.chr4.153247158.153247383_tile_3	Human	hg19	chr4	153247158	153247383	+	CACAGCGGACTGCTGCAACATGA	ATGAGAAAACATGGTAGATTTAGTCAAGG	+
FBXW7ex10.chr4.153245336.153245546_tile_2	Human	hg19	chr4	153245336	153245546	-	TAACAGGGCACCAGTCGTTAACAAGTGGA	TTCGTTTTGTTCATTAAAAATGAGATCATT	-
FBXW7ex10.chr4.153245336.153245546_tile_3	Human	hg19	chr4	153245336	153245546	+	AGACAAGAATATTGTCTTTGAGTTCCA	GAATAGAAGTATGGATACTCTTCCTATCAA	+
FBXW7ex11.chr4.153244033.153244301_tile_1	Human	hg19	chr4	153244033	153244301	+	ACATCCTGCACCACTGAGAACAA	CAAAGTCCAGCACCAGCAGCTTGGTTT	+
FBXW7ex11.chr4.153244033.153244301_tile_2	Human	hg19	chr4	153244033	153244301	-	CTATGGGACTTGAAAACGGGTGAATTTA	GTGGACATGAAGTGAAGAGCAGAAAA	-
FBXW7ex11.chr4.153244033.153244301_tile_3	Human	hg19	chr4	153244033	153244301	+	ACTCTCCAATGTGACTAGGTTTCGA	AGACAAAAACCAAAAGAATTTAATTACTGG	+
FGFR2ex6.chr10.123279493.123279683_tile_1	Human	hg19	chr10	123279493	123279683	+	TCTCTCAACTCCAACAGGAAATCAAAG	TGGATGTGGGGCTGGGCATCACTGTAAA	+
FGFR2ex6.chr10.123279493.123279683_tile_2	Human	hg19	chr10	123279493	123279683	-	ATCCCCACTCCTCCTTTCTTCCC	TGGATCAAGCACGTGGAAAAGAACG	-
FOXL2ex1.chr3.138665113.138665213_tile_1	Human	hg19	chr3	138665113	138665213	+	CTGGAAGTGCGCGGGCGGCGGCCGGAA	CCTTGATGAAGCACTCGTTGAGGCTGA	+
GNAQex4.chr9.80412436.80412564_tile_1	Human	hg19	chr9	80412436	80412564	+	ATAATTGGTATAAAGCCTATCTTGTTTTGA	AGTCAAAGGGGTATTCGATGATCCCT	+
GNAQex4.chr9.80412436.80412564_tile_2	Human	hg19	chr9	80412436	80412564	-	GTGTGATGGTGTCACTGACATTCTCA	ACAAAGTGTCATTTTCAGGTAGTAACT	-
GNAQex5.chr9.80409379.80409508_tile_2	Human	hg19	chr9	80409379	80409508	-	ATGTAGGGGGCCAAAGGTCAGAG	AGGCAATGGATTATCATTTTATTATCTGAT	-
GNAQex5.chr9.80409379.80409508_tile_3	Human	hg19	chr9	80409379	80409508	+	ATTTTCAAAGCAGTGTATCCATTTTCTTC	CTCTTGAATGACGATGATCATCCAAGTC	+
GNAQex6.chr9.80343430.80343583_tile_2	Human	hg19	chr9	80343430	80343583	-	AGAACCGAATGGAGGAAAGCAAGGC	TCAGCACTCATACCACAGCTCAGTAG	-
GNAQex6.chr9.80343430.80343583_tile_3	Human	hg19	chr9	80343430	80343583	+	CAGGGGTATGTGATAATTGTTCTAAAGAG	GTTTTTGTAGCCCTGTGTTGGATTTGTC	+
GNASex6.chr20.57480438.57480535_tile_1	Human	hg19	chr20	57480438	57480535	+	TTCAAGCTCTTGCCTTTCTCTAAACTT	ACCCAACCCATCAGCACATAAAACAG	+
GNASex8.chr20.57484405.57484478_tile_1	Human	hg19	chr20	57484405	57484478	+	GTGAGATCCATTGACCTCAATTTTGTTTC	CCCAGTCCCTCTGGAATAACCAGCTGT	+
KITex9.chr4.55592023.55592216_tile_1	Human	hg19	chr4	55592023	55592216	+	TTGTAAAAGGACATTTTCTGTTGATTATGA	GTACTGCCAGTGGATGTGCAGACACTAAA	+
KITex9.chr4.55592023.55592216_tile_2	Human	hg19	chr4	55592023	55592216	-	TTGCCCACATCGTTGTAAGCCTTAC	CATCTAAAGGGAAGAAAACAAAAGCCCT	-
KITex9.chr4.55592023.55592216_tile_3	Human	hg19	chr4	55592023	55592216	+	GCATTCAAGCACAATGGCACGGTTGAA	ACCATATCAGTCATGATTTTAAGTTCATTC	+
KITex11.chr4.55593581.55593708_tile_1	Human	hg19	chr4	55593581	55593708	+	TGTGATGATTCTGACCTACAAATATTTAC	GTGGAAGGTTGTTGAGGAGATAAATGG	+
KITex11.chr4.55593581.55593708_tile_2	Human	hg19	chr4	55593581	55593708	-	GTTATGTGTACCCAAAAAGGTGACATG	GTACTTCATACATGGGTTTCTGTGGGG	-
KITex13.chr4.55594176.55594287_tile_1	Human	hg19	chr4	55594176	55594287	+	TTTTGCTAAAATGCATGTTTCCAATTT	TCCAAGCTGCCTTTTATTGTCTGTCAG	+
KITex17.chr4.55599235.55599358_tile_1	Human	hg19	chr4	55599235	55599358	-	GGTACTCACGTTTCCTTTAACCACATAATT	GGAGGAGAAAAGAAAACCATTTAAATTCAT	-
KITex17.chr4.55599235.55599358_tile_2	Human	hg19	chr4	55599235	55599358	+	TCTAGCCAGAGACATCAAGAATGATTC	TCACACATTTTAGCAGTCAAATTAAGTAT	+
KITex18.chr4.55602664.55602775_tile_1	Human	hg19	chr4	55602664	55602775	+	CATTATTGACTCTGTTGTGCTTCTATTAC	TCCTTGCCAAAGACAACTTCATTAGAC	+
KRASex1.chr12.25398208.25398329_tile_1	Human	hg19	chr12	25398208	25398329	+	TCTTGTAATAAGTACTCATGAAAATGGTC	GTATCGTCAAGGCACTCTTGCCTA	+
KRASex1.chr12.25398208.25398329_tile_2	Human	hg19	chr12	25398208	25398329	-	GGTACTGGTGGAGTATTTGATAGTGTATTA	GCTAATTCAGAATCATTTTGTGGACGAAT	-
KRASex2.chr12.25380168.25380346_tile_1	Human	hg19	chr12	25380168	25380346	+	TAAATATTATATGCATGGCATTAGCAAAGA	CAGTCCTCATGTACTGGTCCCTCATT	+
KRASex2.chr12.25380168.25380346_tile_2	Human	hg19	chr12	25380168	25380346	-	CACTGTAATAATCCAGACTGTGTTTCTCC	GGAGGGCTTTCTTTGTGTATTTGCC	-
KRASex3.chr12.25378548.25378707_tile_1	Human	hg19	chr12	25378548	25378707	+	CCTAGTATAGCATAATTGAGAGAAAAACTG	AACTTCTTGCTAAGTCCTGAGCCTGT	+
KRASex3.chr12.25378548.25378707_tile_2	Human	hg19	chr12	25378548	25378707	-	ATTTGTGTTACTAATGACTGTGCTATAAC	TGGAATTCCTTTTATTGAAACATCAGC	-
KRASex4.chr12.25362729.25362845_tile_1	Human	hg19	chr12	25362729	25362845	+	AAGCTAACAGTCTGCATGGAGCAGGAA	TTTCTTCTTTTTACCATCTTTGCTCATC	+
KRASex4.chr12.25362729.25362845_tile_2	Human	hg19	chr12	25362729	25362845	-	GAAATTTGTTACCTGTACACATGAAGC	AGAAGTCAAAGACAAAGTGTGTAATTATG	-
MAP2K1ex2.chr15.66727445.66727495_tile_1	Human	hg19	chr15	66727445	66727495	+	TGATGAGCAGCAGCGAAAGCGCCTTGA	TCATGGCCAGAAAGGTGAGTTTGCCTT	+
METex1.chr7.116339642.116340262_tile_1	Human	hg19	chr7	116339642	116340262	+	ATGATGATCAACTCATTAGCTGTGGCAG	ACTGTGTGGTGAGCGCCCTGGGAGCCAAA	+
METex1.chr7.116339642.116340262_tile_2	Human	hg19	chr7	116339642	116340262	-	GCAATGGATGATCTGGGAAATAAGAAGAAT	TGTGGGGAGAATATGCAGTGAACCTC	-
METex1.chr7.116339642.116340262_tile_3	Human	hg19	chr7	116339642	116340262	+	CTTTCATCTGTAAAGGACCGGTTCATC	CCAGTCCTACATTGATGTTTTACCTGAG	+
METex1.chr7.116339642.116340262_tile_4	Human	hg19	chr7	116339642	116340262	-	GTGTGAAAAGTCTGAGCATCTAGAGTT	CGTCAAAAACATAAAACCATCTTTCGTTTC	-
METex1.chr7.116339642.116340262_tile_5	Human	hg19	chr7	116339642	116340262	+	AATTTTATTTACTTCTTGACGGTCCAAAGG	AAAAAGAGATCCACAAAGAAGGAAGTG	+
METex1.chr7.116339642.116340262_tile_6	Human	hg19	chr7	116339642	116340262	-	TTCGGCAGAATCTGGCTTGCTTTGT	CTCTTTTCTGTGAGAATACACTCCAGA	-
METex1.chr7.116339642.116340262_tile_7	Human	hg19	chr7	116339642	116340262	+	GATGACATTCTTTTCGGGGTGTTCG	GCATTTTTACGGACCCAATCATGAGC	+
METex4.chr7.116380906.116381079_tile_1	Human	hg19	chr7	116380906	116381079	+	ACACATAGTTGCTAAGTCTAGAAAATTCC	ATGGCTTGGGCTGCAGACATTT	+
METex4.chr7.116380906.116381079_tile_2	Human	hg19	chr7	116380906	116381079	-	AGAGATTCCTACCTTGTAGATTGCAGG	CAATGGGATCTTCGTGATCTGTGAAGA	-
METex4.chr7.116380906.116381079_tile_3	Human	hg19	chr7	116380906	116381079	+	GGACATGGACTCAACAGATCTGTCT	AAAATCAATTTACTCATTTAGCTGTGAGTC	+
METex13.chr7.116411903.116412043_tile_2	Human	hg19	chr7	116411903	116412043	-	AAGTAGCTCGGTAGTCTACAGATTCAT	CAGAGAGAAAGAAAGAGCTTGTTAAAGA	-
METex13.chr7.116411903.116412043_tile_3	Human	hg19	chr7	116411903	116412043	+	GTAAGCCCAACTACAGAAATGGTTTCA	CCTAAAGGAAGTATTTACCTCTGCCAAG	+
METex15.chr7.116417443.116417523_tile_1	Human	hg19	chr7	116417443	116417523	+	GTGCTAACCAAGTTCTTTCTTTTGCAC	TGTGGTTTGCAACCTAATAAATAGCTT	+
METex16.chr7.116418830.116419011_tile_2	Human	hg19	chr7	116418830	116419011	-	CGGAGACCCTTCACTTCGCAGG	GGAGACATTAACTTCATTATGGAACAGTGA	-
METex16.chr7.116418830.116419011_tile_3	Human	hg19	chr7	116418830	116419011	+	TGTCCTCTCGCTCCTGGGAATCT	AAATAGGCCTGCTCTGAGTCTTT	+
METex17.chr7.116422042.116422151_tile_1	Human	hg19	chr7	116422042	116422151	+	TGAGCCATTAAGACCAAACTAATTTTTGAG	TGGTCTTCAAGTAGCCAAAGGCATGA	+
METex17.chr7.116422042.116422151_tile_2	Human	hg19	chr7	116422042	116422151	-	GCATTGAACAGTGGGAAACAGATTCC	AGCCAATAAGATCTTTTACAGTTGGAT	-
METex18.chr7.116423358.116423523_tile_1	Human	hg19	chr7	116423358	116423523	+	AGATGAAATACTTCCTTCAGAAGTTATGG	GATTTTGGTCTTGCCAGAGACATGTATG	+
METex18.chr7.116423358.116423523_tile_2	Human	hg19	chr7	116423358	116423523	-	GAGGAGAAACTCAGAGATAACCAATACAT	GCAACCTTGACTGTGAATTTTTCATCC	-
METex20.chr7.116435941.116436178_tile_1	Human	hg19	chr7	116435941	116436178	+	TACAACCCGAATACTGCCCAGAC	AATGCTGGCACCCTAAAGCCGAAAT	+
METex20.chr7.116435941.116436178_tile_2	Human	hg19	chr7	116435941	116436178	-	GATACGGAGCGACACATTTTACGTTC	GCATTACTTCATATCTGTTCCAAAAAGAA	-
METex20.chr7.116435941.116436178_tile_3	Human	hg19	chr7	116435941	116436178	+	ACTATGTCCATGTGAACGCTACTTATG	ACAGTCCACACTTTGTCCAATGGT	+
MSH6ex5.chr2.48030559.48030824_tile_1	Human	hg19	chr2	48030559	48030824	+	AGAAGACCTATAAAACACTTAGGCTGA	TAGAGCTTAAAGGATCACGCCATCCT	+
MSH6ex5.chr2.48030559.48030824_tile_2	Human	hg19	chr2	48030559	48030824	-	GCACACAATAGGCTTTGCCATTTTCC	AATTACTGGGCGACACATAGGACCAT	-
MSH6ex5.chr2.48030559.48030824_tile_3	Human	hg19	chr2	48030559	48030824	+	TTCTAATAGGCTGTGAGGAAGAGGAGC	TACTTAGGTGATCATTTTCCAAACACAG	+
NRASex1.chr1.115258688.115258798_tile_1	Human	hg19	chr1	115258688	115258798	+	GGGCTACCACTGGGCCTCACCTCTAT	GAAACCAGTAATCAGGGTTAATTGGCG	+
