[Probes]									
Target ID	Species	Build ID	Chromosome	Start Position	End Position	Strand	ULSO Sequence	DLSO Sequence	Probe Strand
AKT1ex2.chr14.105246425.105246553_tile_1	Human	hg19	chr14	105246425	105246553	-	TAGAGTGTGCGTGGCTCTCACCAC	GTAAGTATCCCCTTGGCCTCTCG	-
ALKex23.chr2.29443572.29443701_tile_2	Human	hg19	chr2	29443572	29443701	+	CCATGAGCTCCAGCAGGATGAAC	GATACAAAGTTACATTTTCAGCAGCTAC	+
APCex15_1.chr5.112173836.112173974_tile_1	Human	hg19	chr5	112173836	112173974	-	TGTTGCTGGATGGTAGTTGCCTAGAC	GCCAGTATTAAAATTGTCTGACCTATTATC	-
APCex15_1.chr5.112173836.112173974_tile_2	Human	hg19	chr5	112173836	112173974	+	GTTTGGAGAGAGAACGCGGAATT	TCTCAGGAAGACAGAAGTTCTGGGT	+
APCex15_2.chr5.112174625.112174757_tile_1	Human	hg19	chr5	112174625	112174757	-	CACAAAGACTGGCTTACATTTTGATTAATT	ATAAACAGGATAAGTTGTACTTTGATTCC	-
APCex15_2.chr5.112174625.112174757_tile_2	Human	hg19	chr5	112174625	112174757	+	AGAAACAAATCGAGTGGGTTCTAATCATG	GCATAAAATATAATGAAGAGAAACGTCATG	+
APCex15_3.chr5.112174992.112176072_tile_2	Human	hg19	chr5	112174992	112176072	+	ACACCTTCATCTAATGCCAAGAGGCA	AAGATACTCCAATATGTTTTTCAAGATGT	+
APCex15_3.chr5.112174992.112176072_tile_3	Human	hg19	chr5	112174992	112176072	-	CTATTTGCAGGGTATTAGCAGAATCTGC	TGTTTCTTGGTTAATAGAAGAAACTTTGC	-
APCex15_3.chr5.112174992.112176072_tile_4	Human	hg19	chr5	112174992	112176072	+	CTTTGTCATCAGCTGAAGATGAAATAGG	AGCAGTGTCACAGCACCCTAGAACCAAAT	+
APCex15_3.chr5.112174992.112176072_tile_5	Human	hg19	chr5	112174992	112176072	-	TCTGAGCACCACTTTTGGAGGGA	TCACAGGATCTTCAGCTGACCTAGTT	-
APCex15_3.chr5.112174992.112176072_tile_7	Human	hg19	chr5	112174992	112176072	-	AGGTGTTTTACTTCTGCTTGGTGGCA	GTGAACTGACAGAAGTACATCTGCTAAA	-
APCex15_3.chr5.112174992.112176072_tile_8	Human	hg19	chr5	112174992	112176072	+	CCCAGTGATCTTCCAGATAGCCCT	AAGCAAGCTGCAGTAAATGCTGC	+
APCex15_3.chr5.112174992.112176072_tile_9	Human	hg19	chr5	112174992	112176072	-	TCAGAGCACTCAGGCTGGATGAA	CTCTCTTTTCAGCAGTAGGTGCTTTAT	-
APCex15_3.chr5.112174992.112176072_tile_10	Human	hg19	chr5	112174992	112176072	+	TTTTGCCACGGAAAGTACTCCAGATG	CAGAATCAGAGCAGCCTAAAGAATCAA	+
APCex15_3.chr5.112174992.112176072_tile_11	Human	hg19	chr5	112174992	112176072	-	GGCATGGCAGAAATAATACATTCTTCTAGT	TCCCATTGTCATTTTCCTGAACTGGA	-
APCex15_3.chr5.112174992.112176072_tile_12	Human	hg19	chr5	112174992	112176072	+	AGGACCTATTAGATGATTCAGATGATGATG	GTGTACAAACTTCTACCATCACAAAACAGG	+
BRAFex11.chr7.140481376.140481493_tile_1	Human	hg19	chr7	140481376	140481493	-	GGATCATTTGGAACAGTCTACAAGGGAA	CGCATCAATAAACTATTTTGATTAGTTTCA	-
BRAFex11.chr7.140481376.140481493_tile_2	Human	hg19	chr7	140481376	140481493	+	CACCACATTACATACTTACCATGCCAC	TCAAGCCAAACAGAAAAAGAAAACCTT	+
BRAFex15.chr7.140453075.140453193_tile_1	Human	hg19	chr7	140453075	140453193	-	ACTGTTTTCCTTTACTTACTACACCTC	AGAATTGAGGCTATTTTTCCACTGATTA	-
CDH1ex8.chr16.68846038.68846166_tile_1	Human	hg19	chr16	68846038	68846166	-	TTGAAGGTCAGCAGCTTGAACCAC	TTCATGCCAGCCTGCCTGTCTTCT	-
CDH1ex8.chr16.68846038.68846166_tile_2	Human	hg19	chr16	68846038	68846166	+	TGCAGAGTTTCCCTACGTATACCCT	AACTCCTTAGAGGGTTTCCAAAGAAAGG	+
CDH1ex9.chr16.68847216.68847398_tile_2	Human	hg19	chr16	68847216	68847398	+	ACTTTGTAAATGACACATCTCTTTGCTCTG	TGATGATGGTGGACAATTTGTCGTCAC	+
CDH1ex9.chr16.68847216.68847398_tile_3	Human	hg19	chr16	68847216	68847398	-	GCGAATCTACTTCTAAGAAGATACCAG	TCAATATGGTGTATACAGCCTCCCACG	-
CDH1ex12.chr16.68855904.68856128_tile_2	Human	hg19	chr16	68855904	68856128	+	AAGCTGCCACATTTTCTGTGTATTTTC	ATCCAAAGCCTCAGGTCATAAACATCA	+
CDH1ex12.chr16.68855904.68856128_tile_3	Human	hg19	chr16	68855904	68856128	-	GTTGCCAAAATAAAACTCAGGTACCCAC	CCTCTCACAGAAGAATATAGTTCGAGG	-
CTNNB1ex2.chr3.41266017.41266151_tile_1	Human	hg19	chr3	41266017	41266151	-	TTTTCTGTCTGGTTCCATGGCCATGTCCA	GAAATAAAGTCAAATCTGAAAGACAGCCA	-
CTNNB1ex2.chr3.41266017.41266151_tile_2	Human	hg19	chr3	41266017	41266151	+	GTTTCGTATTTATAGCTGATTTGATGGAG	GGAAGAGGATGTGGATACCTCCCAA	+
EGFRex18.chr7.55241613.55241736_tile_1	Human	hg19	chr7	55241613	55241736	-	CACTTTGATCTTTTTGAATTCAGTTTCCTT	AAAGCAGTGCCAGACATGGCCCAG	-
EGFRex18.chr7.55241613.55241736_tile_2	Human	hg19	chr7	55241613	55241736	+	TCCCAACCAAGCTCTCTTGAGGATCTT	AGAGTCCTTGCAAGCTGTATATTTCCA	+
EGFRex19.chr7.55242414.55242513_tile_1	Human	hg19	chr7	55242414	55242513	-	ATGAGAAAAGGTGGGCCTGAGGTTCA	TGACAGAGAGAGAAGGAAGACGTTAAC	-
EGFRex20.chr7.55248985.55249171_tile_1	Human	hg19	chr7	55248985	55249171	+	CTGGAAGGGGTCCATGTGCCCCTCCTT	CTCATGCCCTTCGGCTGCCTCCTGGACTAT	+
EGFRex20.chr7.55248985.55249171_tile_2	Human	hg19	chr7	55248985	55249171	-	AGACCGCATGTGAGGATCCTGGCT	TGCGTGATGAGCTGCACGGTGGA	-
EGFRex21.chr7.55259411.55259567_tile_1	Human	hg19	chr7	55259411	55259567	-	GCCCAAAATCTGTGATCTTGACATGCT	GTCATGTTCATGCCAGGCTCTGA	-
EGFRex21.chr7.55259411.55259567_tile_2	Human	hg19	chr7	55259411	55259567	+	GGAACGTACTGGTGAAAACACCG	CTTCCCACTAGCTGTATTGTTTAACAC	+
ERBB2ex20.chr17.37880979.37881164_tile_2	Human	hg19	chr17	37880979	37881164	+	ACCCTCTCAGCGTACCCTTGTC	ACCATGTCCGGGAAAACCGCGGA	+
ERBB2ex20.chr17.37880979.37881164_tile_3	Human	hg19	chr17	37880979	37881164	-	AAGAGTCCCCATCCTAGCCCCTTG	TAAGAGGCAGCCATAGGGCATAAGCTG	-
FBXW7ex7.chr4.153250824.153250937_tile_1	Human	hg19	chr4	153250824	153250937	-	GACAACACTTTAAAAGTTTGGTCAGCAG	CTTAGTTATTTGGATAGCAAATATCAGAGC	-
FBXW7ex7.chr4.153250824.153250937_tile_2	Human	hg19	chr4	153250824	153250937	+	AGGAAGAGTAAACTTACTTTGCCTGTG	AGAAAGATGTGCAGATTAGAAATATGTTAA	+
FBXW7ex8.chr4.153249360.153249541_tile_1	Human	hg19	chr4	153249360	153249541	-	CCTTATATGGGCATACTTCCACTGTGC	TGACAGTGTGCTCTTAAATTAGATTTAATT	-
FBXW7ex8.chr4.153249360.153249541_tile_2	Human	hg19	chr4	153249360	153249541	+	CCCAACCATGACAAGATTTTCCCTTAC	CTCTCATTTGTGATGACCATACTCCACC	+
FBXW7ex8.chr4.153249360.153249541_tile_3	Human	hg19	chr4	153249360	153249541	-	AGTAACTTTACTCCAAATTTTAATGAGCT	CAACATCATCATTAGTGGATCTACAGATC	-
FBXW7ex9.chr4.153247158.153247383_tile_1	Human	hg19	chr4	153247158	153247383	-	TCCAGAGACTGAAACCTGTCTACACAC	CAAATTGCTGATCCAGTACAGTCCAAAA	-
FBXW7ex9.chr4.153247158.153247383_tile_2	Human	hg19	chr4	153247158	153247383	+	CCTGTAATGAATAGACTCTATTAGTATGCC	CCATCAAAACATGTAAACACTGGCCTG	+
FBXW7ex9.chr4.153247158.153247383_tile_3	Human	hg19	chr4	153247158	153247383	-	CCTTGACTAAATCTACCATGTTTTCTCAT	TCATGTTGCAGCAGTCCGCTGTG	-
FBXW7ex10.chr4.153245336.153245546_tile_2	Human	hg19	chr4	153245336	153245546	+	AATGATCTCATTTTTAATGAACAAAACGAA	TCCACTTGTTAACGACTGGTGCCCTGTTA	+
FBXW7ex10.chr4.153245336.153245546_tile_3	Human	hg19	chr4	153245336	153245546	-	TTGATAGGAAGAGTATCCATACTTCTATTC	TGGAACTCAAAGACAATATTCTTGTCT	-
FBXW7ex11.chr4.153244033.153244301_tile_1	Human	hg19	chr4	153244033	153244301	-	AAACCAAGCTGCTGGTGCTGGACTTTG	TTGTTCTCAGTGGTGCAGGATGT	-
FBXW7ex11.chr4.153244033.153244301_tile_2	Human	hg19	chr4	153244033	153244301	+	TTTTCTGCTCTTCACTTCATGTCCAC	TAAATTCACCCGTTTTCAAGTCCCATAG	+
FBXW7ex11.chr4.153244033.153244301_tile_3	Human	hg19	chr4	153244033	153244301	-	CCAGTAATTAAATTCTTTTGGTTTTTGTCT	TCGAAACCTAGTCACATTGGAGAGT	-
FGFR2ex6.chr10.123279493.123279683_tile_1	Human	hg19	chr10	123279493	123279683	-	TTTACAGTGATGCCCAGCCCCACATCCA	CTTTGATTTCCTGTTGGAGTTGAGAGA	-
FGFR2ex6.chr10.123279493.123279683_tile_2	Human	hg19	chr10	123279493	123279683	+	CGTTCTTTTCCACGTGCTTGATCCA	GGGAAGAAAGGAGGAGTGGGGAT	+
FOXL2ex1.chr3.138665113.138665213_tile_1	Human	hg19	chr3	138665113	138665213	-	TCAGCCTCAACGAGTGCTTCATCAAGG	TTCCGGCCGCCGCCCGCGCACTTCCAG	-
GNAQex4.chr9.80412436.80412564_tile_1	Human	hg19	chr9	80412436	80412564	-	AGGGATCATCGAATACCCCTTTGACT	TCAAAACAAGATAGGCTTTATACCAATTAT	-
GNAQex4.chr9.80412436.80412564_tile_2	Human	hg19	chr9	80412436	80412564	+	AGTTACTACCTGAAAATGACACTTTGT	TGAGAATGTCAGTGACACCATCACAC	+
GNAQex5.chr9.80409379.80409508_tile_2	Human	hg19	chr9	80409379	80409508	+	ATCAGATAATAAAATGATAATCCATTGCCT	CTCTGACCTTTGGCCCCCTACAT	+
GNAQex5.chr9.80409379.80409508_tile_3	Human	hg19	chr9	80409379	80409508	-	GACTTGGATGATCATCGTCATTCAAGAG	GAAGAAAATGGATACACTGCTTTGAAAAT	-
GNAQex6.chr9.80343430.80343583_tile_2	Human	hg19	chr9	80343430	80343583	+	CTACTGAGCTGTGGTATGAGTGCTGA	GCCTTGCTTTCCTCCATTCGGTTCT	+
GNAQex6.chr9.80343430.80343583_tile_3	Human	hg19	chr9	80343430	80343583	-	GACAAATCCAACACAGGGCTACAAAAAC	CTCTTTAGAACAATTATCACATACCCCTG	-
GNASex6.chr20.57480438.57480535_tile_1	Human	hg19	chr20	57480438	57480535	-	CTGTTTTATGTGCTGATGGGTTGGGT	AAGTTTAGAGAAAGGCAAGAGCTTGAA	-
GNASex8.chr20.57484405.57484478_tile_1	Human	hg19	chr20	57484405	57484478	-	ACAGCTGGTTATTCCAGAGGGACTGGG	GAAACAAAATTGAGGTCAATGGATCTCAC	-
KITex9.chr4.55592023.55592216_tile_1	Human	hg19	chr4	55592023	55592216	-	TTTAGTGTCTGCACATCCACTGGCAGTAC	TCATAATCAACAGAAAATGTCCTTTTACAA	-
KITex9.chr4.55592023.55592216_tile_2	Human	hg19	chr4	55592023	55592216	+	AGGGCTTTTGTTTTCTTCCCTTTAGATG	GTAAGGCTTACAACGATGTGGGCAA	+
KITex9.chr4.55592023.55592216_tile_3	Human	hg19	chr4	55592023	55592216	-	GAATGAACTTAAAATCATGACTGATATGGT	TTCAACCGTGCCATTGTGCTTGAATGC	-
KITex11.chr4.55593581.55593708_tile_1	Human	hg19	chr4	55593581	55593708	-	CCATTTATCTCCTCAACAACCTTCCAC	GTAAATATTTGTAGGTCAGAATCATCACA	-
KITex11.chr4.55593581.55593708_tile_2	Human	hg19	chr4	55593581	55593708	+	CCCCACAGAAACCCATGTATGAAGTAC	CATGTCACCTTTTTGGGTACACATAAC	+
KITex13.chr4.55594176.55594287_tile_1	Human	hg19	chr4	55594176	55594287	-	CTGACAGACAATAAAAGGCAGCTTGGA	AAATTGGAAACATGCATTTTAGCAAAA	-
KITex17.chr4.55599235.55599358_tile_1	Human	hg19	chr4	55599235	55599358	+	ATGAATTTAAATGGTTTTCTTTTCTCCTCC	AATTATGTGGTTAAAGGAAACGTGAGTACC	+
KITex17.chr4.55599235.55599358_tile_2	Human	hg19	chr4	55599235	55599358	-	ATACTTAATTTGACTGCTAAAATGTGTGA	GAATCATTCTTGATGTCTCTGGCTAGA	-
KITex18.chr4.55602664.55602775_tile_1	Human	hg19	chr4	55602664	55602775	-	GTCTAATGAAGTTGTCTTTGGCAAGGA	GTAATAGAAGCACAACAGAGTCAATAATG	-
KRASex1.chr12.25398208.25398329_tile_1	Human	hg19	chr12	25398208	25398329	-	TAGGCAAGAGTGCCTTGACGATAC	GACCATTTTCATGAGTACTTATTACAAGA	-
KRASex1.chr12.25398208.25398329_tile_2	Human	hg19	chr12	25398208	25398329	+	ATTCGTCCACAAAATGATTCTGAATTAGC	TAATACACTATCAAATACTCCACCAGTACC	+
KRASex2.chr12.25380168.25380346_tile_1	Human	hg19	chr12	25380168	25380346	-	TGCAATGAGGGACCAGTACATGAGG	TCTTTGCTAATGCCATGCATATAATATTTA	-
KRASex2.chr12.25380168.25380346_tile_2	Human	hg19	chr12	25380168	25380346	+	TATTATTTATGGCAAATACACAAAGAAAGC	AGAAACACAGTCTGGATTATTACAGTGC	+
KRASex3.chr12.25378548.25378707_tile_1	Human	hg19	chr12	25378548	25378707	-	ACAGGCTCAGGACTTAGCAAGAAGTT	CAGTTTTTCTCTCAATTATGCTATACTAGG	-
KRASex3.chr12.25378548.25378707_tile_2	Human	hg19	chr12	25378548	25378707	+	GCTGATGTTTCAATAAAAGGAATTCCA	GTTATAGCACAGTCATTAGTAACACAAAT	+
KRASex4.chr12.25362729.25362845_tile_1	Human	hg19	chr12	25362729	25362845	-	GATGAGCAAAGATGGTAAAAAGAAGAAA	TTCCTGCTCCATGCAGACTGTTAGCTT	-
KRASex4.chr12.25362729.25362845_tile_2	Human	hg19	chr12	25362729	25362845	+	CATAATTACACACTTTGTCTTTGACTTCT	GCTTCATGTGTACAGGTAACAAATTTC	+
MAP2K1ex2.chr15.66727445.66727495_tile_1	Human	hg19	chr15	66727445	66727495	-	AAGGCAAACTCACCTTTCTGGCCATGA	TCAAGGCGCTTTCGCTGCTGCTCATCA	-
METex1.chr7.116339642.116340262_tile_1	Human	hg19	chr7	116339642	116340262	-	TTTGGCTCCCAGGGCGCTCACCACACAGT	CTGCCACAGCTAATGAGTTGATCATCAT	-
METex1.chr7.116339642.116340262_tile_2	Human	hg19	chr7	116339642	116340262	+	GAGGTTCACTGCATATTCTCCCCACA	ATTCTTCTTATTTCCCAGATCATCCATTGC	+
METex1.chr7.116339642.116340262_tile_3	Human	hg19	chr7	116339642	116340262	-	CTCAGGTAAAACATCAATGTAGGACTGG	GATGAACCGGTCCTTTACAGATGAAAG	-
METex1.chr7.116339642.116340262_tile_4	Human	hg19	chr7	116339642	116340262	+	GAAACGAAAGATGGTTTTATGTTTTTGACG	AACTCTAGATGCTCAGACTTTTCACAC	+
METex1.chr7.116339642.116340262_tile_5	Human	hg19	chr7	116339642	116340262	-	CACTTCCTTCTTTGTGGATCTCTTTTT	CCTTTGGACCGTCAAGAAGTAAATAAAATT	-