NRASex2.chr1.115256401.115256619_tile_2	Human	hg19	chr1	115256401	115256619	-	AGACCAATACATGAGGACAGGCGAAGG	GAAATGAGGTTACCACACTAGGGAAGAT	-
NRASex2.chr1.115256401.115256619_tile_3	Human	hg19	chr1	115256401	115256619	+	ATCCGCAAATGACTTGCTATTATTGATGG	ACCACTTGTTTTCTGTAAGAATCCTGGG	+
NRASex2.chr1.115256401.115256619_tile_4	Human	hg19	chr1	115256401	115256619	-	GCAGAAATGGGCTTGAATAGTTAGATGC	GAAACCTGTTTGTTGGACATACTGGATA	-
NRASex3.chr1.115252190.115252349_tile_1	Human	hg19	chr1	115252190	115252349	+	ATGCATAACAACAAAGAATATGAATATGGA	CTTGGCCAGTTCGTGGGCTTGTTTTGTAT	+
NRASex3.chr1.115252190.115252349_tile_2	Human	hg19	chr1	115252190	115252349	-	CCAGCCTAATCTTGTTTTTCTTATGTTCTG	GTTACGGGATTCCATTCATTGAAACCT	-
NRASex4.chr1.115251152.115251275_tile_1	Human	hg19	chr1	115251152	115251275	+	GAAAATGTGCAGAAGAGGATAGGCAG	CATGGCAATCCCATACAACCCTGAGT	+
NRASex4.chr1.115251152.115251275_tile_2	Human	hg19	chr1	115251152	115251275	-	ATTGTGTCCGTTGAGCTAGCTCTC	GTGGTGATGTAACAAGGTGAGCATATG	-
PDGFRAex11.chr4.55141008.55141140_tile_1	Human	hg19	chr4	55141008	55141140	+	CAGCAATTACATGTGGAGTGAACGTTG	ATTCGCTGGAGGGTCATTGAATCAATC	+
PDGFRAex11.chr4.55141008.55141140_tile_2	Human	hg19	chr4	55141008	55141140	-	AAAAGGGAGTCTTGGGAGGTTACCCCATG	TCATACCTCGGTTTCTATAAATGACCA	-
PDGFRAex13.chr4.55144063.55144173_tile_1	Human	hg19	chr4	55144063	55144173	+	CAGCTGGACTGATATGTGATTTATTCT	AGTGAGGATTTTCACTGGACACATGTG	+
PDGFRAex17.chr4.55152008.55152130_tile_1	Human	hg19	chr4	55152008	55152130	+	GCCCTTTATATCCAGGCAGACAGCT	GCAACGTCCTCCTGGCACAAGGAAAAATT	+
PDGFRAex17.chr4.55152008.55152130_tile_2	Human	hg19	chr4	55152008	55152130	-	CACCTGACTTTAGAGATTAAAGTGAAGGA	AGCAGCCAGATCACGGTGGACAC	-
PIK3CAex1.chr3.178916648.178916965_tile_1	Human	hg19	chr3	178916648	178916965	+	TTCCTTCTTTGATTTAGGTTTCTGCTTTGG	GCCCCCAAGAATCCTAGTAGAATGTT	+
PIK3CAex1.chr3.178916648.178916965_tile_2	Human	hg19	chr3	178916648	178916965	-	GGGGTATTTTCTTGCTTCTTTAAATAGTTC	TTCACCTGATGATGGTCGTGGAGGCA	-
PIK3CAex1.chr3.178916648.178916965_tile_3	Human	hg19	chr3	178916648	178916965	+	TCCGTGAGGCTACATTAATAACCATAAAGC	TTTTGATGAAACAAGACGACTTTGTGACC	+
PIK3CAex1.chr3.178916648.178916965_tile_4	Human	hg19	chr3	178916648	178916965	-	GGACAACAGTTAAGCTTTATGGTTATTTGC	ATTCTTCCCTTTCTGCTTCTTGAGTAA	-
PIK3CAex2.chr3.178917478.178917687_tile_1	Human	hg19	chr3	178917478	178917687	+	TTACTTTATTGTGATCTTCCAAATCTACAG	AATTTGATATGGTTAAAGATCCAGAAGTAC	+
PIK3CAex2.chr3.178917478.178917687_tile_2	Human	hg19	chr3	178917478	178917687	-	GAAGATTCTACATTTGGAGGATAGACATAC	CTGGCATGCCGATAGCAAAACCTTTA	-
PIK3CAex2.chr3.178917478.178917687_tile_3	Human	hg19	chr3	178917478	178917687	+	ACCTCAATTCACCTCATAGTAGAGCAA	TTCTACCTGTGTCTATATCTTTGTATAGTC	+
PIK3CAex7.chr3.178927974.178928126_tile_1	Human	hg19	chr3	178927974	178928126	+	ATAGAGATGATTGTTGAATTTTCCTTTTGG	ACACAGACACTCTAGTATCTGGAAAAATGG	+
PIK3CAex7.chr3.178927974.178928126_tile_2	Human	hg19	chr3	178927974	178928126	-	AGAGAGAAGGTTTGACTGCCATAAAAA	ATCAAACAAGTTTATATTTCCCCATGC	-
PIK3CAex9.chr3.178935998.178936122_tile_2	Human	hg19	chr3	178935998	178936122	-	CATGCTGAGATCAGCCAAATTCAGT	GTCATTTTCCCTTAATTCATTGTCTCTAG	-
PIK3CAex9_OT.chr22.17052960.17053096_tile_2	Human	hg19	chr22	17052960	17053096	-	CATGCTGAGATCAGCCAAATTCAGT	GTCATTTTCCCTTAATTCATTGTCTCTAG	-
PIK3CAex20.chr3.178951882.178952152_tile_1	Human	hg19	chr3	178951882	178952152	+	TTTTTATAGCTTTGTCTACGAAAGCCTCTC	TATCTAGCTATTCGACAGCATGCCAATC	+
PIK3CAex20.chr3.178951882.178952152_tile_2	Human	hg19	chr3	178951882	178952152	-	CTTTCGAATGTATGCAATGTCATCAAAAG	CCTATAAGTAATAAGAACAGTTTGGTCAGT	-
PIK3CAex20.chr3.178951882.178952152_tile_3	Human	hg19	chr3	178951882	178952152	+	CATAAATCTTTTCTCAATGATGCTTGGCTC	CATGGTGGCTGGACAACAAAAATGGA	+
PIK3CAex20.chr3.178951882.178952152_tile_4	Human	hg19	chr3	178951882	178952152	-	CAATTCCTATGCAATCGGTCTTTGCCT	TGTGCATCATTCATTTGTTTCATGAAATA	-
PTENex1.chr10.89624227.89624305_tile_1	Human	hg19	chr10	89624227	89624305	+	TCCTCCTTTTTCTTCAGCCACAGG	ACCTTTCTGTCACTCTCTTAGAACGTG	+
PTENex1_OT.chr9.33676536.33676658 _tile_1	Human	hg19	chr9	33676536	33676658	-	TCCTCCTTTTTCTTCAGCCACAGG	GCAGAAAGACTTGAAGGCGTATACAG	-
PTENex2.chr10.89653782.89653866_tile_1	Human	hg19	chr10	89653782	89653866	+	CCACCTTTTATTACTCCAGCTATAGTGGG	GCAGAAAGACTTGAAGGCGTATACAG	+
PTENex2.chr10.89653782.89653866_tile_2	Human	hg19	chr10	89653782	89653866	-	CACAAAGTATCTTTTTCTGTGGCTTAG	GGAAATCCCATAGCAATAATGTTTGGATA	-
PTENex3.chr10.89685270.89685314_tile_1	Human	hg19	chr10	89685270	89685314	+	GTGGCTTTTTGTTTGTTTGTTTTGTTT	ATCTGCTTGTTAGAGTGAGGTAGAGTT	+
PTENex4.chr10.89690803.89690846_tile_1	Human	hg19	chr10	89690803	89690846	+	TCCTAAGTGCAAAAGATAACTTTATATCAC	TGAGTCATCCAGATTATCGAGTGAGAT	+
PTENex5.chr10.89692770.89693008_tile_1	Human	hg19	chr10	89692770	89693008	+	CTCTGGAATCCAGTGTTTCTTTTAAATACC	TTTTGAAGACCATAACCCACCACAGC	+
PTENex5.chr10.89692770.89693008_tile_2	Human	hg19	chr10	89692770	89693008	-	TCGTCCCTTTCCAGCTTTACAGTGAA	CTGTGGTAAAAAGATAACCTCAGAATAAG	-
PTENex5.chr10.89692770.89693008_tile_3	Human	hg19	chr10	89692770	89693008	+	TGAAGATGACAATCATGTTGCAGCA	TTGATGTTTTTCCTTTCCTCTTCCTGG	+
PTENex5_OT.chr9.33676091.33676311_tile_3	Human	hg19	chr9	33676121	33676287	-	TGAAGATGACAATCATGTTGCAGCA	ACTATAGCTACCTGGTAAAGAATCATGTGG	-
PTENex6.chr10.89711875.89712016_tile_1	Human	hg19	chr10	89711875	89712016	+	AATGTATATATGTTCTTAAATGGCTACGAC	ATTATAGCTACCTGTTAAAGAATCATCTGG	+
PTENex6.chr10.89711875.89712016_tile_2	Human	hg19	chr10	89711875	89712016	-	CTGTTCCAATACATGGAAGGATGAGAAT	ATACACATAGCGCCTCTGACTGGGAAT	-
PTENex6_OT.chr9.33675905.33676121_tile_2	Human	hg19	chr9	33675905	33676121	+	GGAAGAACTCTACTTTGATATCACCACACA	ATACACATAGCGCCTCTGACTGGGAAT	+
PTENex7.chr10.89717610.89717776_tile_1	Human	hg19	chr10	89717610	89717776	+	AAGATTGCAGATACAGAATCCATATTTCG	GTGGTCTGCCAGCTAAAGGTGAAGATA	+
PTENex7.chr10.89717610.89717776_tile_2	Human	hg19	chr10	89717610	89717776	-	GGAAGAACTCTACTTTGATATCACCACACA	GATCTGCATGGTTAAATACATACCAGTATT	-
PTENex7.chr10.89717610.89717776_tile_3	Human	hg19	chr10	89717610	89717776	+	TTGAGTTCCCTCAGCCGTTACCT	TAATTTGTTTTCTATTAGATCTGCAGGTG	+
PTENex9.chr10.89725044.89725229_tile_2	Human	hg19	chr10	89725044	89725229	-	TGGATCAGAGTCAGTGGTGTCAGAAT	GAGAAAGAAAATTTAAAATGAAAACCCACA	-
SMAD4ex8.chr18.48591793.48591976_tile_1	Human	hg19	chr18	48591793	48591976	+	GTGCATTACATTTCCATCTCCCCTC	GTGTTCCATTGCTTACTTTGAAATGGATG	+
SMAD4ex8.chr18.48591793.48591976_tile_2	Human	hg19	chr18	48591793	48591976	-	AAACAAAAGCGATCTCCTCCAGAAGGG	GCTATAGGAAATAAATGGGAAAGAACATCC	-
SMAD4ex8.chr18.48591793.48591976_tile_3	Human	hg19	chr18	48591793	48591976	+	CCCTATTGTTACTGTTGATGGATACGTGG	TTATTCAAGGTTATGTTTTCCCATGTAC	+
SMAD4ex11.chr18.48604626.48604837_tile_2	Human	hg19	chr18	48604626	48604837	-	CCAGCAAGGTGTTTCTTTGATGCT	ATTTGGAAGACATCAGAGGGACAGGGTGA	-
SMAD4ex11.chr18.48604626.48604837_tile_3	Human	hg19	chr18	48604626	48604837	+	AGGCTGGGGACCGGATTACCCAAGACA	TTAACCTTATCAGGATGGTGGACTACA	+
SRCex10.chr20.36031654.36031785_tile_1	Human	hg19	chr20	36031654	36031785	+	TCGCTCTGCCCACAGGGATGGTGAA	GAGGACTACTTCACGTCCACCGA	+
SRCex10.chr20.36031654.36031785_tile_2	Human	hg19	chr20	36031654	36031785	-	AATTCAGCCCCACAGAGAGAGGACCAACAG	AGGAAGGCCTGCAGGTACTCGAA	-
STK11ex1.chr19.1206913.1207202_tile_1	Human	hg19	chr19	1206913	1207202	+	TTTTCTTTGTAAAATTTTGGAGAAGGGAAG	CACGGAGGGCGAGCTGATGTCGGTGGGTAT	+
STK11ex1.chr19.1206913.1207202_tile_2	Human	hg19	chr19	1206913	1207202	-	ATCAGGTACTTGCCGATGAGCTTGGCC	TCCATGCTGGACCCAGGGTCCT	-
STK11ex1.chr19.1206913.1207202_tile_3	Human	hg19	chr19	1206913	1207202	+	AGGTCATCTACCAGCCGCGCCGCAA	CTCAAGAAGAAGAAGTTGCGAAGGATC	+
STK11ex4.chr19.1220372.1220504_tile_1	Human	hg19	chr19	1220372	1220504	+	CTGGACTTCTGTGACTTCCCAGCT	AGTACCTGCATAGCCAGGGCATT	+
STK11ex6.chr19.1221212.1221339_tile_2	Human	hg19	chr19	1221212	1221339	-	GGCTGCGGGCAGAGGGATGAGG	ATGTTGTAGCTTCATTTCGAGGGGAG	-
STK11ex8.chr19.1222984.1223171_tile_1	Human	hg19	chr19	1222984	1223171	+	AGCTGGGTCGGAAAACTGGACC	ACTGTGGTGCCGTACTTGGAGGA	+
STK11ex8.chr19.1222984.1223171_tile_2	Human	hg19	chr19	1222984	1223171	-	GACATCCTGGCCGAGTCAGCAG	ATGCTGCGCCACCGGTCCTTGGTGTCT	-
TP53ex2ex3ex4.chr17.7579241.7580010_tile_3	Human	hg19	chr17	7579241	7580010	+	CCAAAGTTCCAAACAAAAGAAATGCAGG	CCCTGGTAGGTTTTCTGGGAAGGGACA	+
TP53ex2ex3ex4.chr17.7579241.7580010_tile_4	Human	hg19	chr17	7579241	7580010	-	CCAGAATGCCAGAGGCTGCTCC	TTCTTGCATTCTGGGACAGCCAAG	-