METex1.chr7.116339642.116340262_tile_6	Human	hg19	chr7	116339642	116340262	+	TCTGGAGTGTATTCTCACAGAAAAGAG	ACAAAGCAAGCCAGATTCTGCCGAA	+
METex1.chr7.116339642.116340262_tile_7	Human	hg19	chr7	116339642	116340262	-	GCTCATGATTGGGTCCGTAAAAATGC	CGAACACCCCGAAAAGAATGTCATC	-
METex4.chr7.116380906.116381079_tile_1	Human	hg19	chr7	116380906	116381079	-	AAATGTCTGCAGCCCAAGCCAT	GGAATTTTCTAGACTTAGCAACTATGTGT	-
METex4.chr7.116380906.116381079_tile_2	Human	hg19	chr7	116380906	116381079	+	TCTTCACAGATCACGAAGATCCCATTG	CCTGCAATCTACAAGGTAGGAATCTCT	+
METex4.chr7.116380906.116381079_tile_3	Human	hg19	chr7	116380906	116381079	-	GACTCACAGCTAAATGAGTAAATTGATTTT	AGACAGATCTGTTGAGTCCATGTCC	-
METex13.chr7.116411903.116412043_tile_2	Human	hg19	chr7	116411903	116412043	+	TCTTTAACAAGCTCTTTCTTTCTCTCTG	ATGAATCTGTAGACTACCGAGCTACTT	+
METex13.chr7.116411903.116412043_tile_3	Human	hg19	chr7	116411903	116412043	-	CTTGGCAGAGGTAAATACTTCCTTTAGG	TGAAACCATTTCTGTAGTTGGGCTTAC	-
METex15.chr7.116417443.116417523_tile_1	Human	hg19	chr7	116417443	116417523	-	AAGCTATTTATTAGGTTGCAAACCACA	GTGCAAAAGAAAGAACTTGGTTAGCAC	-
METex16.chr7.116418830.116419011_tile_2	Human	hg19	chr7	116418830	116419011	+	TCACTGTTCCATAATGAAGTTAATGTCTCC	CCTGCGAAGTGAAGGGTCTCCG	+
METex16.chr7.116418830.116419011_tile_3	Human	hg19	chr7	116418830	116419011	-	AAAGACTCAGAGCAGGCCTATTT	AGATTCCCAGGAGCGAGAGGACA	-
METex17.chr7.116422042.116422151_tile_1	Human	hg19	chr7	116422042	116422151	-	TCATGCCTTTGGCTACTTGAAGACCA	CTCAAAAATTAGTTTGGTCTTAATGGCTCA	-
METex17.chr7.116422042.116422151_tile_2	Human	hg19	chr7	116422042	116422151	+	ATCCAACTGTAAAAGATCTTATTGGCT	GGAATCTGTTTCCCACTGTTCAATGC	+
METex18.chr7.116423358.116423523_tile_1	Human	hg19	chr7	116423358	116423523	-	CATACATGTCTCTGGCAAGACCAAAATC	CCATAACTTCTGAAGGAAGTATTTCATCT	-
METex18.chr7.116423358.116423523_tile_2	Human	hg19	chr7	116423358	116423523	+	GGATGAAAAATTCACAGTCAAGGTTGC	ATGTATTGGTTATCTCTGAGTTTCTCCTC	+
METex20.chr7.116435941.116436178_tile_1	Human	hg19	chr7	116435941	116436178	-	ATTTCGGCTTTAGGGTGCCAGCATT	GTCTGGGCAGTATTCGGGTTGTA	-
METex20.chr7.116435941.116436178_tile_2	Human	hg19	chr7	116435941	116436178	+	TTCTTTTTGGAACAGATATGAAGTAATGC	GAACGTAAAATGTGTCGCTCCGTATC	+
METex20.chr7.116435941.116436178_tile_3	Human	hg19	chr7	116435941	116436178	-	ACCATTGGACAAAGTGTGGACTGT	CATAAGTAGCGTTCACATGGACATAGT	-
MSH6ex5.chr2.48030559.48030824_tile_1	Human	hg19	chr2	48030559	48030824	-	AGGATGGCGTGATCCTTTAAGCTCTA	TCAGCCTAAGTGTTTTATAGGTCTTCT	-
MSH6ex5.chr2.48030559.48030824_tile_2	Human	hg19	chr2	48030559	48030824	+	ATGGTCCTATGTGTCGCCCAGTAATT	GGAAAATGGCAAAGCCTATTGTGTGC	+
MSH6ex5.chr2.48030559.48030824_tile_3	Human	hg19	chr2	48030559	48030824	-	CTGTGTTTGGAAAATGATCACCTAAGTA	GCTCCTCTTCCTCACAGCCTATTAGAA	-
NRASex1.chr1.115258688.115258798_tile_1	Human	hg19	chr1	115258688	115258798	-	CGCCAATTAACCCTGATTACTGGTTTC	ATAGAGGTGAGGCCCAGTGGTAGCCC	-
NRASex2.chr1.115256401.115256619_tile_2	Human	hg19	chr1	115256401	115256619	+	ATCTTCCCTAGTGTGGTAACCTCATTTC	CCTTCGCCTGTCCTCATGTATTGGTCT	+
NRASex2.chr1.115256401.115256619_tile_3	Human	hg19	chr1	115256401	115256619	-	CCCAGGATTCTTACAGAAAACAAGTGGT	CCATCAATAATAGCAAGTCATTTGCGGAT	-
NRASex2.chr1.115256401.115256619_tile_4	Human	hg19	chr1	115256401	115256619	+	TATCCAGTATGTCCAACAAACAGGTTTC	GCATCTAACTATTCAAGCCCATTTCTGC	+
NRASex3.chr1.115252190.115252349_tile_1	Human	hg19	chr1	115252190	115252349	-	ATACAAAACAAGCCCACGAACTGGCCAAG	TCCATATTCATATTCTTTGTTGTTATGCAT	-
NRASex3.chr1.115252190.115252349_tile_2	Human	hg19	chr1	115252190	115252349	+	AGGTTTCAATGAATGGAATCCCGTAAC	CAGAACATAAGAAAAACAAGATTAGGCTGG	+
NRASex4.chr1.115251152.115251275_tile_1	Human	hg19	chr1	115251152	115251275	-	ACTCAGGGTTGTATGGGATTGCCATG	CTGCCTATCCTCTTCTGCACATTTTC	-
NRASex4.chr1.115251152.115251275_tile_2	Human	hg19	chr1	115251152	115251275	+	CATATGCTCACCTTGTTACATCACCAC	GAGAGCTAGCTCAACGGACACAAT	+
PDGFRAex11.chr4.55141008.55141140_tile_1	Human	hg19	chr4	55141008	55141140	-	GATTGATTCAATGACCCTCCAGCGAAT	CAACGTTCACTCCACATGTAATTGCTG	-
PDGFRAex11.chr4.55141008.55141140_tile_2	Human	hg19	chr4	55141008	55141140	+	TGGTCATTTATAGAAACCGAGGTATGA	CATGGGGTAACCTCCCAAGACTCCCTTTT	+
PDGFRAex13.chr4.55144063.55144173_tile_1	Human	hg19	chr4	55144063	55144173	-	CACATGTGTCCAGTGAAAATCCTCACT	AGAATAAATCACATATCAGTCCAGCTG	-
PDGFRAex17.chr4.55152008.55152130_tile_1	Human	hg19	chr4	55152008	55152130	-	AATTTTTCCTTGTGCCAGGAGGACGTTGC	AGCTGTCTGCCTGGATATAAAGGGC	-
PDGFRAex17.chr4.55152008.55152130_tile_2	Human	hg19	chr4	55152008	55152130	+	GTGTCCACCGTGATCTGGCTGCT	TCCTTCACTTTAATCTCTAAAGTCAGGTG	+
PIK3CAex1.chr3.178916648.178916965_tile_1	Human	hg19	chr3	178916648	178916965	-	GGTAGTAAACATTCTACTAGGATTCTTGGG	CCAAAGCAGAAACCTAAATCAAAGAAGGA	-
PIK3CAex1.chr3.178916648.178916965_tile_2	Human	hg19	chr3	178916648	178916965	+	TGCCTCCACGACCATCATCAGGTGAA	GAACTATTTAAAGAAGCAAGAAAATACCCC	+
PIK3CAex1.chr3.178916648.178916965_tile_3	Human	hg19	chr3	178916648	178916965	-	GGTCACAAAGTCGTCTTGTTTCATCAAAA	GCTTTATGGTTATTAATGTAGCCTCACGGA	-
PIK3CAex1.chr3.178916648.178916965_tile_4	Human	hg19	chr3	178916648	178916965	+	TTACTCAAGAAGCAGAAAGGGAAGAAT	GCAAATAACCATAAAGCTTAACTGTTGTCC	+
PIK3CAex2.chr3.178917478.178917687_tile_1	Human	hg19	chr3	178917478	178917687	-	GTACTTCTGGATCTTTAACCATATCAAATT	CTGTAGATTTGGAAGATCACAATAAAGTAA	-
PIK3CAex2.chr3.178917478.178917687_tile_2	Human	hg19	chr3	178917478	178917687	+	TAAAGGTTTTGCTATCGGCATGCCAG	GTATGTCTATCCTCCAAATGTAGAATCTTC	+
PIK3CAex2.chr3.178917478.178917687_tile_3	Human	hg19	chr3	178917478	178917687	-	GACTATACAAAGATATAGACACAGGTAGAA	TTGCTCTACTATGAGGTGAATTGAGGT	-
PIK3CAex7.chr3.178927974.178928126_tile_1	Human	hg19	chr3	178927974	178928126	-	CCATTTTTCCAGATACTAGAGTGTCTGTGT	CCAAAAGGAAAATTCAACAATCATCTCTAT	-