TP53ex2ex3ex4.chr17.7579241.7580010_tile_5	Human	hg19	chr17	7579241	7580010	+	GTGTAGGAGCTGCTGGTGCAGG	GGGACTGTAGATGGGTGAAAAGAGCA	+
TP53ex2ex3ex4.chr17.7579241.7580010_tile_7	Human	hg19	chr17	7579241	7580010	+	TCCAGGTCCCCAGCCCAACCCTTGTCCTTA	CCTGCCCTTCCAATGGATCCACTCACA	+
TP53ex2ex3ex4.chr17.7579241.7580010_tile_8	Human	hg19	chr17	7579241	7580010	-	AGACTGCCTTCCGGGTCACTGCCAT	CCCCTAGCAGAGACCTGTGGGA	-
TP53ex2ex3ex4.chr17.7579241.7580010_tile_9	Human	hg19	chr17	7579241	7580010	+	GCTCGACGCTAGGATCTGACTG	GTGTCTGAGACAGCTCGGCTTCCTGT	+
TP53ex5TP53ex6.chr17.7578157.7578574_tile_2	Human	hg19	chr17	7578157	7578574	-	TCTTAGGTCTGGCCCCTCCTCAGCAT	TTAAGGGTGGTTGTCAGTGGCCCT	-
TP53ex5TP53ex6.chr17.7578157.7578574_tile_3	Human	hg19	chr17	7578157	7578574	+	CACGCAAATTTCCTTCCACTCGGATA	CCTCACAACCTCCGTCATGTGCTGTGA	+
TP53ex5TP53ex6.chr17.7578157.7578574_tile_4	Human	hg19	chr17	7578157	7578574	-	AACTGGCCAAGACCTGCCCTGTGCAG	ATAGCGATGGTGAGCAGCTGGGGCTG	-
TP53ex5TP53ex6.chr17.7578157.7578574_tile_5	Human	hg19	chr17	7578157	7578574	+	CGGGGGTGTGGAATCAACCCACA	CAGCAAAGAAACAAACATGCGTAAGC	+
TP53ex7.chr17.7577498.7577608_tile_1	Human	hg19	chr17	7577498	7577608	+	GTGCAGGGTGGCAAGTGGCTCCTGA	GCCCAAGATGAGGCCAGTGCGCCTT	+
TP53ex8TP53ex9.chr17.7576833.7577175_tile_2	Human	hg19	chr17	7576833	7577175	-	TGCCTCAGATTCACTTTTATCACCTTT	CTCTTATCAAGTGGAAAGTTTCCAGTCTAA	-
TP53ex8TP53ex9.chr17.7576833.7577175_tile_3	Human	hg19	chr17	7576833	7577175	+	TGGGCAGTGCTAGGAAAGAGGCAA	TCTTCCTCTGTGCGCCGGTCTCT	+
TP53ex8TP53ex9.chr17.7576833.7577175_tile_4	Human	hg19	chr17	7576833	7577175	-	AAATGGGACAGGTAGGACCTGATT	AATCTCCGCAAGAAAGGGGAGCCTCAC	-
TP53ex10.chr17.7573926.7574033_tile_1	Human	hg19	chr17	7573926	7574033	+	GGCTTTCCAACCTAGGAAGGCAG	CAGCAACAGAGGAGGGGGAGAAGTAA	+
TP53ex11.chr17.7572907.7573028_tile_1	Human	hg19	chr17	7572907	7573028	+	ATGGGGGTGGGAGGCTGTCAGT	GAGGAGAGATGACATCACATGAGTGAG	+
[Targets]									
TargetA	TargetB	Target Number	Species	Build ID	Chromosome	Start Position	End Position	Probe Strand	Sequence
AKT1ex2.chr14.105246425.105246553_tile_1	AKT1ex2.chr14.105246425.105246553_tile_1	1	Human	hg19	chr14	105246402	105246591	-	CCGCACGTCTGTAGGGGAGTACATCAAGACCTGGCGGCCACGCTACTTCCTCCTCAAGAATGATGGCACCTTCATTGGCTACAAGGAGCGGCCGCAGGATGTGGACCAACGTGAGGCTCCCCTCAACAACTTCTCTGTGGCGC
ALKex23.chr2.29443572.29443701_tile_2	ALKex23.chr2.29443572.29443701_tile_2	1	Human	hg19	chr2	29443619	29443802	+	CGGGGCAGGGATTGCAGGCTCACCCCAATGCAGCGAACAATGTTCTGGTGGTTGAATTTGCTGCAGAGCAGAGAGGGATGTAACCAAAATTAACTGAGCTGAGTCTGGGCAAATCTTAAACTGGGAGGAACAG
APCex15_1.chr5.112173836.112173974_tile_1	APCex15_1.chr5.112173836.112173974_tile_1	1	Human	hg19	chr5	112173713	112173892	-	CAATTCCGCGTTCTCTCTCCAAACTTCTATCTTTTTCAGAACGAGAACTATCTAAGCTTCCTCTTGATGAAGAGGAGCTGGGTAACACTGTAGTATTCAAATATGGTGAAAGGACAGTCATGTT
APCex15_1.chr5.112173836.112173974_tile_2	APCex15_1.chr5.112173836.112173974_tile_2	1	Human	hg19	chr5	112173843	112174013	+	GGTCTAGGCAACTACCATCCAGCAACAGAAAATCCAGGAACTTCTTCAAAGCGAGGTTTGCAGATCTCCACCACTGCAGCCCAGATTGCCAAAGTCATGGAAGAAGTGTCAGCCATTCATACC
APCex15_2.chr5.112174625.112174757_tile_1	APCex15_2.chr5.112174625.112174757_tile_1	1	Human	hg19	chr5	112174497	112174680	-	CCATGATTAGAACCCACTCGATTTGTTTCTGAACCATTGGCTCCCCGTGACCTGTATGGAGAAACACATTCCTGCTGTCCAAAATGTGGTTGGAACTTGAGGTGTTTATCATCAGTGCTCTCAGT
APCex15_2.chr5.112174625.112174757_tile_2	APCex15_2.chr5.112174625.112174757_tile_2	1	Human	hg19	chr5	112174621	112174808	+	GAATTAATCAAAATGTAAGCCAGTCTTTGTGTCAAGAAGATGACTATGAAGATGATAAGCCTACCAATTATAGTGAACGTTACTCTGAAGAAGAACAGCATGAAGAAGAAGAGAGACCAACAAATTATA
APCex15_3.chr5.112174992.112176072_tile_2	APCex15_3.chr5.112174992.112176072_tile_2	1	Human	hg19	chr5	112174949	112175113	+	GAATCAGCTCCATCCAAGTTCTGCACAGAGTAGAAGTGGTCAGCCTCAAAAGGCTGCCACTTGCAAAGTTTCTTCTATTAACCAAGAAACAATACAGACTTATTGTGTAG
APCex15_3.chr5.112174992.112176072_tile_3	APCex15_3.chr5.112174992.112176072_tile_3	1	Human	hg19	chr5	112175037	112175204	-	TTCCTGTGTCGTCTGATTACATCCTATTTCATCTTCAGCTGATGACAAAGATGATAATGAACTACATCTTGAAAAACATATTGGAGTATCTTCTACACAATAAGTCTGTAT
APCex15_3.chr5.112174992.112176072_tile_4	APCex15_3.chr5.112174992.112176072_tile_4	1	Human	hg19	chr5	112175127	112175291	+	ATGTAATCAGACGACACAGGAAGCAGATTCTGCTAATACCCTGCAAATAGCAGAAATAAAAGAAAAGATTGGAACTAGGTCAGCTGAAGATCCTGTGAGCGAAGTTCC
APCex15_3.chr5.112174992.112176072_tile_5	APCex15_3.chr5.112174992.112176072_tile_5	1	Human	hg19	chr5	112175227	112175393	-	GATTTCGCTCCTGAAGAAAATTCAACAGCTTTGTGCCTGGCTGATTCTGAAGATAAACTAGAACCCTGCAGTCTGCTGGATTTGGTTCTAGGGTGCTGTGACACTGCTGGAACTTCGC
APCex15_3.chr5.112174992.112176072_tile_7	APCex15_3.chr5.112174992.112176072_tile_7	1	Human	hg19	chr5	112175441	112175608	-	TGGTTTGTCCAGGGCTATCTGGAAGATCACTGGGGCTTATAATGCCACTTACCATTCCACTGCATGGTTCACTCTGAACGGAGCTGGCAATCGAACGACTCTCAAAACTATCAA
APCex15_3.chr5.112174992.112176072_tile_8	APCex15_3.chr5.112174992.112176072_tile_8	1	Human	hg19	chr5	112175549	112175715	+	GGACAAACCATGCCACCAAGCAGAAGTAAAACACCTCCACCACCTCCTCAAACAGCTCAAACCAAGCGAGAAGTACCTAAAAATAAAGCACCTACTGCTGAAAAGAGAGAGAGTGGACCT
APCex15_3.chr5.112174992.112176072_tile_9	APCex15_3.chr5.112174992.112176072_tile_9	1	Human	hg19	chr5	112175655	112175819	-	CAAGAAAATCCATCTGGAGTACTTTCCGTGGCAAAATGTAATAAAGTATCAGCATCTGGAAGAACCTGGACCCTCTGAACTGCAGCATTTACTGCAGCTTGCTTAGGTCCACTCT
APCex15_3.chr5.112174992.112176072_tile_10	APCex15_3.chr5.112174992.112176072_tile_10	1	Human	hg19	chr5	112175761	112175927	+	GATTTTCTTGTTCATCCAGCCTGAGTGCTCTGAGCCTCGATGAGCCATTTATACAGAAAGATGTGGAATTAAGAATAATGCCTCCAGTTCAGGAAAATGACAATGGGAATGAAA
APCex15_3.chr5.112174992.112176072_tile_11	APCex15_3.chr5.112174992.112176072_tile_11	1	Human	hg19	chr5	112175869	112176042	-	ATTTCAATATCATCATCATCTGAATCATCTAATAGGTCCTTTTCAGAATCAATAGTTTTTTCTGCCTCTTTCTCTTGGTTTTCATTTGATTCTTTAGGCTGCTCTGATTCTGTTTCAT
APCex15_3.chr5.112174992.112176072_tile_12	APCex15_3.chr5.112174992.112176072_tile_12	1	Human	hg19	chr5	112175973	112176160	+	ATATTGAAATACTAGAAGAATGTATTATTTCTGCCATGCCAACAAAGTCATCACGTAAAGCAAAAAAGCCAGCCCAGACTGCTTCAAAATTACCTCCACCTGTGGCAAGGAAACCAAGTCAGCTGCCT
BRAFex11.chr7.140481376.140481493_tile_1	BRAFex11.chr7.140481376.140481493_tile_1	1	Human	hg19	chr7	140481247	140481412	-	AGTGGCATGGTAAGTATGTAATGTGGTGACATTGTGACAAGTCATAATAGGATATGTTTAACAACTTTTATTTTGTAAAAAATATCATCAAAGGAAATATTCACTGTT
BRAFex11.chr7.140481376.140481493_tile_2	BRAFex11.chr7.140481376.140481493_tile_2	1	Human	hg19	chr7	140481357	140481547	+	TTTCCCTTGTAGACTGTTCCAAATGATCCAGATCCAATTCTTTGTCCCACTGTAATCTGCCCATCAGGAATCTCCCAATCATCACTCGAGTCCCGTCTACCAAGTGTTTTCTTGATAAAAACAGTAAAAAAGTCAAG
BRAFex15.chr7.140453075.140453193_tile_1	BRAFex15.chr7.140453075.140453193_tile_1	1	Human	hg19	chr7	140453044	140453222	-	AGATATATTTCTTCATGAAGACCTCACAGTAAAAATAGGTGATTTTGGTCTAGCTACAGTGAAATCTCGATGGAGTGGGTCCCATCAGTTTGAACAGTTGTCTGGATCCATTTTGTGGATGGTA
CDH1ex8.chr16.68846038.68846166_tile_1	CDH1ex8.chr16.68846038.68846166_tile_1	1	Human	hg19	chr16	68845915	68846082	-	CAGGGTATACGTAGGGAAACTCTGCAGAGAGATCGACACAACCAAGTCAGGACCAGGAACACTAGCCACCTTTGGCCTAGCCCAGCCCAACACATGGAACCAGAATATTTAACCATGTGC
CDH1ex8.chr16.68846038.68846166_tile_2	CDH1ex8.chr16.68846038.68846166_tile_2	1	Human	hg19	chr16	68846033	68846204	+	GGTGGTTCAAGCTGCTGACCTTCAAGGTGAGGGGTTAAGCACAACAGCAACAGCTGTGATCACAGTCACTGACACCAACGATAATCCTCCGATCTTCAATCCCACCACGGTAATTCTAT
CDH1ex9.chr16.68847216.68847398_tile_2	CDH1ex9.chr16.68847216.68847398_tile_2	1	Human	hg19	chr16	68847183	68847355	+	CAGTACAAGGGTCAGGTGCCTGAGAACGAGGCTAACGTCGTAATCACCACACTGAAAGTGACTGATGCTGATGCCCCCAATACCCCAGCGTGGGAGGCTGTATACACCATATTGAA
CDH1ex9.chr16.68847216.68847398_tile_3	CDH1ex9.chr16.68847216.68847398_tile_3	1	Human	hg19	chr16	68847301	68847489	-	GGGACAAGGGTATGAACAGCTGTGAGGATGCCAGTTTCTGCATCTTGCCAGGTACCATACAAACCTTTGCTGTTTTCAAAATGCCATCGTTGTTCACTGGATTTGTGGTGACGACAAATTGTCCACCATCATCAT
CDH1ex12.chr16.68855904.68856128_tile_2	CDH1ex12.chr16.68855904.68856128_tile_2	1	Human	hg19	chr16	68855871	68856035	+	TCTTAGGTTCTCCAGTTGCTACTGGAACAGGGACACTTCTGCTGATCCTGTCTGATGTGAATGACAACGCCCCCATACCAGAACCTCGAACTATATTCTTCTGTGAGAGGA
CDH1ex12.chr16.68855904.68856128_tile_3	CDH1ex12.chr16.68855904.68856128_tile_3	1	Human	hg19	chr16	68855981	68856156	-	TTGGGTCGTTGTACTGAATGGTCCAGTTGGCACTCGCCCCGTGTGTTAGTTCTGCTGTGAAGGGAGATGTATTGGGAGGAAGGTCTGCATCAATGATGTTTATGACCTGAGGCTTTGGATT
CTNNB1ex2.chr3.41266017.41266151_tile_1	CTNNB1ex2.chr3.41266017.41266151_tile_1	1	Human	hg19	chr3	41265892	41266060	-	ACTCCATCAAATCAGCTATAAATACGAAACAGTATTAGCATTAGTAGATTGGAAATGTTACTTTAATTTAAAAAAAAAGAATCTGTGATATGACCCATTGAAATATTTTTA
CTNNB1ex2.chr3.41266017.41266151_tile_2	CTNNB1ex2.chr3.41266017.41266151_tile_2	1	Human	hg19	chr3	41266002	41266186	+	TTGGACATGGCCATGGAACCAGACAGAAAAGCGGCTGTTAGTCACTGGCAGCAACAGTCTTACCTGGACTCTGGAATCCATTCTGGTGCCACTACCACAGCTCCTTCTCTGAGTGGTAAAGGCAATCCTGA
EGFRex18.chr7.55241613.55241736_tile_1	EGFRex18.chr7.55241613.55241736_tile_1	1	Human	hg19	chr7	55241536	55241703	-	CAAGATCCTCAAGAGAGCTTGGTTGGGAGCTTCTCCACTGGGTGTAAGAGGCTCCACAAGCTGGGGGGGACAAGAACACAGAGACAAGGGTCACCTCAGCCCTCACCATGCTGG
EGFRex18.chr7.55241613.55241736_tile_2	EGFRex18.chr7.55241613.55241736_tile_2	1	Human	hg19	chr7	55241646	55241828	+	GAAGGAAACTGAATTCAAAAAGATCAAAGTGCTGGGCTCCGGTGCGTTCGGCACGGTGTATAAGGTAAGGTCCCTGGCACAGGCCTCTGGGCTGGGCCGCAGGGCCTCTCATGGTCTGGTGGGGAGCCC
EGFRex19.chr7.55242414.55242513_tile_1	EGFRex19.chr7.55242414.55242513_tile_1	1	Human	hg19	chr7	55242385	55242576	-	GAGCCATGGACCCCCACACAGCAAAGCAGAAACTCACATCGAGGATTTCCTTGTTGGCTTTCGGAGATGTTGCTTCTCTTAATTCCTTGATAGCGACGGGAATTTTAACTTTCTCACCTTCTGGGATCCAGAGTCCCTA
EGFRex20.chr7.55248985.55249171_tile_1	EGFRex20.chr7.55248985.55249171_tile_1	1	Human	hg19	chr7	55248912	55249105	+	CTGGCCACCATGCGAAGCCACACTGACGTGCCTCTCCCTCCCTCCAGGAAGCCTACGTGATGGCCAGCGTGGACAACCCCCACGTGTGCCGCCTGCTGGGCATCTGCCTCACCTCCACCGTGCAGCTCATCACGCAG
EGFRex20.chr7.55248985.55249171_tile_2	EGFRex20.chr7.55248985.55249171_tile_2	1	Human	hg19	chr7	55249052	55249233	-	CCTTATCTCCCCTCCCCGTATCTCCCTTCCCTGATTACCTTTGCGATCTGCACACACCAGTTGAGCAGGTACTGGGAGCCAATATTGTCTTTGTGTTCCCGGACATAGTCCAGGAGGCAGCCGAAGGGCATGAGC
EGFRex21.chr7.55259411.55259567_tile_1	EGFRex21.chr7.55259411.55259567_tile_1	1	Human	hg19	chr7	55259320	55259514	-	GCGGTGTTTTCACCAGTACGTTCCTGGCTGCCAGGTCGCGGTGCACCAAGCGACGGTCCTCCAAGTAGTTCATGCCCTGAAACAGAGAAGACCCTGCTGTGAGGGACAGATCATCATGGGAAGAAGCTCTGCATCCGAATTCAGG
EGFRex21.chr7.55259411.55259567_tile_2	EGFRex21.chr7.55259411.55259567_tile_2	1	Human	hg19	chr7	55259464	55259650	+	CAGCATGTCAAGATCACAGATTTTGGGCTGGCCAAACTGCTGGGTGCGGAAGAGAAAGAATACCATGCAGAAGGAGGCAAAGTAAGGAGGTGGCTTTAGGTCAGCCAGCATTTTCCTGACACCAGGGACCAGGCTGC
ERBB2ex20.chr17.37880979.37881164_tile_2	ERBB2ex20.chr17.37880979.37881164_tile_2	1	Human	hg19	chr17	37880952	37881116	+	CCCAGGAAGCATACGTGATGGCTGGTGTGGGCTCCCCATATGTCTCCCGCCTTCTGGGCATCTGCCTGACATCCACGGTGCAGCTGGTGACACAGCTTATGCCCTATGGCTGCCTCTTAG
ERBB2ex20.chr17.37880979.37881164_tile_3	ERBB2ex20.chr17.37880979.37881164_tile_3	1	Human	hg19	chr17	37881066	37881239	-	TGGACATAGGGGTTTGCTCCGGAGAGACCTGCAAAGAGCCCAGGTGCATACCTTGGCAATCTGCATACACCAGTTCAGCAGGTCCTGGGAGCCCAGGCGTCCGCGGTTTTCCCGGACATGGTC
FBXW7ex7.chr4.153250824.153250937_tile_1	FBXW7ex7.chr4.153250824.153250937_tile_1	1	Human	hg19	chr4	153250697	153250862	-	TCACAGGCAAAGTAAGTTTACTCTTCCTACACTTCACAAAGTCATAATTTTGTGTATATCATTGCAAGTAGCAACTGGAAAAAAGAAAACAATAATTCATTTTTGATT
FBXW7ex7.chr4.153250824.153250937_tile_2	FBXW7ex7.chr4.153250824.153250937_tile_2	1	Human	hg19	chr4	153250807	153250972	+	ACTGCTGACCAAACTTTTAAAGTGTTGTCATCAGAACCACTAACTATTCGGTTACCACAAAACTGTAAGCATGTGATCACATGATCATCATGTCCTTTCAGCACCTATA
FBXW7ex8.chr4.153249360.153249541_tile_1	FBXW7ex8.chr4.153249360.153249541_tile_1	1	Human	hg19	chr4	153249245	153249411	-	GTTGTATGCATCTTCATGAAAAAAGGTAAGGGAAAATCTTGTCATGGTTGGGACTTCTTCCTCTATTATTGGTGAATTTGGGCCCTTTCTGTGTAGAGTTACTGAAATAG
FBXW7ex8.chr4.153249360.153249541_tile_2	FBXW7ex8.chr4.153249360.153249541_tile_2	1	Human	hg19	chr4	153249333	153249514	+	CTTTTTTCATGAAGATGCATACAACGCACAGTGGAAGTATGCCCATATAAGGTGTGTATACATTCTCCAGTCTCTGCATTCCACACTTTGAGTGTCCGATCTGTAGATCCACTAATGATGATGTTGT
FBXW7ex8.chr4.153249360.153249541_tile_3	FBXW7ex8.chr4.153249360.153249541_tile_3	1	Human	hg19	chr4	153249457	153249635	-	ATTAAATTTTATTTAAATCACTTTTCCTTTCTACCCAAAAGTAATCATCTTAAGTGTTTTTCCAGTGTCTGAGAACATTAGTGGGACATACAGGTGGAGTATGGTCATCACAAATGAGAGA
FBXW7ex9.chr4.153247158.153247383_tile_1	FBXW7ex9.chr4.153247158.153247383_tile_1	1	Human	hg19	chr4	153247057	153247221	-	GTTGCAGGGGCATACTAATAGAGTCTATTCATTACAGGTAAGATCTCTTATCTCTCCCTTAAATGCTCTCCTGATGAATCATAAGGTTGTTTTACTCAGATAATCACTGT
FBXW7ex9.chr4.153247158.153247383_tile_2	FBXW7ex9.chr4.153247158.153247383_tile_2	1	Human	hg19	chr4	153247157	153247333	+	CCTGCAACGTGTGTAGACAGGTTTCAGTCTCTGGATCCCACACCTTTACCATAAAATCATATGCTCCACTAACAACCCTCCTGCCATCATATTGAACACAGCGGACTGCTGCAACATGAC
FBXW7ex9.chr4.153247158.153247383_tile_3	FBXW7ex9.chr4.153247158.153247383_tile_3	1	Human	hg19	chr4	153247283	153247477	-	ATTATTAAAAATTCTAAACGTGGGTTTTTTTGTTTTGTTTTGTTTTTCTGTTTCTCCCTCTGCAGAGTTGTTAGCGGTTCTCGAGATGCCACTCTTAGGGTTTGGGATATTGAGACAGGCCAGTGTTTACATGTTTTGATGGG
FBXW7ex10.chr4.153245336.153245546_tile_2	FBXW7ex10.chr4.153245336.153245546_tile_2	1	Human	hg19	chr4	153245289	153245461	+	AGGTGAGTAAGACTTACCTTGCAATGTTTGTAAACACTGTCCTGTTTTGATATCCCAGATTTTAACTGTAGAATCTGCATTCCCAGAGACAAGAATATTGTCTTTGAGTTCCAT
FBXW7ex10.chr4.153245336.153245546_tile_3	FBXW7ex10.chr4.153245336.153245546_tile_3	1	Human	hg19	chr4	153245405	153245598	-	TAATAAACTGTGTCTTTTGTAGTTTGATGGTATCCATGTGGTGAGTGGATCTCTTGATACATCAATCCGTGTTTGGGATGTGGAGACAGGGAATTGCATTCACACGTTAACAGGGCACCAGTCGTTAACAAGTGGAA
FBXW7ex11.chr4.153244033.153244301_tile_1	FBXW7ex11.chr4.153244033.153244301_tile_1	1	Human	hg19	chr4	153243912	153244076	-	ATGTGGACATGAAGTGAAGAGCAGAAAAGATGAATTTGTCCAATTGTGTAGACGATATACTCCCTGCCCTTCCCCCTGCAAAAAGAAAAAAAGAAAAGAAAAAGAAAAAAATCCC
FBXW7ex11.chr4.153244033.153244301_tile_2	FBXW7ex11.chr4.153244033.153244301_tile_2	1	Human	hg19	chr4	153244022	153244215	+	ATCAAAGTCCAGCACCAGCAGCTTGGTTTCTTCAGTCCCATTCCGACTCCCAACTGCACACACCAGCTTTGTGTTTGAGGCTCTGATCCGCCACACAACTCCCCCACTCCCCCCACTCTCCAATGTGACTAGGTTTCGAA
FBXW7ex11.chr4.153244033.153244301_tile_3	FBXW7ex11.chr4.153244033.153244301_tile_3	1	Human	hg19	chr4	153244162	153244333	-	AGGTCCCAACAAGCATCAGAGTGCTGTGACCTGTTTACAGTTCAACAAGAACTTTGTAATTACCAGCTCAGATGATGGAACTGTAAAACTATGGGACTTGAAAACGGGTGAATTTAT
FGFR2ex6.chr10.123279493.123279683_tile_1	FGFR2ex6.chr10.123279493.123279683_tile_1	1	Human	hg19	chr10	123279400	123279593	-	GTGGATCAAGCACGTGGAAAAGAACGGCAGTAAATACGGGCCCGACGGGCTGCCCTACCTCAAGGTTCTCAAGGTGAGGACTTTCTGAATCTAAAGGTACCCACAACTGGGGTCTCCTTCATGGGTTTGGCCACAGGTT
FGFR2ex6.chr10.123279493.123279683_tile_2	FGFR2ex6.chr10.123279493.123279683_tile_2	1	Human	hg19	chr10	123279540	123279718	+	CTGGATGTGGGGCTGGGCATCACTGTAAACCTTGCAGACAAACTCTACGTCTCCTCCGACCACTGTGGAGGCATTTGCCGGCAGTCCGGCTTGGAGGATGGGCCGGTGAGGCGATCGCTCTGGTGGAGAGA
FOXL2ex1.chr3.138665113.138665213_tile_1	FOXL2ex1.chr3.138665113.138665213_tile_1	1	Human	hg19	chr3	138665082	138665248	-	TGCCGCGCGAGGGCGGCGGCGAGCGCAAGGGCAACTACTGGACGCTGGACCCGGCCTGCGAAGACATGTTCGAGAAGGGCAACTACCGGCGCCGCCGCCGCATGAAGAGGCCC
GNAQex4.chr9.80412436.80412564_tile_1	GNAQex4.chr9.80412436.80412564_tile_1	1	Human	hg19	chr9	80412315	80412480	-	TACAAAGTGTCATTTTCAGGTAGTAACTGAGTCCATGAAACCTATTTCCCAGCTTTTATGCCTTGAGTACATTTGGTAAACTCTATAAATACTGGAATCATGTGTAGGCT
GNAQex4.chr9.80412436.80412564_tile_2	GNAQex4.chr9.80412436.80412564_tile_2	1	Human	hg19	chr9	80412427	80412610	+	AAGTCAAAGGGGTATTCGATGATCCCTGTGGTGGGGACTCGAACTCTAAGCACATCTTGTTGCGTAGGCAGGTAGGCAGGGTCAGCTACGCGGTCCAAGTCATTAAGATAGCTAGAGGAGGGAAGACACAA
GNAQex5.chr9.80409379.80409508_tile_2	GNAQex5.chr9.80409379.80409508_tile_2	1	Human	hg19	chr9	80409332	80409500	+	GTCTAAAGAACACTTACCTCATTGTCTGACTCCACGAGAACTTGATCATATTCACTAAGCGCTACTAGAAACATGATAGAGGTGACATTTTCAAAGCAGTGTATCCATTTTCTTCT
GNAQex5.chr9.80409379.80409508_tile_3	GNAQex5.chr9.80409379.80409508_tile_3	1	Human	hg19	chr9	80409448	80409631	-	AATATTTTCCCTAAGTTTGTAAGTAGTGCTATATTTATGTTGACTTTTTAGTTTTACTTTATATGTTATTAATATGAGTATTGTTAACCTTGCAGAATGGTCGATGTAGGGGGCCAAAGGTCAGAGA
GNAQex6.chr9.80343430.80343583_tile_2	GNAQex6.chr9.80343430.80343583_tile_2	1	Human	hg19	chr9	80343399	80343585	+	CTTACCATCATATTCTGGGAAGTAGTCGACTAGATGGGAATACATGATTTTCTCCTCTAGAAGATCTTTCTTGTTTAAGAACAGAATAACCGAGGAGTTCTGGAACCAGGGGTATGTGATAATTGTTCTAAAGAGA
GNAQex6.chr9.80343430.80343583_tile_3	GNAQex6.chr9.80343430.80343583_tile_3	1	Human	hg19	chr9	80343531	80343718	-	TGGTCGTATACAAAAGATGGGTTGGACTTATAAAATAAACACAATTCACAAATTAAGTAATCATGTAATTCACTCCTTGTTTTTTCTGATTTTTTTTTTTTTTCCAGAACCGAATGGAGGAAAGCAAGGCT
GNASex6.chr20.57480438.57480535_tile_1	GNASex6.chr20.57480438.57480535_tile_1	1	Human	hg19	chr20	57480393	57480574	-	GGCGGTTACTTACTACTGGGCACAGTCAATCAGCTGGTACTCGTTGGAGCGTTCGTAGCAGGCACGCACTCCTTCATCCTCCCACAGAGCCTTGGCATGCTCATAGAATTCCTGAAAGTGAACACAAGA