PIK3CAex7.chr3.178927974.178928126_tile_2	Human	hg19	chr3	178927974	178928126	+	GCATGGGGAAATATAAACTTGTTTGAT	TTTTTATGGCAGTCAAACCTTCTCTCT	+
PIK3CAex9.chr3.178935998.178936122_tile_2	Human	hg19	chr3	178935998	178936122	+	CTAGAGACAATGAATTAAGGGAAAATGAC	ACTGAATTTGGCTGATCTCAGCATG	+
PIK3CAex9_OT.chr22.17052960.17053096_tile_2	Human	hg19	chr22	17052960	17053096	+	CTAGAGACAATGAATTAAGGGAAAATGAC	ACTGAATTTGGCTGATCTCAGCATG	+
PIK3CAex20.chr3.178951882.178952152_tile_1	Human	hg19	chr3	178951882	178952152	-	GATTGGCATGCTGTCGAATAGCTAGATA	GAGAGGCTTTCGTAGACAAAGCTATAAAAA	-
PIK3CAex20.chr3.178951882.178952152_tile_2	Human	hg19	chr3	178951882	178952152	+	ACTGACCAAACTGTTCTTATTACTTATAGG	CTTTTGATGACATTGCATACATTCGAAAG	+
PIK3CAex20.chr3.178951882.178952152_tile_3	Human	hg19	chr3	178951882	178952152	-	TCCATTTTTGTTGTCCAGCCACCATG	GAGCCAAGCATCATTGAGAAAAGATTTATG	-
PIK3CAex20.chr3.178951882.178952152_tile_4	Human	hg19	chr3	178951882	178952152	+	TATTTCATGAAACAAATGAATGATGCACA	AGGCAAAGACCGATTGCATAGGAATTG	+
PTENex1.chr10.89624227.89624305_tile_1	Human	hg19	chr10	89624227	89624305	-	CACGTTCTAAGAGAGTGACAGAAAGGT	CCTGTGGCTGAAGAAAAAGGAGGA	-
PTENex1_OT.chr9.33676536.33676658 _tile_1	Human	hg19	chr9	33676536	33676658	+	CTGTATACGCCTTCAAGTCTTTCTGC	CCTGTGGCTGAAGAAAAAGGAGGA	+
PTENex2.chr10.89653782.89653866_tile_1	Human	hg19	chr10	89653782	89653866	-	CTGTATACGCCTTCAAGTCTTTCTGC	CCCACTATAGCTGGAGTAATAAAAGGTGG	-
PTENex2.chr10.89653782.89653866_tile_2	Human	hg19	chr10	89653782	89653866	+	TATCCAAACATTATTGCTATGGGATTTCC	CTAAGCCACAGAAAAAGATACTTTGTG	+
PTENex3.chr10.89685270.89685314_tile_1	Human	hg19	chr10	89685270	89685314	-	AACTCTACCTCACTCTAACAAGCAGAT	AAACAAAACAAACAAACAAAAAGCCAC	-
PTENex4.chr10.89690803.89690846_tile_1	Human	hg19	chr10	89690803	89690846	-	ATCTCACTCGATAATCTGGATGACTCA	GTGATATAAAGTTATCTTTTGCACTTAGGA	-
PTENex5.chr10.89692770.89693008_tile_1	Human	hg19	chr10	89692770	89693008	-	GCTGTGGTGGGTTATGGTCTTCAAAA	GGTATTTAAAAGAAACACTGGATTCCAGAG	-
PTENex5.chr10.89692770.89693008_tile_2	Human	hg19	chr10	89692770	89693008	+	CTTATTCTGAGGTTATCTTTTTACCACAG	TTCACTGTAAAGCTGGAAAGGGACGA	+
PTENex5.chr10.89692770.89693008_tile_3	Human	hg19	chr10	89692770	89693008	-	CCAGGAAGAGGAAAGGAAAAACATCAA	TGCTGCAACATGATTGTCATCTTCA	-
PTENex5_OT.chr9.33676091.33676311_tile_3	Human	hg19	chr9	33676121	33676287	+	CCACATGATTCTTTACCAGGTAGCTATAGT	TGCTGCAACATGATTGTCATCTTCA	+
PTENex6.chr10.89711875.89712016_tile_1	Human	hg19	chr10	89711875	89712016	-	CCAGATGATTCTTTAACAGGTAGCTATAAT	GTCGTAGCCATTTAAGAACATATATACATT	-
PTENex6.chr10.89711875.89712016_tile_2	Human	hg19	chr10	89711875	89712016	+	ATTCCCAGTCAGAGGCGCTATGTGTAT	ATTCTCATCCTTCCATGTATTGGAACAG	+
PTENex6_OT.chr9.33675905.33676121_tile_2	Human	hg19	chr9	33675905	33676121	-	ATTCCCAGTCAGAGGCGCTATGTGTAT	TGTGTGGTGATATCAAAGTAGAGTTCTTCC	-
PTENex7.chr10.89717610.89717776_tile_1	Human	hg19	chr10	89717610	89717776	-	TATCTTCACCTTTAGCTGGCAGACCAC	CGAAATATGGATTCTGTATCTGCAATCTT	-
PTENex7.chr10.89717610.89717776_tile_2	Human	hg19	chr10	89717610	89717776	+	AATACTGGTATGTATTTAACCATGCAGATC	TGTGTGGTGATATCAAAGTAGAGTTCTTCC	+
PTENex7.chr10.89717610.89717776_tile_3	Human	hg19	chr10	89717610	89717776	-	CACCTGCAGATCTAATAGAAAACAAATTA	AGGTAACGGCTGAGGGAACTCAA	-
PTENex9.chr10.89725044.89725229_tile_2	Human	hg19	chr10	89725044	89725229	+	TGTGGGTTTTCATTTTAAATTTTCTTTCTC	ATTCTGACACCACTGACTCTGATCCA	+
SMAD4ex8.chr18.48591793.48591976_tile_1	Human	hg19	chr18	48591793	48591976	-	CATCCATTTCAAAGTAAGCAATGGAACAC	GAGGGGAGATGGAAATGTAATGCAC	-
SMAD4ex8.chr18.48591793.48591976_tile_2	Human	hg19	chr18	48591793	48591976	+	GGATGTTCTTTCCCATTTATTTCCTATAGC	CCCTTCTGGAGGAGATCGCTTTTGTTT	+
SMAD4ex8.chr18.48591793.48591976_tile_3	Human	hg19	chr18	48591793	48591976	-	GTACATGGGAAAACATAACCTTGAATAA	CCACGTATCCATCAACAGTAACAATAGGG	-
SMAD4ex11.chr18.48604626.48604837_tile_2	Human	hg19	chr18	48604626	48604837	+	TCACCCTGTCCCTCTGATGTCTTCCAAAT	AGCATCAAAGAAACACCTTGCTGG	+
SMAD4ex11.chr18.48604626.48604837_tile_3	Human	hg19	chr18	48604626	48604837	-	TGTAGTCCACCATCCTGATAAGGTTAA	TGTCTTGGGTAATCCGGTCCCCAGCCT	-
SRCex10.chr20.36031654.36031785_tile_1	Human	hg19	chr20	36031654	36031785	-	TCGGTGGACGTGAAGTAGTCCTC	TTCACCATCCCTGTGGGCAGAGCGA	-
SRCex10.chr20.36031654.36031785_tile_2	Human	hg19	chr20	36031654	36031785	+	TTCGAGTACCTGCAGGCCTTCCT	CTGTTGGTCCTCTCTCTGTGGGGCTGAATT	+
STK11ex1.chr19.1206913.1207202_tile_1	Human	hg19	chr19	1206913	1207202	-	ATACCCACCGACATCAGCTCGCCCTCCGTG	CTTCCCTTCTCCAAAATTTTACAAAGAAAA	-
STK11ex1.chr19.1206913.1207202_tile_2	Human	hg19	chr19	1206913	1207202	+	AGGACCCTGGGTCCAGCATGGA	GGCCAAGCTCATCGGCAAGTACCTGAT	+
STK11ex1.chr19.1206913.1207202_tile_3	Human	hg19	chr19	1206913	1207202	-	GATCCTTCGCAACTTCTTCTTCTTGAG	TTGCGGCGCGGCTGGTAGATGACCT	-
STK11ex4.chr19.1220372.1220504_tile_1	Human	hg19	chr19	1220372	1220504	-	AATGCCCTGGCTATGCAGGTACT	AGCTGGGAAGTCACAGAAGTCCAG	-
STK11ex6.chr19.1221212.1221339_tile_2	Human	hg19	chr19	1221212	1221339	+	CTCCCCTCGAAATGAAGCTACAACAT	CCTCATCCCTCTGCCCGCAGCC	+
STK11ex8.chr19.1222984.1223171_tile_1	Human	hg19	chr19	1222984	1223171	-	TCCTCCAAGTACGGCACCACAGT	GGTCCAGTTTTCCGACCCAGCT	-
STK11ex8.chr19.1222984.1223171_tile_2	Human	hg19	chr19	1222984	1223171	+	AGACACCAAGGACCGGTGGCGCAGCAT	CTGCTGACTCGGCCAGGATGTC	+
TP53ex2ex3ex4.chr17.7579241.7580010_tile_3	Human	hg19	chr17	7579241	7580010	-	TGTCCCTTCCCAGAAAACCTACCAGGG	CCTGCATTTCTTTTGTTTGGAACTTTGG	-
TP53ex2ex3ex4.chr17.7579241.7580010_tile_4	Human	hg19	chr17	7579241	7580010	+	CTTGGCTGTCCCAGAATGCAAGAA	GGAGCAGCCTCTGGCATTCTGG	+
TP53ex2ex3ex4.chr17.7579241.7580010_tile_5	Human	hg19	chr17	7579241	7580010	-	TGCTCTTTTCACCCATCTACAGTCCC	CCTGCACCAGCAGCTCCTACAC	-
TP53ex2ex3ex4.chr17.7579241.7580010_tile_7	Human	hg19	chr17	7579241	7580010	-	TGTGAGTGGATCCATTGGAAGGGCAGG	TAAGGACAAGGGTTGGGCTGGGGACCTGGA	-
TP53ex2ex3ex4.chr17.7579241.7580010_tile_8	Human	hg19	chr17	7579241	7580010	+	TCCCACAGGTCTCTGCTAGGGG	ATGGCAGTGACCCGGAAGGCAGTCT	+