GNASex8.chr20.57484405.57484478_tile_1	GNASex8.chr20.57484405.57484478_tile_1	1	Human	hg19	chr20	57484374	57484560	-	GTGAATGTCAAGAAACCATGATCTCTGTTATATAAAAAGGTAACAGTTGGCTTACTGGAAGTTGACTTTGTCCACCTGGAACTTGGTCTCAAAGATTCCAGAAGTCAGGACACGGCAGCGAAGCAGGTCCT
KITex9.chr4.55592023.55592216_tile_1	KITex9.chr4.55592023.55592216_tile_1	1	Human	hg19	chr4	55591894	55592064	-	AGAAGCAGAGCATCTAAAGGGAAGAAAACAAAAGCCCTGGCTTACTCTAGGAAAATAAATAAATACATAAAACACTTGGGATGTGGCATACTTTTAAAACAAAGTTAGAGGT
KITex9.chr4.55592023.55592216_tile_2	KITex9.chr4.55592023.55592216_tile_2	1	Human	hg19	chr4	55591998	55592172	+	CTCTGCTTCTGTACTGCCAGTGGATGTGCAGACACTAAACTCATCTGGGCCACCGTTTGGAAAGCTAGTGGTTCAGAGTTCTATAGATTCTAGTGCATTCAAGCACAATGGCACGGTTGAAT
KITex9.chr4.55592023.55592216_tile_3	KITex9.chr4.55592023.55592216_tile_3	1	Human	hg19	chr4	55592120	55592293	-	AGACAGAGCCTAAACATCCCCTTAAATTGGATTAAAAAGAAATATACCTTTGTTGTTACCTTTAAATGCAAAGTTAAAATAGGCAGAAGTCTTGCCCACATCGTTGTAAGCCTTACA
KITex11.chr4.55593581.55593708_tile_1	KITex11.chr4.55593581.55593708_tile_1	1	Human	hg19	chr4	55593460	55593628	-	TGTACTTCATACATGGGTTTCTGTGGGGAGAAAGGGAAAAATAGATCACCTTTTAATAATTATTGTCTCAGTCATTAGAGCACTCTGGAGAGAGAACAAATAAATGGTTACCT
KITex11.chr4.55593581.55593708_tile_2	KITex11.chr4.55593581.55593708_tile_2	1	Human	hg19	chr4	55593574	55593758	+	AGTGGAAGGTTGTTGAGGAGATAAATGGAAACAATTATGTTTACATAGACCCAACACAACTTCCTTATGATCACAAATGGGAGTTTCCCAGAAACAGGCTGAGTTTTGGTCAGTATGAAACAGGGGCTTTC
KITex13.chr4.55594176.55594287_tile_1	KITex13.chr4.55594176.55594287_tile_1	1	Human	hg19	chr4	55594147	55594325	-	CACGGCTTTACCTCCAATGGTGCAGGCTCCAAGTAGATTCACAATATTCATGTGATTACCAAGGTAACTCAGGACTTTGAGTTCAGACATGAGGGCTTCCCGTTCTGTCAAATGGGCACTCGCTA
KITex17.chr4.55599235.55599358_tile_1	KITex17.chr4.55599235.55599358_tile_1	1	Human	hg19	chr4	55599196	55599367	+	AACCTAATAGTGTATTCACAGAGACTTGGCAGCCAGAAATATCCTCCTTACTCATGGTCGGATCACAAAGATTTGTGATTTTGGTCTAGCCAGAGACATCAAGAATGATTCT
KITex17.chr4.55599235.55599358_tile_2	KITex17.chr4.55599235.55599358_tile_2	1	Human	hg19	chr4	55599310	55599494	-	TATCCCTAGACAGGATTTACATTATGAAAATCACAGGAAACAATTTTTATCGAAAGTTGAAACTAAAAATCCTTTGCAGGACTGTCAAGCAGAGAATGGGTACTCACGTTTCCTTTAACCACATAATTA
KITex18.chr4.55602664.55602775_tile_1	KITex18.chr4.55602664.55602775_tile_1	1	Human	hg19	chr4	55602633	55602811	-	TCATTTTACCTAAAGAGAACAGCTCCCAAAGAAAAATCCCATAGGACCAGACGTCACTTTCAAACGTGTATACACAGTTGAAAATGCTTTCAGGTGCCATCCACTTCACAGGTAGTCGAGCCT
KRASex1.chr12.25398208.25398329_tile_1	KRASex1.chr12.25398208.25398329_tile_1	1	Human	hg19	chr12	25398111	25398278	-	AGCTAATTCAGAATCATTTTGTGGACGAATATGATCCAACAATAGAGGTAAATCTTGTTTTAATATGCATATTACTGGTGCAGGACCATTCTTTGATACAGATAAAGGTTTCTCT
KRASex1.chr12.25398208.25398329_tile_2	KRASex1.chr12.25398208.25398329_tile_2	1	Human	hg19	chr12	25398225	25398414	+	TGTATCGTCAAGGCACTCTTGCCTACGCCACCAGCTCCAACTACCACAAGTTTATATTCAGTCATTTTCAGCAGGCCTTATAATAAAAATAATGAAAATGTGACTATATTAGAACATGTCACACATAAGGT
KRASex2.chr12.25380168.25380346_tile_1	KRASex2.chr12.25380168.25380346_tile_1	1	Human	hg19	chr12	25380075	25380260	-	GGGAGGGCTTTCTTTGTGTATTTGCCATAAATAATACTAAATCATTTGAAGATATTCACCATTATAGGTGGGTTTAAATTGAATATAATAAGCTGACATTAAGGAGTAATTATAGTTTTTATTTTTTGAG
KRASex2.chr12.25380168.25380346_tile_2	KRASex2.chr12.25380168.25380346_tile_2	1	Human	hg19	chr12	25380209	25380383	+	CCAGTCCTCATGTACTGGTCCCTCATTGCACTGTACTCCTCTTGACCTGCTGTGTCGAGAATATCCAAGAGACAGGTTTCTCCATCAATTACTACTTGCTTCCTGTAGGAATCCTGAGAAG
KRASex3.chr12.25378548.25378707_tile_1	KRASex3.chr12.25378548.25378707_tile_1	1	Human	hg19	chr12	25378449	25378614	-	ATGGAATTCCTTTTATTGAAACATCAGCAAAGACAAGACAGGTAAGTAACACTGAAATAAATACAGATCTGTTTTCTGCAAAATCATAACTGTTATGTCATTTAATATAT
KRASex3.chr12.25378548.25378707_tile_2	KRASex3.chr12.25378548.25378707_tile_2	1	Human	hg19	chr12	25378561	25378753	+	TAACTTCTTGCTAAGTCCTGAGCCTGTTTTGTGTCTACTGTTCTAGAAGGCAAATCACATTTATTTCCTACTAGGACCATAGGTACATCTTCAGAGTCCTTAACTCTTTTAATTTGTTCTCTGGGAAAGAAAAAAAA
KRASex4.chr12.25362729.25362845_tile_1	KRASex4.chr12.25362729.25362845_tile_1	1	Human	hg19	chr12	25362602	25362789	-	AAGAAGTCAAAGACAAAGTGTGTAATTATGTAAATACAATTTGTACTTTTTTCTTAAGGCATACTAGTACAAGTGGTAATTTTTGTACATTACACTAAATTATTAGCATTTGTTTTAGCATTACCTAATTTTT
KRASex4.chr12.25362729.25362845_tile_2	KRASex4.chr12.25362729.25362845_tile_2	1	Human	hg19	chr12	25362732	25362914	+	TTTTCTTCTTTTTACCATCTTTGCTCATCTTTTCTTTATGTTTTCGAATTTCTCGAACTAATGTATAGAAGGCATCATCAACACCCTGAAATACATAAAAAGTATTAAAATGTGAATATATACGATG
MAP2K1ex2.chr15.66727445.66727495_tile_1	MAP2K1ex2.chr15.66727445.66727495_tile_1	1	Human	hg19	chr15	66727410	66727588	-	CCAGGCCAGAAGGCTTGTGGGAGACCTTGAACACCACACCGCCATTGCCAGCCCCCAGCTCACTGATCTTCTCAAAGTCGTCATCCTTCAGTTCTCCCACCTTCTGCTTCTGGGTAAGAAAGGCC
METex1.chr7.116339642.116340262_tile_1	METex1.chr7.116339642.116340262_tile_1	1	Human	hg19	chr7	116339515	116339687	-	CAGGACACTGGCTGGGCTCTTCTATCTGTGGGGAGAATATGCAGTGAACCTCCGACTGTATGTCAGCAGTATGATTGTGGGGAAAGACATGTCGCTGGCAGGTCCCTCTGTTGACG
METex1.chr7.116339642.116340262_tile_2	METex1.chr7.116339642.116340262_tile_2	1	Human	hg19	chr7	116339607	116339772	+	GATAGAAGAGCCCAGCCAGTGTCCTGACTGTGTGGTGAGCGCCCTGGGAGCCAAAGTCCTTTCATCTGTAAAGGACCGGTTCATCAACTTCTTTGTAGGCAATACCATAA
METex1.chr7.116339642.116340262_tile_3	METex1.chr7.116339642.116340262_tile_3	1	Human	hg19	chr7	116339691	116339858	-	TCCGTCAAAAACATAAAACCATCTTTCGTTTCCTTTAGCCTTCTCACTGATATCGAATGCAATGGATGATCTGGGAAATAAGAAGAATTTATGGTATTGCCTACAAAGAAGTT
METex1.chr7.116339642.116340262_tile_4	METex1.chr7.116339642.116340262_tile_4	1	Human	hg19	chr7	116339799	116339965	+	GACCAGTCCTACATTGATGTTTTACCTGAGTTCAGAGATTCTTACCCCATTAAGTATGTCCATGCCTTTGAAAGCAACAATTTTATTTACTTCTTGACGGTCCAAAGGGA
METex1.chr7.116339642.116340262_tile_5	METex1.chr7.116339642.116340262_tile_5	1	Human	hg19	chr7	116339907	116340077	-	TCTCTTTTCTGTGAGAATACACTCCAGAGGCATTTCCATGTAGGAATGCAATCCAGAGTTTATGGAACAGAACCTGATTATTCTTGTGTGAAAAGTCTGAGCATCTAGAGTTTC
METex1.chr7.116339642.116340262_tile_6	METex1.chr7.116339642.116340262_tile_6	1	Human	hg19	chr7	116340023	116340203	+	AAAAAAGAGATCCACAAAGAAGGAAGTGTTTAATATACTTCAGGCTGCGTATGTCAGCAAGCCTGGGGCCCAGCTTGCTAGACAAATAGGAGCCAGCCTGAATGATGACATTCTTTTCGGGGTGTTCGC
METex1.chr7.116339642.116340262_tile_7	METex1.chr7.116339642.116340262_tile_7	1	Human	hg19	chr7	116340153	116340324	-	TGGAGACATCTCACATTGTTTTTGTTGACGATCTTGTTGAAGAAGTCGTTGACATATTTGATAGGGAATGCACACATGGCAGATCGATCCATTGGTTCGGCAGAATCTGGCTTGCTTTGTG
METex4.chr7.116380906.116381079_tile_1	METex4.chr7.116380906.116381079_tile_1	1	Human	hg19	chr7	116380777	116380946	-	TCAATGGGATCTTCGTGATCTGTGAAGAGAAGGGGTGGAAAGAGCTTCCAGAGGGGTATCTAGTTTGTTAATTAATTATAAAGTAAGTACACAAAAGGTACATGTAAATATCATTTGAT
METex4.chr7.116380906.116381079_tile_2	METex4.chr7.116380906.116381079_tile_2	1	Human	hg19	chr7	116380897	116381091	+	AATGGCTTGGGCTGCAGACATTTCCAGTCCTGCAGTCAATGCCTCTCTGCCCCACCCTTTGTTCAGTGTGGCTGGTGCCACGACAAATGTGTGCGATCGGAGGAATGCCTGAGCGGGACATGGACTCAACAGATCTGTCTG
METex4.chr7.116380906.116381079_tile_3	METex4.chr7.116380906.116381079_tile_3	1	Human	hg19	chr7	116381039	116381228	-	TAAATTTTTTTCATTAGTGGGATTTGTATCTAAAAAAACAAAAAACAAACCAAACCAAACCAAAAAAAAAAAAAAAACACCAAACAAAAACATGTATGCCAGCTGTTAGAGATTCCTACCTTGTAGATTGCAGGC
METex13.chr7.116411903.116412043_tile_2	METex13.chr7.116411903.116412043_tile_2	1	Human	hg19	chr7	116411868	116412034	+	TTTTAAGATCTGGGCAGTGAATTAGTTCGCTACGATGCAAGAGTACACACTCCTCATTTGGATAGGCTTGTAAGTGCCCGAAGTGTAAGCCCAACTACAGAAATGGTTTCAA
METex13.chr7.116411903.116412043_tile_3	METex13.chr7.116411903.116412043_tile_3	1	Human	hg19	chr7	116411980	116412173	-	TTTTTATAAAAATATAAATGCAAAACCAAAAATAAACAACAATGTCACAACCCACTGAGGTATATGTATAGGTATTTCTCAGAACAATAAACTGAAATATACCTTCTGGAAAAGTAGCTCGGTAGTCTACAGATTCATT
METex15.chr7.116417443.116417523_tile_1	METex15.chr7.116417443.116417523_tile_1	1	Human	hg19	chr7	116417414	116417586	-	AAAGTATACTCCATGGTTAAATAAAATGCCACTTACTGTTCAAGGATTTCACAGCACAGTGAATTTTCTTGCCATCATTGTCCAACAAAGTCCCATGATATACACAACCAAAATGCCCT
METex16.chr7.116418830.116419011_tile_2	METex16.chr7.116418830.116419011_tile_2	1	Human	hg19	chr7	116418783	116418948	+	ACCACTGGATTTCTCAGGAATCACTGACATAGGAGAAGTTTCCCAATTTCTGACCGAGGGAATCATCATGAAAGATTTTAGTCATCCCAATGTCCTCTCGCTCCTGGGAATCTG
METex16.chr7.116418830.116419011_tile_3	METex16.chr7.116418830.116419011_tile_3	1	Human	hg19	chr7	116418903	116419093	-	TGAAGGGATGGCTGGCTTACAGCTAGTTTGCCAGTTAGTAAGCTTGGCAGTCAACTTACATGAGTCTCATTTCGAATGAAATTTCGAAGATCTCCATGTTTCATGTATGGTAGGACCACCAGCGGAGACCCTTCACTTCGCAGGC
METex17.chr7.116422042.116422151_tile_1	METex17.chr7.116422042.116422151_tile_1	1	Human	hg19	chr7	116421913	116422096	-	AAGCCAATAAGATCTTTTACAGTTGGATTCTGCAGTCAAAGAGAGTTAGAAAAGCATAAACTAAGCATCTACTGTTCTAATTTTGACCTTAGAATTCTGAAATATTTATTTATAAAAAATTATCTTGT
METex17.chr7.116422042.116422151_tile_2	METex17.chr7.116422042.116422151_tile_2	1	Human	hg19	chr7	116422043	116422224	+	TTGGTCTTCAAGTAGCCAAAGGCATGAAATATCTTGCAAGCAAAAAGTTTGTCCACAGAGACTTGGCTGCAAGAAACTGTATGTAAGTATCAGAATCTCTGTGCCACAATCCAAATTAAGTGACAAGGA
METex18.chr7.116423358.116423523_tile_1	METex18.chr7.116423358.116423523_tile_1	1	Human	hg19	chr7	116423229	116423416	-	AGCAACCTTGACTGTGAATTTTTCATCCAGCCTACAGAAAGGACAAAAATTATTACCCGTGGCTGAAATAGAATAATTTACAATGATGCTGAATATCTACAGATTAAACAAGTGGCTTCAGTATTTGAAAT
METex18.chr7.116423358.116423523_tile_2	METex18.chr7.116423358.116423523_tile_2	1	Human	hg19	chr7	116423361	116423555	+	TGATTTTGGTCTTGCCAGAGACATGTATGATAAAGAATACTATAGTGTACACAACAAAACAGGTGCAAAGCTGCCAGTGAAGTGGATGGCTTTGGAAAGTCTGCAAACTCAAAAGTTTACCACCAAGTCAGATGTGGTA
METex20.chr7.116435941.116436178_tile_1	METex20.chr7.116435941.116436178_tile_1	1	Human	hg19	chr7	116435818	116435982	-	TTAGCATTACTTCATATCTGTTCCAAAAAGAAAGACATGCTGTAAGAGACCCTTTGAAGGCAGGCATTTCTGTAAAAGTAAAGAACGTAAGAGGTACAGAAAGACTACTTACAAGGG
METex20.chr7.116435941.116436178_tile_2	METex20.chr7.116435941.116436178_tile_2	1	Human	hg19	chr7	116435926	116436101	+	TAAAATGCTGGCACCCTAAAGCCGAAATGCGCCCATCCTTTTCTGAACTGGTGTCCCGGATATCAGCGATCTTCTCTACTTTCATTGGGGAGCACTATGTCCATGTGAACGCTACTTATGT
METex20.chr7.116435941.116436178_tile_3	METex20.chr7.116435941.116436178_tile_3	1	Human	hg19	chr7	116436048	116436223	-	TGCTTTGACATAGTACTAGCACTATGATGTCTCCCAGAAGGAGGCTGGTCGTGTGTCCACCTCATCATCAGCGTTATCTTCTGATGACAACAGAGAAGGATACGGAGCGACACATTTTACGTTCA
MSH6ex5.chr2.48030559.48030824_tile_1	MSH6ex5.chr2.48030559.48030824_tile_1	1	Human	hg19	chr2	48030484	48030677	-	AGAAGGGGGGGGTATCTTCCGGCAACAGAATTACTGGGCGACACATAGGACCATCACCCCCTCGACTATAGTTAGCCAGGCACAGTAAAACATCTGTTAAAAGAGAGGGTAAAAGTGAGGCTTCATCGTTTGGGGGTTTTA
MSH6ex5.chr2.48030559.48030824_tile_2	MSH6ex5.chr2.48030559.48030824_tile_2	1	Human	hg19	chr2	48030598	48030777	+	CTGTTGCCGGAAGATACCCCCCCCTTCTTAGAGCTTAAAGGATCACGCCATCCTTGCATTACGAAGACTTTTTTTGGAGATGATTTTATTCCTAATGACATTCTAATAGGCTGTGAGGAAGAGGAGCA
MSH6ex5.chr2.48030559.48030824_tile_3	MSH6ex5.chr2.48030559.48030824_tile_3	1	Human	hg19	chr2	48030724	48030909	-	TGTTATTCCTAATGTCACAAATGACTTTCTGATAACAAAACTTTAAGAATCAGTTACCTGTCTCATAAGCGTAGACTTGCCCCCCATATTTGGTCCAGTAACAAGCACACAATAGGCTTTGCCATTTTCCT
NRASex1.chr1.115258688.115258798_tile_1	NRASex1.chr1.115258688.115258798_tile_1	1	Human	hg19	chr1	115258651	115258831	-	CAACAGGTTCTTGCTGGTGTGAAATGACTGAGTACAAACTGGTGGTGGTTGGAGCAGGTGGTGTTGGGAAAAGCGCACTGACAATCCAGCTAATCCAGAACCACTTTGTAGATGAATATGATCCCACC
NRASex2.chr1.115256401.115256619_tile_2	NRASex2.chr1.115256401.115256619_tile_2	1	Human	hg19	chr1	115256335	115256507	+	CCCATAAAGATTCAGAACACAAAGATCATCCTTTCAGAGAAAATAATGCTCCTAGTACCTGTAGAGGTTAATATCCGCAAATGACTTGCTATTATTGATGGCAAATACACAGAGGAAG
NRASex2.chr1.115256401.115256619_tile_3	NRASex2.chr1.115256401.115256619_tile_3	1	Human	hg19	chr1	115256435	115256604	-	TATAGATGGTGAAACCTGTTTGTTGGACATACTGGATACAGCTGGACAAGAAGAGTACAGTGCCATGAGAGACCAATACATGAGGACAGGCGAAGGCTTCCTCTGTGTATTTG
NRASex2.chr1.115256401.115256619_tile_4	NRASex2.chr1.115256401.115256619_tile_4	1	Human	hg19	chr1	115256539	115256722	+	ACCATCTATAACCACTTGTTTTCTGTAAGAATCCTGGGGGTGTGGAGGGTAAGGGGGCAGGGAGGGAGGGAAGTTCAATTTTTATTAAAAACCACAGGGAATGCAATGCTATTGCCAAGGTTAAATAA
NRASex3.chr1.115252190.115252349_tile_1	NRASex3.chr1.115252190.115252349_tile_1	1	Human	hg19	chr1	115252093	115252263	-	AGTTACGGGATTCCATTCATTGAAACCTCAGCCAAGACCAGACAGGTATGGTACAGCTTTCAGCATTTGTGCAAGAGTTTGCATCAGTTGATTAACTCTGGTAGAGATGTGA
NRASex3.chr1.115252190.115252349_tile_2	NRASex3.chr1.115252190.115252349_tile_2	1	Human	hg19	chr1	115252207	115252400	+	TCTTGGCCAGTTCGTGGGCTTGTTTTGTATCAACTGTCCTTGTTGGCAAATCACACTTGTTTCCCACTAGCACCATAGGTACATCATCCGAGTCTTTTACTCGCTTAATCTGCTCCCTAAAAACGGGAATATATTAT
NRASex4.chr1.115251152.115251275_tile_1	NRASex4.chr1.115251152.115251275_tile_1	1	Human	hg19	chr1	115251027	115251194	-	TGTGGTGATGTAACAAGGTGAGCATATGGTTTCTTGGCATAATTACAAATCTTAGTATATAGTATTGGGCAATTTGGAGGAGTGCTGGTGTTATTGTCTATATGTTTTTTGAGTTT
NRASex4.chr1.115251152.115251275_tile_2	NRASex4.chr1.115251152.115251275_tile_2	1	Human	hg19	chr1	115251141	115251328	+	ACATGGCAATCCCATACAACCCTGAGTCCCATCATCACTGCTGTTGAGTTTTTTCATTCGGTACTGGCGTATTTCTCTTACCAGTGTGTAAAAAGCATCTTCAACACCCTATAAAAGGAAAAAATGAAAAAAAATGA
PDGFRAex11.chr4.55141008.55141140_tile_1	PDGFRAex11.chr4.55141008.55141140_tile_1	1	Human	hg19	chr4	55140883	55141049	-	TTCATACCTCGGTTTCTATAAATGACCAGGACAGGTAACTGGTGAATTACCAAAGTCCCAGTGCACCAGAGCTTCACTGAAGCAGCACAGTGACTGGACACAGTAGAGTCCAA
PDGFRAex11.chr4.55141008.55141140_tile_2	PDGFRAex11.chr4.55141008.55141140_tile_2	1	Human	hg19	chr4	55140995	55141177	+	AATTCGCTGGAGGGTCATTGAATCAATCAGCCCAGATGGACATGAATATATTTATGTGGACCCGATGCAGCTGCCTTATGACTCAAGATGGGAGTTTCCAAGAGATGGACTAGTGCTTGGTAAGTTC
PDGFRAex13.chr4.55144063.55144173_tile_1	PDGFRAex13.chr4.55144063.55144173_tile_1	1	Human	hg19	chr4	55144028	55144218	-	CCAGGTCAGTGAGCCCACCTGACTTGGTGCAGGCTCCCAGCAAGTTTACAATGTTCAAATGTGGCCCCAGGTGAGTCATTATCTTCAGTTCAGACATGAGAGCTTGTTTTTCACTGGATCTGGCCGTGGCTGTTGAA
PDGFRAex17.chr4.55152008.55152130_tile_1	PDGFRAex17.chr4.55152008.55152130_tile_1	1	Human	hg19	chr4	55151889	55152061	-	GAGCAGCCAGATCACGGTGGACACACTGCATGGAAAAGGAAGAAATGACTCAGGATCAAGCCATCTGTAGCTGAATAGCATCACCCCTGCAAGACTGGCTGATCCATGGTGGCACTTGG
PDGFRAex17.chr4.55152008.55152130_tile_2	PDGFRAex17.chr4.55152008.55152130_tile_2	1	Human	hg19	chr4	55152009	55152195	+	CGCAACGTCCTCCTGGCACAAGGAAAAATTGTGAAGATCTGTGACTTTGGCCTGGCCAGAGACATCATGCATGATTCGAACTATGTGTCGAAAGGCAGTGTACGTCCTCACTTCCCTCACTGGTCAGGCTCATCC
PIK3CAex1.chr3.178916648.178916965_tile_1	PIK3CAex1.chr3.178916648.178916965_tile_1	1	Human	hg19	chr3	178916521	178916686	-	ATCAAGTGGATGCCCCACAGTTCACCTGATGATGGTCGTGGAGGCATTGTTCTGATTCTTTGCAAGTTTTACATATAAAACTACTTTAAGGAATTAGATGTATGGTTGTC
PIK3CAex1.chr3.178916648.178916965_tile_2	PIK3CAex1.chr3.178916648.178916965_tile_2	1	Human	hg19	chr3	178916615	178916784	+	CTGTGGGGCATCCACTTGATGCCCCCAAGAATCCTAGTAGAATGTTTACTACCAAATGGAATGATAGTGACTTTAGAATGCCTCCGTGAGGCTACATTAATAACCATAAAGCAT
PIK3CAex1.chr3.178916648.178916965_tile_3	PIK3CAex1.chr3.178916648.178916965_tile_3	1	Human	hg19	chr3	178916723	178916887	-	AATTCTTCCCTTTCTGCTTCTTGAGTAACACTTACGAAAATGTAAGAAGATTCATCTTGAAGAAGTTGATGGAGGGGGTATTTTCTTGCTTCTTTAAATAGTTCAT
PIK3CAex1.chr3.178916648.178916965_tile_4	PIK3CAex1.chr3.178916648.178916965_tile_4	1	Human	hg19	chr3	178916831	178917022	+	TTTTTGATGAAACAAGACGACTTTGTGACCTTCGGCTTTTTCAACCCTTTTTAAAAGTAATTGAACCAGTAGGCAACCGTGAAGAAAAGATCCTCAATCGAGAAATTGGTATGATACAATATCCTATTCTAAAAT
PIK3CAex2.chr3.178917478.178917687_tile_1	PIK3CAex2.chr3.178917478.178917687_tile_1	1	Human	hg19	chr3	178917369	178917534	-	CACACACTGGCATGCCGATAGCAAAACCTTTAATAAAATTACATAAAGAATATAACATTCTATTACATACACAGCATGAACATGTTTTTTTTGCAAACAGGGAACT
PIK3CAex2.chr3.178917478.178917687_tile_2	PIK3CAex2.chr3.178917478.178917687_tile_2	1	Human	hg19	chr3	178917473	178917646	+	TGTGTGAATTTGATATGGTTAAAGATCCAGAAGTACAGGACTTCCGAAGAAATATTCTGAACGTTTGTAAAGAAGCTGTGGATCTTAGGGACCTCAATTCACCTCATAGTAGAGCAAT
PIK3CAex2.chr3.178917478.178917687_tile_3	PIK3CAex2.chr3.178917478.178917687_tile_3	1	Human	hg19	chr3	178917589	178917762	-	GACTGCACTATAGTAATGATTAGAGTAGATTAGTCATTTTCTTACCTTTATCTAATTTATTATATATGTGCTTTGGCAATTCTGGTGAAGATTCTACATTTGGAGGATAGACATACA
PIK3CAex7.chr3.178927974.178928126_tile_1	PIK3CAex7.chr3.178927974.178928126_tile_1	1	Human	hg19	chr3	178927877	178928046	-	AATCAAACAAGTTTATATTTCCCCATGCCAATGGACAGTGTTCCTTAAAAAACAAAGAAAAATATTCACTAGTCTAAATTATAAAACACATTTCAAAACACTTTTCTTCC
PIK3CAex7.chr3.178927974.178928126_tile_2	PIK3CAex7.chr3.178927974.178928126_tile_2	1	Human	hg19	chr3	178927989	178928183	+	TACACAGACACTCTAGTATCTGGAAAAATGGCTTTGAATCTTTGGCCAGTACCTCATGGATTAGAAGATTTGCTGAACCCTATTGGTGTTACTGGATCAAATCCAAATAAAGTAAGGTTTTTATTGTCATAAATTAGATAT
PIK3CAex9.chr3.178935998.178936122_tile_2	PIK3CAex9.chr3.178935998.178936122_tile_2	1	Human	hg19	chr3	178936011	178936201	+	AAAGAACAGCTCAAAGCAATTTCTACACGAGATCCTCTCTCTGAAATCACTGAGCAGGAGAAAGATTTTCTATGGAGTCACAGGTAAGTGCTAAAATGGAGATTCTCTGTTTCTTTTTCTTTATTACAGAAAAAATA