TP53ex2ex3ex4.chr17.7579241.7580010_tile_9	Human	hg19	chr17	7579241	7580010	-	ACAGGAAGCCGAGCTGTCTCAGACAC	CAGTCAGATCCTAGCGTCGAGC	-
TP53ex5TP53ex6.chr17.7578157.7578574_tile_2	Human	hg19	chr17	7578157	7578574	+	AGGGCCACTGACAACCACCCTTAA	ATGCTGAGGAGGGGCCAGACCTAAGA	+
TP53ex5TP53ex6.chr17.7578157.7578574_tile_3	Human	hg19	chr17	7578157	7578574	-	TCACAGCACATGACGGAGGTTGTGAGG	TATCCGAGTGGAAGGAAATTTGCGTG	-
TP53ex5TP53ex6.chr17.7578157.7578574_tile_4	Human	hg19	chr17	7578157	7578574	+	CAGCCCCAGCTGCTCACCATCGCTAT	CTGCACAGGGCAGGTCTTGGCCAGTT	+
TP53ex5TP53ex6.chr17.7578157.7578574_tile_5	Human	hg19	chr17	7578157	7578574	-	GCTTACGCATGTTTGTTTCTTTGCTG	TGTGGGTTGATTCCACACCCCCG	-
TP53ex7.chr17.7577498.7577608_tile_1	Human	hg19	chr17	7577498	7577608	-	AAGGCGCACTGGCCTCATCTTGGGC	TCAGGAGCCACTTGCCACCCTGCAC	-
TP53ex8TP53ex9.chr17.7576833.7577175_tile_2	Human	hg19	chr17	7576833	7577175	+	TTAGACTGGAAACTTTCCACTTGATAAGAG	AAAGGTGATAAAAGTGAATCTGAGGCA	+
TP53ex8TP53ex9.chr17.7576833.7577175_tile_3	Human	hg19	chr17	7576833	7577175	-	AGAGACCGGCGCACAGAGGAAGA	TTGCCTCTTTCCTAGCACTGCCCA	-
TP53ex8TP53ex9.chr17.7576833.7577175_tile_4	Human	hg19	chr17	7576833	7577175	+	GTGAGGCTCCCCTTTCTTGCGGAGATT	AATCAGGTCCTACCTGTCCCATTT	+
TP53ex10.chr17.7573926.7574033_tile_1	Human	hg19	chr17	7573926	7574033	-	TTACTTCTCCCCCTCCTCTGTTGCTG	CTGCCTTCCTAGGTTGGAAAGCC	-
TP53ex11.chr17.7572907.7573028_tile_1	Human	hg19	chr17	7572907	7573028	-	CTCACTCATGTGATGTCATCTCTCCTC	ACTGACAGCCTCCCACCCCCAT	-
[Targets]									
TargetA	TargetB	Target Number	Species	Build ID	Chromosome	Start Position	End Position	Probe Strand	Sequence
AKT1ex2.chr14.105246425.105246553_tile_1	AKT1ex2.chr14.105246425.105246553_tile_1	1	Human	hg19	chr14	105246402	105246591	+	GCGCCACAGAGAAGTTGTTGAGGGGAGCCTCACGTTGGTCCACATCCTGCGGCCGCTCCTTGTAGCCAATGAAGGTGCCATCATTCTTGAGGAGGAAGTAGCGTGGCCGCCAGGTCTTGATGTACTCCCCTACAGACGTGCGG
ALKex23.chr2.29443572.29443701_tile_2	ALKex23.chr2.29443572.29443701_tile_2	1	Human	hg19	chr2	29443619	29443802	-	CTGTTCCTCCCAGTTTAAGATTTGCCCAGACTCAGCTCAGTTAATTTTGGTTACATCCCTCTCTGCTCTGCAGCAAATTCAACCACCAGAACATTGTTCGCTGCATTGGGGTGAGCCTGCAATCCCTGCCCCG
APCex15_1.chr5.112173836.112173974_tile_1	APCex15_1.chr5.112173836.112173974_tile_1	1	Human	hg19	chr5	112173713	112173892	+	AACATGACTGTCCTTTCACCATATTTGAATACTACAGTGTTACCCAGCTCCTCTTCATCAAGAGGAAGCTTAGATAGTTCTCGTTCTGAAAAAGATAGAAGTTTGGAGAGAGAACGCGGAATTG
APCex15_1.chr5.112173836.112173974_tile_2	APCex15_1.chr5.112173836.112173974_tile_2	1	Human	hg19	chr5	112173843	112174013	-	GGTATGAATGGCTGACACTTCTTCCATGACTTTGGCAATCTGGGCTGCAGTGGTGGAGATCTGCAAACCTCGCTTTGAAGAAGTTCCTGGATTTTCTGTTGCTGGATGGTAGTTGCCTAGACC
APCex15_2.chr5.112174625.112174757_tile_1	APCex15_2.chr5.112174625.112174757_tile_1	1	Human	hg19	chr5	112174497	112174680	+	ACTGAGAGCACTGATGATAAACACCTCAAGTTCCAACCACATTTTGGACAGCAGGAATGTGTTTCTCCATACAGGTCACGGGGAGCCAATGGTTCAGAAACAAATCGAGTGGGTTCTAATCATGG
APCex15_2.chr5.112174625.112174757_tile_2	APCex15_2.chr5.112174625.112174757_tile_2	1	Human	hg19	chr5	112174621	112174808	-	TATAATTTGTTGGTCTCTCTTCTTCTTCATGCTGTTCTTCTTCAGAGTAACGTTCACTATAATTGGTAGGCTTATCATCTTCATAGTCATCTTCTTGACACAAAGACTGGCTTACATTTTGATTAATTC
APCex15_3.chr5.112174992.112176072_tile_2	APCex15_3.chr5.112174992.112176072_tile_2	1	Human	hg19	chr5	112174949	112175113	-	CTACACAATAAGTCTGTATTGTTTCTTGGTTAATAGAAGAAACTTTGCAAGTGGCAGCCTTTTGAGGCTGACCACTTCTACTCTGTGCAGAACTTGGATGGAGCTGATTC
APCex15_3.chr5.112174992.112176072_tile_3	APCex15_3.chr5.112174992.112176072_tile_3	1	Human	hg19	chr5	112175037	112175204	+	ATACAGACTTATTGTGTAGAAGATACTCCAATATGTTTTTCAAGATGTAGTTCATTATCATCTTTGTCATCAGCTGAAGATGAAATAGGATGTAATCAGACGACACAGGAA
APCex15_3.chr5.112174992.112176072_tile_4	APCex15_3.chr5.112174992.112176072_tile_4	1	Human	hg19	chr5	112175127	112175291	-	GGAACTTCGCTCACAGGATCTTCAGCTGACCTAGTTCCAATCTTTTCTTTTATTTCTGCTATTTGCAGGGTATTAGCAGAATCTGCTTCCTGTGTCGTCTGATTACAT
APCex15_3.chr5.112174992.112176072_tile_5	APCex15_3.chr5.112174992.112176072_tile_5	1	Human	hg19	chr5	112175227	112175393	+	GCGAAGTTCCAGCAGTGTCACAGCACCCTAGAACCAAATCCAGCAGACTGCAGGGTTCTAGTTTATCTTCAGAATCAGCCAGGCACAAAGCTGTTGAATTTTCTTCAGGAGCGAAATC
APCex15_3.chr5.112174992.112176072_tile_7	APCex15_3.chr5.112174992.112176072_tile_7	1	Human	hg19	chr5	112175441	112175608	+	TTGATAGTTTTGAGAGTCGTTCGATTGCCAGCTCCGTTCAGAGTGAACCATGCAGTGGAATGGTAAGTGGCATTATAAGCCCCAGTGATCTTCCAGATAGCCCTGGACAAACCA
APCex15_3.chr5.112174992.112176072_tile_8	APCex15_3.chr5.112174992.112176072_tile_8	1	Human	hg19	chr5	112175549	112175715	-	AGGTCCACTCTCTCTCTTTTCAGCAGTAGGTGCTTTATTTTTAGGTACTTCTCGCTTGGTTTGAGCTGTTTGAGGAGGTGGTGGAGGTGTTTTACTTCTGCTTGGTGGCATGGTTTGTCC
APCex15_3.chr5.112174992.112176072_tile_9	APCex15_3.chr5.112174992.112176072_tile_9	1	Human	hg19	chr5	112175655	112175819	+	AGAGTGGACCTAAGCAAGCTGCAGTAAATGCTGCAGTTCAGAGGGTCCAGGTTCTTCCAGATGCTGATACTTTATTACATTTTGCCACGGAAAGTACTCCAGATGGATTTTCTTG
APCex15_3.chr5.112174992.112176072_tile_10	APCex15_3.chr5.112174992.112176072_tile_10	1	Human	hg19	chr5	112175761	112175927	-	TTTCATTCCCATTGTCATTTTCCTGAACTGGAGGCATTATTCTTAATTCCACATCTTTCTGTATAAATGGCTCATCGAGGCTCAGAGCACTCAGGCTGGATGAACAAGAAAATC
APCex15_3.chr5.112174992.112176072_tile_11	APCex15_3.chr5.112174992.112176072_tile_11	1	Human	hg19	chr5	112175869	112176042	+	ATGAAACAGAATCAGAGCAGCCTAAAGAATCAAATGAAAACCAAGAGAAAGAGGCAGAAAAAACTATTGATTCTGAAAAGGACCTATTAGATGATTCAGATGATGATGATATTGAAAT
APCex15_3.chr5.112174992.112176072_tile_12	APCex15_3.chr5.112174992.112176072_tile_12	1	Human	hg19	chr5	112175973	112176160	-	AGGCAGCTGACTTGGTTTCCTTGCCACAGGTGGAGGTAATTTTGAAGCAGTCTGGGCTGGCTTTTTTGCTTTACGTGATGACTTTGTTGGCATGGCAGAAATAATACATTCTTCTAGTATTTCAATAT
BRAFex11.chr7.140481376.140481493_tile_1	BRAFex11.chr7.140481376.140481493_tile_1	1	Human	hg19	chr7	140481247	140481412	+	AACAGTGAATATTTCCTTTGATGATATTTTTTACAAAATAAAAGTTGTTAAACATATCCTATTATGACTTGTCACAATGTCACCACATTACATACTTACCATGCCACT