PIK3CAex9_OT.chr22.17052960.17053096_tile_2	PIK3CAex9_OT.chr22.17052960.17053096_tile_2	1	Human	hg19	chr22	17052931	17053120	+	AAAGAACAGCTCAAAGCAATTTCTACACGAGATCCTCTCTCTGAAATCACTGCGCAGGAGAAAGATTTTCTATGGACCACAGGTAAGTGCTAAAATGGAGATTCTCTGTTTCTTTTTCTTTATTACAGAAAAAATA
PIK3CAex20.chr3.178951882.178952152_tile_1	PIK3CAex20.chr3.178951882.178952152_tile_1	1	Human	hg19	chr3	178951769	178951934	-	AGCCTTGTAACACATCTCCTGAAACCTATAAGTAATAAGAACAGTTTGGTCAGTTTGGAGCAAATGATGTTAATACCTTCAGGTCTTTGCTCAAATGTCACAAAATTA
PIK3CAex20.chr3.178951882.178952152_tile_2	PIK3CAex20.chr3.178951882.178952152_tile_2	1	Human	hg19	chr3	178951853	178952017	+	TTTCAGGAGATGTGTTACAAGGCTTATCTAGCTATTCGACAGCATGCCAATCTCTTCATAAATCTTTTCTCAATGATGCTTGGCTCTGGAATGCCAGAACTACAAT
PIK3CAex20.chr3.178951882.178952152_tile_3	PIK3CAex20.chr3.178951882.178952152_tile_3	1	Human	hg19	chr3	178951939	178952112	-	ATGTGCATCATTCATTTGTTTCATGAAATACTCCAAAGCCTCTTGCTCAGTTTTATCTAAGGCTAGGGTCTTTCGAATGTATGCAATGTCATCAAAAGATTGTAGTTCTGGCATTCCA
PIK3CAex20.chr3.178951882.178952152_tile_4	PIK3CAex20.chr3.178951882.178952152_tile_4	1	Human	hg19	chr3	178952057	178952243	+	TCATGGTGGCTGGACAACAAAAATGGATTGGATCTTCCACACAATTAAACAGCATGCATTGAACTGAAAAGATAACTGAGAAAATGAAAGCTCACTCTGGATTCCACACTGCACTGTTAATAACTCTCAGC
PTENex1.chr10.89624227.89624305_tile_1	PTENex1.chr10.89624227.89624305_tile_1	1	Human	hg19	chr10	89624194	89624360	-	AAAGAGGAGCAGCCGCAGAAATGGATACAGGTCAAGTCTAAGTCGAATCCATCCTCTTGATATCTCCTTTTGTTTCTGCTAACGATCTCTTTGATGATGGCTGTCATGTCTGGGAG
PTENex1_OT.chr9.33676536.33676658 _tile_1	PTENex1_OT.chr9.33676536.33676658 _tile_1	1	Human	hg19	chr9	33676510	33676682	+	AGGAAATCCCATAGCAATAATGTTTAGATAAATATAGGTCAAGTCTAAGTCGAATCCATCCTCTTGATATCTCCTTTTGTTTCTGCTAACGATCTCTTTGATGATGGCTGTCCTGTCTGGGAG
PTENex2.chr10.89653782.89653866_tile_1	PTENex2.chr10.89653782.89653866_tile_1	1	Human	hg19	chr10	89653653	89653842	-	AGGAAATCCCATAGCAATAATGTTTGGATAAATATCTGAGTACTTTAGTTAAGGAAAGAAATATCTGAAATATGCAGCAATCAAACTAAAAGAATACTTTTTAAAACATTAGCTAGTTATGAAAAGAAAGTTTTC
PTENex2.chr10.89653782.89653866_tile_2	PTENex2.chr10.89653782.89653866_tile_2	1	Human	hg19	chr10	89653787	89653967	+	TGCAGAAAGACTTGAAGGCGTATACAGGAACAATATTGATGATGTAGTAAGGTAAGAATGCTTTGATTTTCTATTTCAAATATTGATGTTTATATTCATGTTGTGTTTTCATTTAGAAAAGATTT
PTENex3.chr10.89685270.89685314_tile_1	PTENex3.chr10.89685270.89685314_tile_1	1	Human	hg19	chr10	89685239	89685405	-	AACTTTCACTTAATAGTTGTTTTAGAAGATATTTGCAAGCATACAAATAAGAAAACATACTTACAGATTGTATATCTTGTAATGGTTTTTATGCTTTGAATCCAAAAACCTTA
PTENex4.chr10.89690803.89690846_tile_1	PTENex4.chr10.89690803.89690846_tile_1	1	Human	hg19	chr10	89690754	89690946	-	TTATTGTTATGACAGTAAGATACAGTCTATCGGGTTTAAGTTATACAACATAGTACAGTACATTCATACCTACCTCTGCAATTAAATTTGGCGGTGTCATAATGTCTTTCAGCACAACTAAAAGAAAAGTTTAAAA
PTENex5.chr10.89692770.89693008_tile_1	PTENex5.chr10.89692770.89693008_tile_1	1	Human	hg19	chr10	89692643	89692808	-	GGATATTGTGCAACTGTGGTAAAAAGATAACCTCAGAATAAGAAAAAAAAACTCTTGAATTTTTAATTAACAAGTAGGTAACTTTAGAAATGTTGCATACAAACTTAACA
PTENex5.chr10.89692770.89693008_tile_2	PTENex5.chr10.89692770.89693008_tile_2	1	Human	hg19	chr10	89692741	89692906	+	TTGCACAATATCCTTTTGAAGACCATAACCCACCACAGCTAGAACTTATCAAACCCTTTTGTGAAGATCTTGACCAATGGCTAAGTGAAGATGACAATCATGTTGCAGCAA
PTENex5.chr10.89692770.89693008_tile_3	PTENex5.chr10.89692770.89693008_tile_3	1	Human	hg19	chr10	89692855	89693047	-	AAAATAACTTACCTTTTTGTCTCTGGTCCTTACTTCCCCATAGAAATCTAGGGCCTCTTGTGCCTTTAAAAATTTGCCCCGATGTAATAAATATGCACATATCATTACACCAGTTCGTCCCTTTCCAGCTTTACAGTGAAT
PTENex5_OT.chr9.33676091.33676311_tile_3	PTENex5_OT.chr9.33676091.33676311_tile_3	1	Human	hg19	chr9	33676091	33676311	+	AATACACATAGCGCCTCTGACTGGGAATAGTTACTCCCTTTTTGTCTCTGGTCCTTACTTCCCCATAGAAATCTAGGGCCTCTTGTGCCTTTAAAAATTTGCCCCGATGTAATAAATATGCATAAATCATTATACCAGTTCGTCCCTTTCCAGCTTTACAGTGAAT
PTENex6.chr10.89711875.89712016_tile_1	PTENex6.chr10.89711875.89712016_tile_1	1	Human	hg19	chr10	89711762	89711941	-	AATACACATAGCGCCTCTGACTGGGAATAGTTACTCCCTGGTGGACAGAAAAAAAAGAGAAGCCAAATTGAAAAAAAATGTTCCATTATAGTTATTTCACTAAATTGCTATGGTAACTGG
PTENex6.chr10.89711875.89712016_tile_2	PTENex6.chr10.89711875.89712016_tile_2	1	Human	hg19	chr10	89711884	89712057	+	TATTATAGCTACCTGTTAAAGAATCATCTGGATTATAGACCAGTGGCACTGTTGTTTCACAAGATGATGTTTGAAACTATTCCAATGTTCAGTGGCGGAACTTGCAGTAAGTGCTTGAA
PTENex6_OT.chr9.33675905.33676121_tile_2	PTENex6_OT.chr9.33675905.33676121_tile_2	1	Human	hg19	chr9	33675875	33676148	-	TACTATAGCTACCTGGTAAAGAATCATCTGGATTATAGACCAGTGGCACTGTTGTTTCACAAGATGATGTTTGAAACTATTCCAATGTTCAGTGGCGGAACTTGCAATCCTCAGTTTGTGGTCTGCCAGCTAAAGGTGAAGATGTATTCCTCCAATTCAGGACCCACACGATGGGAGGACAAGTTCATGTATTTTGAGTTCCCTCAGCCGTTACCTG
PTENex7.chr10.89717610.89717776_tile_1	PTENex7.chr10.89717610.89717776_tile_1	1	Human	hg19	chr10	89717483	89717647	-	AAACTGAGGATCTGCATGGTTAAATACATACCAGTATTATTTCACAGGAAATGCCTTTAACTGTCAAACTGTCAAAAACGATTTTAATGATTAATATCAGCAATATACA
PTENex7.chr10.89717610.89717776_tile_2	PTENex7.chr10.89717610.89717776_tile_2	1	Human	hg19	chr10	89717583	89717750	+	CTCAGTTTGTGGTCTGCCAGCTAAAGGTGAAGATATATTCCTCCAATTCAGGACCCACACGACGGGAAGACAAGTTCATGTACTTTGAGTTCCCTCAGCCGTTACCTG
PTENex7.chr10.89717610.89717776_tile_3	PTENex7.chr10.89717610.89717776_tile_3	1	Human	hg19	chr10	89717697	89717891	-	TAGTTCCTTACATGTCATAAAATAAAATATAGCTTTTAATCTGTCCTTATTTTGGATATTTCTCCCAATGAAAGTAAAGTACAAACCTTTTTTAGCATCTTGTTCTGTTTGTGGAAGAACTCTACTTTGATATCACCACACAC
PTENex9.chr10.89725044.89725229_tile_2	PTENex9.chr10.89725044.89725229_tile_2	1	Human	hg19	chr10	89725011	89725178	+	TAGGTGAAGCTGTACTTCACAAAAACAGTAGAGGAGCCGTCAAATCCAGAGGCTAGCAGTTCAACTTCTGTAACACCAGATGTTAGTGACAATGAACCTGATCATTATAGAT
SMAD4ex8.chr18.48591793.48591976_tile_1	SMAD4ex8.chr18.48591793.48591976_tile_1	1	Human	hg19	chr18	48591668	48591834	-	CAATACTCAGGAGCTATAGGAAATAAATGGGAAAGAACATCCTCCCATGAGAAAGATATAAGGCTTTCACTTGCACTCCACAACACAGTTTTTCCTAAAAGAAAGGGTAAAGG
SMAD4ex8.chr18.48591793.48591976_tile_2	SMAD4ex8.chr18.48591793.48591976_tile_2	1	Human	hg19	chr18	48591764	48591928	+	TCCTGAGTATTGGTGTTCCATTGCTTACTTTGAAATGGATGTTCAGGTAGGAGAGACATTTAAGGTTCCTTCAAGCTGCCCTATTGTTACTGTTGATGGATACGTGGA
SMAD4ex8.chr18.48591793.48591976_tile_3	SMAD4ex8.chr18.48591793.48591976_tile_3	1	Human	hg19	chr18	48591872	48592061	-	AAGACAATGTACTATGCTCAATTTTTTAAAGTAACTATCTGACTATACAATCAATACCTTGCTCTCTCAATGGCTTCTGTCCTGTGGACATTGGAGAGTTGACCCAAACAAAAGCGATCTCCTCCAGAAGGGT
SMAD4ex11.chr18.48604626.48604837_tile_2	SMAD4ex11.chr18.48604626.48604837_tile_2	1	Human	hg19	chr18	48604585	48604750	+	CTTTTCTGTTAGGTCTGTCAGCTGCTGCTGGAATTGGTGTTGATGACCTTCGTCGCTTATGCATACTCAGGATGAGTTTTGTGAAAGGCTGGGGACCGGATTACCCAAGACAG
SMAD4ex11.chr18.48604626.48604837_tile_3	SMAD4ex11.chr18.48604626.48604837_tile_3	1	Human	hg19	chr18	48604699	48604885	-	GGGCCCCAACGGTAAAAGACCTCAGTCTAAAGGTTGTGGGTCTGCAATCGGCATGGTATGAAGTACTTCGTCTAGGAGCTGGAGGGCCCGGTGTAAGTGAATTTCAATCCAGCAAGGTGTTTCTTTGATGCTC
SRCex10.chr20.36031654.36031785_tile_1	SRCex10.chr20.36031654.36031785_tile_1	1	Human	hg19	chr20	36031559	36031751	-	CAGGAAGGCCTGCAGGTACTCGAAGGTGGGCCGCTCCTCAGGCTCCTTCCGCCAGCACTGGCACATGAGGTCGTGCAGGGACTCGGGACACTCCGGCGGGCAGGGCATCCGGTAGCCCCGCTCCACCTGGTCCAGCACCTCGCGG
SRCex10.chr20.36031654.36031785_tile_2	SRCex10.chr20.36031654.36031785_tile_2	1	Human	hg19	chr20	36031705	36031898	+	GGAGGACTACTTCACGTCCACCGAGCCCCAGTACCAGCCCGGGGAGAACCTCTAGGCACAGGCGGGCCCAGACCGGCTTCTCGGCTTGGATCCTGGGCTGGGTGGCCCCTGTCTCGGGGCTTGCCCCACTCTGCCTGCCTG
STK11ex1.chr19.1206913.1207202_tile_1	STK11ex1.chr19.1206913.1207202_tile_1	1	Human	hg19	chr19	1206810	1206977	-	AACATGCCCAGCTGCTGCGGGTCCACCACCTCCATGCTGGACCCAGGGTCCTGGAGTCCCGCCGCCAGCCCTGAGTCCGCGGGTGAGCGGTCCTTCCTTGTGTTCCGA
STK11ex1.chr19.1206913.1207202_tile_2	STK11ex1.chr19.1206913.1207202_tile_2	1	Human	hg19	chr19	1206896	1207064	+	GGTGGTGGACCCGCAGCAGCTGGGCATGTTCACGGAGGGCGAGCTGATGTCGGTGGGTATGGACACGTTCATCCACCGCATCGACTCCACCGAGGTCATCTACCAGCCGCGCCGCAAGCG
STK11ex1.chr19.1206913.1207202_tile_3	STK11ex1.chr19.1206913.1207202_tile_3	1	Human	hg19	chr19	1207010	1207176	-	GATCTTGACGGCCCTCCTGCACAGCGTCTCCGAGTCCAGCACCTCCTTCACCTTGCCGTAAGAGCCTTCCCCCAGCAGGTCCCCCATCAGGTACTTGCCGATGAGCTTGGCCCGC
STK11ex4.chr19.1220372.1220504_tile_1	STK11ex4.chr19.1220372.1220504_tile_1	1	Human	hg19	chr19	1220249	1220423	-	CCAGGCCGTCAATCAGCTGACAGAAGTACCTGCGGGCAGCACACACCCGTCCTGGGGCCGAGGCCTCCCTGCCCCTCACAGGGGTCCCCTTTGCAGCTGCCTGGGAGCCTCCCAAACACCACAGGCCC