BRAFex11.chr7.140481376.140481493_tile_2	BRAFex11.chr7.140481376.140481493_tile_2	1	Human	hg19	chr7	140481357	140481547	-	CTTGACTTTTTTACTGTTTTTATCAAGAAAACACTTGGTAGACGGGACTCGAGTGATGATTGGGAGATTCCTGATGGGCAGATTACAGTGGGACAAAGAATTGGATCTGGATCATTTGGAACAGTCTACAAGGGAAA
BRAFex15.chr7.140453075.140453193_tile_1	BRAFex15.chr7.140453075.140453193_tile_1	1	Human	hg19	chr7	140453044	140453222	+	TACCATCCACAAAATGGATCCAGACAACTGTTCAAACTGATGGGACCCACTCCATCGAGATTTCACTGTAGCTAGACCAAAATCACCTATTTTTACTGTGAGGTCTTCATGAAGAAATATATCT
CDH1ex8.chr16.68846038.68846166_tile_1	CDH1ex8.chr16.68846038.68846166_tile_1	1	Human	hg19	chr16	68845915	68846082	+	GCACATGGTTAAATATTCTGGTTCCATGTGTTGGGCTGGGCTAGGCCAAAGGTGGCTAGTGTTCCTGGTCCTGACTTGGTTGTGTCGATCTCTCTGCAGAGTTTCCCTACGTATACCCTG
CDH1ex8.chr16.68846038.68846166_tile_2	CDH1ex8.chr16.68846038.68846166_tile_2	1	Human	hg19	chr16	68846033	68846204	-	ATAGAATTACCGTGGTGGGATTGAAGATCGGAGGATTATCGTTGGTGTCAGTGACTGTGATCACAGCTGTTGCTGTTGTGCTTAACCCCTCACCTTGAAGGTCAGCAGCTTGAACCACC
CDH1ex9.chr16.68847216.68847398_tile_2	CDH1ex9.chr16.68847216.68847398_tile_2	1	Human	hg19	chr16	68847183	68847355	-	TTCAATATGGTGTATACAGCCTCCCACGCTGGGGTATTGGGGGCATCAGCATCAGTCACTTTCAGTGTGGTGATTACGACGTTAGCCTCGTTCTCAGGCACCTGACCCTTGTACTG
CDH1ex9.chr16.68847216.68847398_tile_3	CDH1ex9.chr16.68847216.68847398_tile_3	1	Human	hg19	chr16	68847301	68847489	+	ATGATGATGGTGGACAATTTGTCGTCACCACAAATCCAGTGAACAACGATGGCATTTTGAAAACAGCAAAGGTTTGTATGGTACCTGGCAAGATGCAGAAACTGGCATCCTCACAGCTGTTCATACCCTTGTCCC
CDH1ex12.chr16.68855904.68856128_tile_2	CDH1ex12.chr16.68855904.68856128_tile_2	1	Human	hg19	chr16	68855871	68856035	-	TCCTCTCACAGAAGAATATAGTTCGAGGTTCTGGTATGGGGGCGTTGTCATTCACATCAGACAGGATCAGCAGAAGTGTCCCTGTTCCAGTAGCAACTGGAGAACCTAAGA
CDH1ex12.chr16.68855904.68856128_tile_3	CDH1ex12.chr16.68855904.68856128_tile_3	1	Human	hg19	chr16	68855981	68856156	+	AATCCAAAGCCTCAGGTCATAAACATCATTGATGCAGACCTTCCTCCCAATACATCTCCCTTCACAGCAGAACTAACACACGGGGCGAGTGCCAACTGGACCATTCAGTACAACGACCCAA
CTNNB1ex2.chr3.41266017.41266151_tile_1	CTNNB1ex2.chr3.41266017.41266151_tile_1	1	Human	hg19	chr3	41265892	41266060	+	TAAAAATATTTCAATGGGTCATATCACAGATTCTTTTTTTTTAAATTAAAGTAACATTTCCAATCTACTAATGCTAATACTGTTTCGTATTTATAGCTGATTTGATGGAGT
CTNNB1ex2.chr3.41266017.41266151_tile_2	CTNNB1ex2.chr3.41266017.41266151_tile_2	1	Human	hg19	chr3	41266002	41266186	-	TCAGGATTGCCTTTACCACTCAGAGAAGGAGCTGTGGTAGTGGCACCAGAATGGATTCCAGAGTCCAGGTAAGACTGTTGCTGCCAGTGACTAACAGCCGCTTTTCTGTCTGGTTCCATGGCCATGTCCAA
EGFRex18.chr7.55241613.55241736_tile_1	EGFRex18.chr7.55241613.55241736_tile_1	1	Human	hg19	chr7	55241536	55241703	+	CCAGCATGGTGAGGGCTGAGGTGACCCTTGTCTCTGTGTTCTTGTCCCCCCCAGCTTGTGGAGCCTCTTACACCCAGTGGAGAAGCTCCCAACCAAGCTCTCTTGAGGATCTTG
EGFRex18.chr7.55241613.55241736_tile_2	EGFRex18.chr7.55241613.55241736_tile_2	1	Human	hg19	chr7	55241646	55241828	-	GGGCTCCCCACCAGACCATGAGAGGCCCTGCGGCCCAGCCCAGAGGCCTGTGCCAGGGACCTTACCTTATACACCGTGCCGAACGCACCGGAGCCCAGCACTTTGATCTTTTTGAATTCAGTTTCCTTC
EGFRex19.chr7.55242414.55242513_tile_1	EGFRex19.chr7.55242414.55242513_tile_1	1	Human	hg19	chr7	55242385	55242576	+	TAGGGACTCTGGATCCCAGAAGGTGAGAAAGTTAAAATTCCCGTCGCTATCAAGGAATTAAGAGAAGCAACATCTCCGAAAGCCAACAAGGAAATCCTCGATGTGAGTTTCTGCTTTGCTGTGTGGGGGTCCATGGCTC
EGFRex20.chr7.55248985.55249171_tile_1	EGFRex20.chr7.55248985.55249171_tile_1	1	Human	hg19	chr7	55248912	55249105	-	CTGCGTGATGAGCTGCACGGTGGAGGTGAGGCAGATGCCCAGCAGGCGGCACACGTGGGGGTTGTCCACGCTGGCCATCACGTAGGCTTCCTGGAGGGAGGGAGAGGCACGTCAGTGTGGCTTCGCATGGTGGCCAG
EGFRex20.chr7.55248985.55249171_tile_2	EGFRex20.chr7.55248985.55249171_tile_2	1	Human	hg19	chr7	55249052	55249233	+	GCTCATGCCCTTCGGCTGCCTCCTGGACTATGTCCGGGAACACAAAGACAATATTGGCTCCCAGTACCTGCTCAACTGGTGTGTGCAGATCGCAAAGGTAATCAGGGAAGGGAGATACGGGGAGGGGAGATAAGG
EGFRex21.chr7.55259411.55259567_tile_1	EGFRex21.chr7.55259411.55259567_tile_1	1	Human	hg19	chr7	55259320	55259514	+	CCTGAATTCGGATGCAGAGCTTCTTCCCATGATGATCTGTCCCTCACAGCAGGGTCTTCTCTGTTTCAGGGCATGAACTACTTGGAGGACCGTCGCTTGGTGCACCGCGACCTGGCAGCCAGGAACGTACTGGTGAAAACACCGC
EGFRex21.chr7.55259411.55259567_tile_2	EGFRex21.chr7.55259411.55259567_tile_2	1	Human	hg19	chr7	55259464	55259650	-	GCAGCCTGGTCCCTGGTGTCAGGAAAATGCTGGCTGACCTAAAGCCACCTCCTTACTTTGCCTCCTTCTGCATGGTATTCTTTCTCTTCCGCACCCAGCAGTTTGGCCAGCCCAAAATCTGTGATCTTGACATGCTG
ERBB2ex20.chr17.37880979.37881164_tile_2	ERBB2ex20.chr17.37880979.37881164_tile_2	1	Human	hg19	chr17	37880952	37881116	-	CTAAGAGGCAGCCATAGGGCATAAGCTGTGTCACCAGCTGCACCGTGGATGTCAGGCAGATGCCCAGAAGGCGGGAGACATATGGGGAGCCCACACCAGCCATCACGTATGCTTCCTGGG
ERBB2ex20.chr17.37880979.37881164_tile_3	ERBB2ex20.chr17.37880979.37881164_tile_3	1	Human	hg19	chr17	37881066	37881239	+	GACCATGTCCGGGAAAACCGCGGACGCCTGGGCTCCCAGGACCTGCTGAACTGGTGTATGCAGATTGCCAAGGTATGCACCTGGGCTCTTTGCAGGTCTCTCCGGAGCAAACCCCTATGTCCA
FBXW7ex7.chr4.153250824.153250937_tile_1	FBXW7ex7.chr4.153250824.153250937_tile_1	1	Human	hg19	chr4	153250697	153250862	+	AATCAAAAATGAATTATTGTTTTCTTTTTTCCAGTTGCTACTTGCAATGATATACACAAAATTATGACTTTGTGAAGTGTAGGAAGAGTAAACTTACTTTGCCTGTGA
FBXW7ex7.chr4.153250824.153250937_tile_2	FBXW7ex7.chr4.153250824.153250937_tile_2	1	Human	hg19	chr4	153250807	153250972	-	TATAGGTGCTGAAAGGACATGATGATCATGTGATCACATGCTTACAGTTTTGTGGTAACCGAATAGTTAGTGGTTCTGATGACAACACTTTAAAAGTTTGGTCAGCAGT
FBXW7ex8.chr4.153249360.153249541_tile_1	FBXW7ex8.chr4.153249360.153249541_tile_1	1	Human	hg19	chr4	153249245	153249411	+	CTATTTCAGTAACTCTACACAGAAAGGGCCCAAATTCACCAATAATAGAGGAAGAAGTCCCAACCATGACAAGATTTTCCCTTACCTTTTTTCATGAAGATGCATACAAC
FBXW7ex8.chr4.153249360.153249541_tile_2	FBXW7ex8.chr4.153249360.153249541_tile_2	1	Human	hg19	chr4	153249333	153249514	-	ACAACATCATCATTAGTGGATCTACAGATCGGACACTCAAAGTGTGGAATGCAGAGACTGGAGAATGTATACACACCTTATATGGGCATACTTCCACTGTGCGTTGTATGCATCTTCATGAAAAAAG