STK11ex6.chr19.1221212.1221339_tile_2	STK11ex6.chr19.1221212.1221339_tile_2	1	Human	hg19	chr19	1221195	1221368	+	CACCACGGGTCTGTACCCCTTCGAAGGGGACAACATCTACAAGTTGTTTGAGAACATCGGGAAGGGGAGCTACGCCATCCCGGGCGACTGTGGCCCCCCGCTCTCTGACCTGCTGAAAGGTGGGAG
STK11ex8.chr19.1222984.1223171_tile_1	STK11ex8.chr19.1222984.1223171_tile_1	1	Human	hg19	chr19	1222915	1223091	-	CATGCTGCGCCACCGGTCCTTGGTGTCTGGGCTCGGTGGGATGGGCACTGGTGCTTCAGCCGGAGGATGTTTCTTCCGGAACCAGCTGCAAACGCCCAGAAGCAGTGGCGCCTGTCAGGCTGGCACCAGGGC
STK11ex8.chr19.1222984.1223171_tile_2	STK11ex8.chr19.1222984.1223171_tile_2	1	Human	hg19	chr19	1223041	1223222	+	GACTGTGGTGCCGTACTTGGAGGACCTGCACGGCGCGGACGAGGACGAGGACCTCTTCGACATCGAGGATGACATCATCTACACTCAGGACTTCACGGTGCCCGGTGAGTCTGGCGGGGGCCCCTGCCCGGCT
TP53ex2ex3ex4.chr17.7579241.7580010_tile_3	TP53ex2ex3ex4.chr17.7579241.7580010_tile_3	1	Human	hg19	chr17	7579229	7579399	-	CAGCTACGGTTTCCGTCTGGGCTTCTTGCATTCTGGGACAGCCAAGTCTGTGACTTGCACGGTCAGTTGCCCTGAGGGGCTGGCTTCCATGAGACTTCAATGCCTGGCCGTATCCC
TP53ex2ex3ex4.chr17.7579241.7580010_tile_4	TP53ex2ex3ex4.chr17.7579241.7580010_tile_4	1	Human	hg19	chr17	7579327	7579496	+	GCCCAGACGGAAACCGTAGCTGCCCTGGTAGGTTTTCTGGGAAGGGACAGAAGATGACAGGGGCCAGGAGGGGGCTGGTGCAGGGGCCGCCGGTGTAGGAGCTGCTGGTGCAGGGGCCACGGGG
TP53ex2ex3ex4.chr17.7579241.7580010_tile_5	TP53ex2ex3ex4.chr17.7579241.7580010_tile_5	1	Human	hg19	chr17	7579443	7579612	-	CCTTGCCGTCCCAAGCAATGGATGATTTGATGCTGTCCCCGGACGATATTGAACAATGGTTCACTGAAGACCCAGGTCCAGATGAAGCTCCCAGAATGCCAGAGGCTGCTCCCCCCGTGGCC
TP53ex2ex3ex4.chr17.7579241.7580010_tile_7	TP53ex2ex3ex4.chr17.7579241.7580010_tile_7	1	Human	hg19	chr17	7579669	7579839	-	CCCACCACCCCCACCCCAACCCCAGCCCCCTAGCAGAGACCTGTGGGAAGCGAAAATTCCATGGGACTGACTTTCTGCTCTTGTCTTTCAGACTTCCTGAAAACAACGTTCTGG
TP53ex2ex3ex4.chr17.7579241.7580010_tile_8	TP53ex2ex3ex4.chr17.7579241.7580010_tile_8	1	Human	hg19	chr17	7579765	7579935	+	GCTGGGGTTGGGGTGGGGGTGGTGGGCCTGCCCTTCCAATGGATCCACTCACAGTTTCCATAGGTCTGAAAATGTTTCCTGACTCAGAGGGGGCTCGACGCTAGGATCTGACTGCGGCTCCTCC
TP53ex2ex3ex4.chr17.7579241.7580010_tile_9	TP53ex2ex3ex4.chr17.7579241.7580010_tile_9	1	Human	hg19	chr17	7579879	7580062	-	TGGCATGGTGTTGGGGGAGGGGGTTCCTTCTCTGCAGGCCCAGGTGACCCAGGGTTGGAAGTGTCTCATGCTGGATCCCCACTTTTCCTCTTGCAGCAGCCAGACTGCCTTCCGGGTCACTGCCATGGAGGAGCCG
TP53ex5TP53ex6.chr17.7578157.7578574_tile_2	TP53ex5TP53ex6.chr17.7578157.7578574_tile_2	1	Human	hg19	chr17	7578118	7578295	+	CCCCTCCTCCCAGAGACCCCAGTTGCAAACCAGACCTCAGGCGGCTCATAGGGCACCACCACACTATGTCGAAAAGTGTTTCTGTCATCCAAATACTCCACACGCAAATTTCCTTCCACTCGGATAAG
TP53ex5TP53ex6.chr17.7578157.7578574_tile_3	TP53ex5TP53ex6.chr17.7578157.7578574_tile_3	1	Human	hg19	chr17	7578242	7578434	-	CGCTGCCCCCACCATGAGCGCTGCTCAGATAGCGATGGTGAGCAGCTGGGGCTGGAGAGACGACAGGGCTGGTTGCCCAGGGTCCCCAGGCCTCTGATTCCTCACTGATTGCTCTTAGGTCTGGCCCCTCCTCAGCATCT
TP53ex5TP53ex6.chr17.7578157.7578574_tile_4	TP53ex5TP53ex6.chr17.7578157.7578574_tile_4	1	Human	hg19	chr17	7578354	7578523	+	CTGAGCAGCGCTCATGGTGGGGGCAGCGCCTCACAACCTCCGTCATGTGCTGTGACTGCTTGTAGATGGCCATGGCGCGGACGCGGGTGCCGGGCGGGGGTGTGGAATCAACCCACAG
TP53ex5TP53ex6.chr17.7578157.7578574_tile_5	TP53ex5TP53ex6.chr17.7578157.7578574_tile_5	1	Human	hg19	chr17	7578474	7578651	-	CCGTCTTCCAGTTGCTTTATCTGTTCACTTGTGCCCTGACTTTCAACTCTGTCTCCTTCCTCTTCCTACAGTACTCCCCTGCCCTCAACAAGATGTTTTGCCAACTGGCCAAGACCTGCCCTGTGCAGC
TP53ex7.chr17.7577498.7577608_tile_1	TP53ex7.chr17.7577498.7577608_tile_1	1	Human	hg19	chr17	7577473	7577649	-	CTGTGTTATCTCCTAGGTTGGCTCTGACTGTACCACCATCCACTACAACTACATGTGTAACAGTTCCTGCATGGGCGGCATGAACCGGAGGCCCATCCTCACCATCATCACACTGGAAGACTCCAGG
TP53ex8TP53ex9.chr17.7576833.7577175_tile_2	TP53ex8TP53ex9.chr17.7576833.7577175_tile_2	1	Human	hg19	chr17	7576806	7576970	+	GTCCCAAGACTTAGTACCTGAAGGGTGAAATATTCTCCATCCAGTGGTTTCTTCTTTGGCTGGGGAGAGGAGCTGGTGTTGTTGGGCAGTGCTAGGAAAGAGGCAAGG
TP53ex8TP53ex9.chr17.7576833.7577175_tile_3	TP53ex8TP53ex9.chr17.7576833.7577175_tile_3	1	Human	hg19	chr17	7576918	7577100	-	GAATCTCCGCAAGAAAGGGGAGCCTCACCACGAGCTGCCCCCAGGGAGCACTAAGCGAGGTAAGCAAGCAGGACAAGAAGCGGTGGAGGAGACCAAGGGTGCAGTTATGCCTCAGATTCACTTTTATCACCTTTCC
TP53ex8TP53ex9.chr17.7576833.7577175_tile_4	TP53ex8TP53ex9.chr17.7576833.7577175_tile_4	1	Human	hg19	chr17	7577050	7577219	+	CTCTTCCTCTGTGCGCCGGTCTCTCCCAGGACAGGCACAAACACGCACCTCAAAGCTGTTCCGTCCCAGTAGATTACCACTACTCAGGATAGGAAAAGAGAAGCAAGAGGCAGTAAGGA
TP53ex10.chr17.7573926.7574033_tile_1	TP53ex10.chr17.7573926.7574033_tile_1	1	Human	hg19	chr17	7573869	7574062	-	CAGATCCGTGGGCGTGAGCGCTTCGAGATGTTCCGAGAGCTGAATGAGGCCTTGGAACTCAAGGATGCCCAGGCTGGGAAGGAGCCAGGGGGGAGCAGGGCTCACTCCAGGTGAGTGACCTCAGCCCCTTCCTGGCCCTACTCCC
TP53ex11.chr17.7572907.7573028_tile_1	TP53ex11.chr17.7572907.7573028_tile_1	1	Human	hg19	chr17	7572883	7573055	-	CCTGCTTCTGTCTCCTACAGCCACCTGAAGTCCAAAAAGGGTCAGTCTACCTCCCGCCATAAAAAACTCATGTTCAAGACAGAAGGGCCTGACTCAGACTGACATTCTCCACTTCTTGTTCCCC
[Intervals]									
Species	Build ID	Chromosome	Target Start	Target Stop					
Human	hg19	chr1	115251147	115251280					
Human	hg19	chr1	115252185	115252354					
Human	hg19	chr1	115256416	115256604					
Human	hg19	chr1	115258677	115258786					
Human	hg19	chr2	29443642	29443706					
Human	hg19	chr2	48030554	48030829					
Human	hg19	chr3	41266012	41266161					
Human	hg19	chr3	138665109	138665221					
Human	hg19	chr3	178916609	178916970					
Human	hg19	chr3	178917473	178917692					
Human	hg19	chr3	178927969	178928131					
Human	hg19	chr3	178936039	178936127					
Human	hg19	chr3	178951877	178952157					
Human	hg19	chr4	55141003	55141145					
Human	hg19	chr4	55144058	55144178					
Human	hg19	chr4	55152003	55152135					
Human	hg19	chr4	55592018	55592221					
Human	hg19	chr4	55593577	55593713					
Human	hg19	chr4	55594175	55594292					
Human	hg19	chr4	55599231	55599363					
Human	hg19	chr4	55602662	55602780					
Human	hg19	chr4	153244028	153244303					
Human	hg19	chr4	153245331	153245551					
Human	hg19	chr4	153247153	153247388					
Human	hg19	chr4	153249355	153249546					
Human	hg19	chr4	153250819	153250942					
Human	hg19	chr5	112173743	112173988					
Human	hg19	chr5	112174526	112174778					
Human	hg19	chr5	112174975	112175370					
Human	hg19	chr5	112175469	112176130					
Human	hg19	chr7	55241609	55241741					
Human	hg19	chr7	55242412	55242518					
Human	hg19	chr7	55248981	55249176					
Human	hg19	chr7	55259407	55259572					
Human	hg19	chr7	116339543	116340298					
Human	hg19	chr7	116380901	116381084					
Human	hg19	chr7	116411898	116412048					
Human	hg19	chr7	116417441	116417528					
Human	hg19	chr7	116418825	116419016					
Human	hg19	chr7	116422037	116422156					
Human	hg19	chr7	116423353	116423526					
Human	hg19	chr7	116435936	116436183					
Human	hg19	chr7	140453072	140453195					
Human	hg19	chr7	140481371	140481498					
Human	hg19	chr9	80343425	80343586					
Human	hg19	chr9	80409374	80409513					
Human	hg19	chr9	80412431	80412569					
Human	hg19	chr10	89624222	89624310					
Human	hg19	chr10	89653777	89653871					
Human	hg19	chr10	89685266	89685319					
Human	hg19	chr10	89690798	89690851					
Human	hg19	chr10	89692765	89693013					
Human	hg19	chr10	89711870	89712021					
Human	hg19	chr10	89717605	89717781					
Human	hg19	chr10	89725041	89725152					
Human	hg19	chr10	123279488	123279688					
Human	hg19	chr12	25362724	25362850					
Human	hg19	chr12	25378543	25378712					
Human	hg19	chr12	25380163	25380351					
Human	hg19	chr12	25398203	25398323					
Human	hg19	chr14	105246425	105246558					
Human	hg19	chr15	66727437	66727561					
Human	hg19	chr16	68846033	68846171					
Human	hg19	chr16	68847213	68847403					
Human	hg19	chr16	68855899	68856128					
Human	hg19	chr17	7572922	7573013					
Human	hg19	chr17	7573922	7574036					
Human	hg19	chr17	7576848	7576931					
Human	hg19	chr17	7577014	7577160					
Human	hg19	chr17	7577498	7577613					
Human	hg19	chr17	7578172	7578294					
Human	hg19	chr17	7578366	7578559					
Human	hg19	chr17	7579307	7579586					
Human	hg19	chr17	7579699	7579726					
Human	hg19	chr17	7579834	7579917					
Human	hg19	chr17	37880974	37881169					
Human	hg19	chr18	48591788	48591981					
Human	hg19	chr18	48604621	48604842					
Human	hg19	chr19	1206908	1207149					
Human	hg19	chr19	1220367	1220400					
Human	hg19	chr19	1221221	1221344					
Human	hg19	chr19	1222979	1223176					
Human	hg19	chr20	36031584	36031787					
Human	hg19	chr20	57480433	57480540					
Human	hg19	chr20	57484403	57484483					