FBXW7ex8.chr4.153249360.153249541_tile_3	FBXW7ex8.chr4.153249360.153249541_tile_3	1	Human	hg19	chr4	153249457	153249635	+	TCTCTCATTTGTGATGACCATACTCCACCTGTATGTCCCACTAATGTTCTCAGACACTGGAAAAACACTTAAGATGATTACTTTTGGGTAGAAAGGAAAAGTGATTTAAATAAAATTTAAT
FBXW7ex9.chr4.153247158.153247383_tile_1	FBXW7ex9.chr4.153247158.153247383_tile_1	1	Human	hg19	chr4	153247057	153247221	+	ACAGTGATTATCTGAGTAAAACAACCTTATGATTCATCAGGAGAGCATTTAAGGGAGAGATAAGAGATCTTACCTGTAATGAATAGACTCTATTAGTATGCCCCTGCAAC
FBXW7ex9.chr4.153247158.153247383_tile_2	FBXW7ex9.chr4.153247158.153247383_tile_2	1	Human	hg19	chr4	153247157	153247333	-	GTCATGTTGCAGCAGTCCGCTGTGTTCAATATGATGGCAGGAGGGTTGTTAGTGGAGCATATGATTTTATGGTAAAGGTGTGGGATCCAGAGACTGAAACCTGTCTACACACGTTGCAGG
FBXW7ex9.chr4.153247158.153247383_tile_3	FBXW7ex9.chr4.153247158.153247383_tile_3	1	Human	hg19	chr4	153247283	153247477	+	CCCATCAAAACATGTAAACACTGGCCTGTCTCAATATCCCAAACCCTAAGAGTGGCATCTCGAGAACCGCTAACAACTCTGCAGAGGGAGAAACAGAAAAACAAAACAAAACAAAAAAACCCACGTTTAGAATTTTTAATAAT
FBXW7ex10.chr4.153245336.153245546_tile_2	FBXW7ex10.chr4.153245336.153245546_tile_2	1	Human	hg19	chr4	153245289	153245461	-	ATGGAACTCAAAGACAATATTCTTGTCTCTGGGAATGCAGATTCTACAGTTAAAATCTGGGATATCAAAACAGGACAGTGTTTACAAACATTGCAAGGTAAGTCTTACTCACCT
FBXW7ex10.chr4.153245336.153245546_tile_3	FBXW7ex10.chr4.153245336.153245546_tile_3	1	Human	hg19	chr4	153245405	153245598	+	TTCCACTTGTTAACGACTGGTGCCCTGTTAACGTGTGAATGCAATTCCCTGTCTCCACATCCCAAACACGGATTGATGTATCAAGAGATCCACTCACCACATGGATACCATCAAACTACAAAAGACACAGTTTATTA
FBXW7ex11.chr4.153244033.153244301_tile_1	FBXW7ex11.chr4.153244033.153244301_tile_1	1	Human	hg19	chr4	153243912	153244076	+	GGGATTTTTTTCTTTTTCTTTTCTTTTTTTCTTTTTGCAGGGGGAAGGGCAGGGAGTATATCGTCTACACAATTGGACAAATTCATCTTTTCTGCTCTTCACTTCATGTCCACAT
FBXW7ex11.chr4.153244033.153244301_tile_2	FBXW7ex11.chr4.153244033.153244301_tile_2	1	Human	hg19	chr4	153244022	153244215	-	TTCGAAACCTAGTCACATTGGAGAGTGGGGGGAGTGGGGGAGTTGTGTGGCGGATCAGAGCCTCAAACACAAAGCTGGTGTGTGCAGTTGGGAGTCGGAATGGGACTGAAGAAACCAAGCTGCTGGTGCTGGACTTTGAT
FBXW7ex11.chr4.153244033.153244301_tile_3	FBXW7ex11.chr4.153244033.153244301_tile_3	1	Human	hg19	chr4	153244162	153244333	+	ATAAATTCACCCGTTTTCAAGTCCCATAGTTTTACAGTTCCATCATCTGAGCTGGTAATTACAAAGTTCTTGTTGAACTGTAAACAGGTCACAGCACTCTGATGCTTGTTGGGACCT
FGFR2ex6.chr10.123279493.123279683_tile_1	FGFR2ex6.chr10.123279493.123279683_tile_1	1	Human	hg19	chr10	123279400	123279593	+	AACCTGTGGCCAAACCCATGAAGGAGACCCCAGTTGTGGGTACCTTTAGATTCAGAAAGTCCTCACCTTGAGAACCTTGAGGTAGGGCAGCCCGTCGGGCCCGTATTTACTGCCGTTCTTTTCCACGTGCTTGATCCAC
FGFR2ex6.chr10.123279493.123279683_tile_2	FGFR2ex6.chr10.123279493.123279683_tile_2	1	Human	hg19	chr10	123279540	123279718	-	TCTCTCCACCAGAGCGATCGCCTCACCGGCCCATCCTCCAAGCCGGACTGCCGGCAAATGCCTCCACAGTGGTCGGAGGAGACGTAGAGTTTGTCTGCAAGGTTTACAGTGATGCCCAGCCCCACATCCAG
FOXL2ex1.chr3.138665113.138665213_tile_1	FOXL2ex1.chr3.138665113.138665213_tile_1	1	Human	hg19	chr3	138665082	138665248	+	GGGCCTCTTCATGCGGCGGCGGCGCCGGTAGTTGCCCTTCTCGAACATGTCTTCGCAGGCCGGGTCCAGCGTCCAGTAGTTGCCCTTGCGCTCGCCGCCGCCCTCGCGCGGCA
GNAQex4.chr9.80412436.80412564_tile_1	GNAQex4.chr9.80412436.80412564_tile_1	1	Human	hg19	chr9	80412315	80412480	+	AGCCTACACATGATTCCAGTATTTATAGAGTTTACCAAATGTACTCAAGGCATAAAAGCTGGGAAATAGGTTTCATGGACTCAGTTACTACCTGAAAATGACACTTTGTA
GNAQex4.chr9.80412436.80412564_tile_2	GNAQex4.chr9.80412436.80412564_tile_2	1	Human	hg19	chr9	80412427	80412610	-	TTGTGTCTTCCCTCCTCTAGCTATCTTAATGACTTGGACCGCGTAGCTGACCCTGCCTACCTGCCTACGCAACAAGATGTGCTTAGAGTTCGAGTCCCCACCACAGGGATCATCGAATACCCCTTTGACTT
GNAQex5.chr9.80409379.80409508_tile_2	GNAQex5.chr9.80409379.80409508_tile_2	1	Human	hg19	chr9	80409332	80409500	-	AGAAGAAAATGGATACACTGCTTTGAAAATGTCACCTCTATCATGTTTCTAGTAGCGCTTAGTGAATATGATCAAGTTCTCGTGGAGTCAGACAATGAGGTAAGTGTTCTTTAGAC
GNAQex5.chr9.80409379.80409508_tile_3	GNAQex5.chr9.80409379.80409508_tile_3	1	Human	hg19	chr9	80409448	80409631	+	TCTCTGACCTTTGGCCCCCTACATCGACCATTCTGCAAGGTTAACAATACTCATATTAATAACATATAAAGTAAAACTAAAAAGTCAACATAAATATAGCACTACTTACAAACTTAGGGAAAATATT
GNAQex6.chr9.80343430.80343583_tile_2	GNAQex6.chr9.80343430.80343583_tile_2	1	Human	hg19	chr9	80343399	80343585	-	TCTCTTTAGAACAATTATCACATACCCCTGGTTCCAGAACTCCTCGGTTATTCTGTTCTTAAACAAGAAAGATCTTCTAGAGGAGAAAATCATGTATTCCCATCTAGTCGACTACTTCCCAGAATATGATGGTAAG
GNAQex6.chr9.80343430.80343583_tile_3	GNAQex6.chr9.80343430.80343583_tile_3	1	Human	hg19	chr9	80343531	80343718	+	AGCCTTGCTTTCCTCCATTCGGTTCTGGAAAAAAAAAAAAAATCAGAAAAAACAAGGAGTGAATTACATGATTACTTAATTTGTGAATTGTGTTTATTTTATAAGTCCAACCCATCTTTTGTATACGACCA
GNASex6.chr20.57480438.57480535_tile_1	GNASex6.chr20.57480438.57480535_tile_1	1	Human	hg19	chr20	57480393	57480574	+	TCTTGTGTTCACTTTCAGGAATTCTATGAGCATGCCAAGGCTCTGTGGGAGGATGAAGGAGTGCGTGCCTGCTACGAACGCTCCAACGAGTACCAGCTGATTGACTGTGCCCAGTAGTAAGTAACCGCC
GNASex8.chr20.57484405.57484478_tile_1	GNASex8.chr20.57484405.57484478_tile_1	1	Human	hg19	chr20	57484374	57484560	+	AGGACCTGCTTCGCTGCCGTGTCCTGACTTCTGGAATCTTTGAGACCAAGTTCCAGGTGGACAAAGTCAACTTCCAGTAAGCCAACTGTTACCTTTTTATATAACAGAGATCATGGTTTCTTGACATTCAC
KITex9.chr4.55592023.55592216_tile_1	KITex9.chr4.55592023.55592216_tile_1	1	Human	hg19	chr4	55591894	55592064	+	ACCTCTAACTTTGTTTTAAAAGTATGCCACATCCCAAGTGTTTTATGTATTTATTTATTTTCCTAGAGTAAGCCAGGGCTTTTGTTTTCTTCCCTTTAGATGCTCTGCTTCT
KITex9.chr4.55592023.55592216_tile_2	KITex9.chr4.55592023.55592216_tile_2	1	Human	hg19	chr4	55591998	55592172	-	ATTCAACCGTGCCATTGTGCTTGAATGCACTAGAATCTATAGAACTCTGAACCACTAGCTTTCCAAACGGTGGCCCAGATGAGTTTAGTGTCTGCACATCCACTGGCAGTACAGAAGCAGAG
KITex9.chr4.55592023.55592216_tile_3	KITex9.chr4.55592023.55592216_tile_3	1	Human	hg19	chr4	55592120	55592293	+	TGTAAGGCTTACAACGATGTGGGCAAGACTTCTGCCTATTTTAACTTTGCATTTAAAGGTAACAACAAAGGTATATTTCTTTTTAATCCAATTTAAGGGGATGTTTAGGCTCTGTCT
KITex11.chr4.55593581.55593708_tile_1	KITex11.chr4.55593581.55593708_tile_1	1	Human	hg19	chr4	55593460	55593628	+	AGGTAACCATTTATTTGTTCTCTCTCCAGAGTGCTCTAATGACTGAGACAATAATTATTAAAAGGTGATCTATTTTTCCCTTTCTCCCCACAGAAACCCATGTATGAAGTACA
KITex11.chr4.55593581.55593708_tile_2	KITex11.chr4.55593581.55593708_tile_2	1	Human	hg19	chr4	55593574	55593758	-	GAAAGCCCCTGTTTCATACTGACCAAAACTCAGCCTGTTTCTGGGAAACTCCCATTTGTGATCATAAGGAAGTTGTGTTGGGTCTATGTAAACATAATTGTTTCCATTTATCTCCTCAACAACCTTCCACT
KITex13.chr4.55594176.55594287_tile_1	KITex13.chr4.55594176.55594287_tile_1	1	Human	hg19	chr4	55594147	55594325	+	TAGCGAGTGCCCATTTGACAGAACGGGAAGCCCTCATGTCTGAACTCAAAGTCCTGAGTTACCTTGGTAATCACATGAATATTGTGAATCTACTTGGAGCCTGCACCATTGGAGGTAAAGCCGTG
KITex17.chr4.55599235.55599358_tile_1	KITex17.chr4.55599235.55599358_tile_1	1	Human	hg19	chr4	55599196	55599367	-	AGAATCATTCTTGATGTCTCTGGCTAGACCAAAATCACAAATCTTTGTGATCCGACCATGAGTAAGGAGGATATTTCTGGCTGCCAAGTCTCTGTGAATACACTATTAGGTT
KITex17.chr4.55599235.55599358_tile_2	KITex17.chr4.55599235.55599358_tile_2	1	Human	hg19	chr4	55599310	55599494	+	TAATTATGTGGTTAAAGGAAACGTGAGTACCCATTCTCTGCTTGACAGTCCTGCAAAGGATTTTTAGTTTCAACTTTCGATAAAAATTGTTTCCTGTGATTTTCATAATGTAAATCCTGTCTAGGGATA
KITex18.chr4.55602664.55602775_tile_1	KITex18.chr4.55602664.55602775_tile_1	1	Human	hg19	chr4	55602633	55602811	+	AGGCTCGACTACCTGTGAAGTGGATGGCACCTGAAAGCATTTTCAACTGTGTATACACGTTTGAAAGTGACGTCTGGTCCTATGGGATTTTTCTTTGGGAGCTGTTCTCTTTAGGTAAAATGA
KRASex1.chr12.25398208.25398329_tile_1	KRASex1.chr12.25398208.25398329_tile_1	1	Human	hg19	chr12	25398111	25398278	+	AGAGAAACCTTTATCTGTATCAAAGAATGGTCCTGCACCAGTAATATGCATATTAAAACAAGATTTACCTCTATTGTTGGATCATATTCGTCCACAAAATGATTCTGAATTAGCT
KRASex1.chr12.25398208.25398329_tile_2	KRASex1.chr12.25398208.25398329_tile_2	1	Human	hg19	chr12	25398225	25398414	-	ACCTTATGTGTGACATGTTCTAATATAGTCACATTTTCATTATTTTTATTATAAGGCCTGCTGAAAATGACTGAATATAAACTTGTGGTAGTTGGAGCTGGTGGCGTAGGCAAGAGTGCCTTGACGATACA
KRASex2.chr12.25380168.25380346_tile_1	KRASex2.chr12.25380168.25380346_tile_1	1	Human	hg19	chr12	25380075	25380263	+	CTCAAAAAATAAAAACTATAATTACTCCTTAATGTCAGCTTATTATATTCAATTTAAACCCACCTATAATGGTGAATATCTTCAAATGATTTAGTATTATTTATGGCAAATACACAAAGAAAGCCCTCCCCAGT
KRASex2.chr12.25380168.25380346_tile_2	KRASex2.chr12.25380168.25380346_tile_2	1	Human	hg19	chr12	25380199	25380384	-	CCCTTCTCAGGATTCCTACAGGAAGCAAGTAGTAATTGATGGAGAAACCTGTCTCTTGGATATTCTCGACACAGCAGGTCAAGAGGAGTACAGTGCAATGAGGGACCAGTACATGAGGACTGGGGAGG
KRASex3.chr12.25378548.25378707_tile_1	KRASex3.chr12.25378548.25378707_tile_1	1	Human	hg19	chr12	25378449	25378614	+	ATATATTAAATGACATAACAGTTATGATTTTGCAGAAAACAGATCTGTATTTATTTCAGTGTTACTTACCTGTCTTGTCTTTGCTGATGTTTCAATAAAAGGAATTCCAT
KRASex3.chr12.25378548.25378707_tile_2	KRASex3.chr12.25378548.25378707_tile_2	1	Human	hg19	chr12	25378561	25378753	-	TTTTTTTTCTTTCCCAGAGAACAAATTAAAAGAGTTAAGGACTCTGAAGATGTACCTATGGTCCTAGTAGGAAATAAATGTGATTTGCCTTCTAGAACAGTAGACACAAAACAGGCTCAGGACTTAGCAAGAAGTTA
KRASex4.chr12.25362729.25362845_tile_1	KRASex4.chr12.25362729.25362845_tile_1	1	Human	hg19	chr12	25362602	25362789	+	AAAAATTAGGTAATGCTAAAACAAATGCTAATAATTTAGTGTAATGTACAAAAATTACCACTTGTACTAGTATGCCTTAAGAAAAAAGTACAAATTGTATTTACATAATTACACACTTTGTCTTTGACTTCTT
KRASex4.chr12.25362729.25362845_tile_2	KRASex4.chr12.25362729.25362845_tile_2	1	Human	hg19	chr12	25362732	25362914	-	CATCGTATATATTCACATTTTAATACTTTTTATGTATTTCAGGGTGTTGATGATGCCTTCTATACATTAGTTCGAGAAATTCGAAAACATAAAGAAAAGATGAGCAAAGATGGTAAAAAGAAGAAAA
MAP2K1ex2.chr15.66727445.66727495_tile_1	MAP2K1ex2.chr15.66727445.66727495_tile_1	1	Human	hg19	chr15	66727410	66727588	+	GGCCTTTCTTACCCAGAAGCAGAAGGTGGGAGAACTGAAGGATGACGACTTTGAGAAGATCAGTGAGCTGGGGGCTGGCAATGGCGGTGTGGTGTTCAAGGTCTCCCACAAGCCTTCTGGCCTGG
METex1.chr7.116339642.116340262_tile_1	METex1.chr7.116339642.116340262_tile_1	1	Human	hg19	chr7	116339515	116339687	+	CGTCAACAGAGGGACCTGCCAGCGACATGTCTTTCCCCACAATCATACTGCTGACATACAGTCGGAGGTTCACTGCATATTCTCCCCACAGATAGAAGAGCCCAGCCAGTGTCCTG
METex1.chr7.116339642.116340262_tile_2	METex1.chr7.116339642.116340262_tile_2	1	Human	hg19	chr7	116339607	116339772	-	TTATGGTATTGCCTACAAAGAAGTTGATGAACCGGTCCTTTACAGATGAAAGGACTTTGGCTCCCAGGGCGCTCACCACACAGTCAGGACACTGGCTGGGCTCTTCTATC
METex1.chr7.116339642.116340262_tile_3	METex1.chr7.116339642.116340262_tile_3	1	Human	hg19	chr7	116339691	116339858	+	AACTTCTTTGTAGGCAATACCATAAATTCTTCTTATTTCCCAGATCATCCATTGCATTCGATATCAGTGAGAAGGCTAAAGGAAACGAAAGATGGTTTTATGTTTTTGACGGA
METex1.chr7.116339642.116340262_tile_4	METex1.chr7.116339642.116340262_tile_4	1	Human	hg19	chr7	116339799	116339965	-	TCCCTTTGGACCGTCAAGAAGTAAATAAAATTGTTGCTTTCAAAGGCATGGACATACTTAATGGGGTAAGAATCTCTGAACTCAGGTAAAACATCAATGTAGGACTGGTC
METex1.chr7.116339642.116340262_tile_5	METex1.chr7.116339642.116340262_tile_5	1	Human	hg19	chr7	116339907	116340077	+	GAAACTCTAGATGCTCAGACTTTTCACACAAGAATAATCAGGTTCTGTTCCATAAACTCTGGATTGCATTCCTACATGGAAATGCCTCTGGAGTGTATTCTCACAGAAAAGAGA
METex1.chr7.116339642.116340262_tile_6	METex1.chr7.116339642.116340262_tile_6	1	Human	hg19	chr7	116340023	116340203	-	GCGAACACCCCGAAAAGAATGTCATCATTCAGGCTGGCTCCTATTTGTCTAGCAAGCTGGGCCCCAGGCTTGCTGACATACGCAGCCTGAAGTATATTAAACACTTCCTTCTTTGTGGATCTCTTTTTT
METex1.chr7.116339642.116340262_tile_7	METex1.chr7.116339642.116340262_tile_7	1	Human	hg19	chr7	116340153	116340324	+	CACAAAGCAAGCCAGATTCTGCCGAACCAATGGATCGATCTGCCATGTGTGCATTCCCTATCAAATATGTCAACGACTTCTTCAACAAGATCGTCAACAAAAACAATGTGAGATGTCTCCA
METex4.chr7.116380906.116381079_tile_1	METex4.chr7.116380906.116381079_tile_1	1	Human	hg19	chr7	116380777	116380946	+	ATCAAATGATATTTACATGTACCTTTTGTGTACTTACTTTATAATTAATTAACAAACTAGATACCCCTCTGGAAGCTCTTTCCACCCCTTCTCTTCACAGATCACGAAGATCCCATTGA
METex4.chr7.116380906.116381079_tile_2	METex4.chr7.116380906.116381079_tile_2	1	Human	hg19	chr7	116380897	116381091	-	CAGACAGATCTGTTGAGTCCATGTCCCGCTCAGGCATTCCTCCGATCGCACACATTTGTCGTGGCACCAGCCACACTGAACAAAGGGTGGGGCAGAGAGGCATTGACTGCAGGACTGGAAATGTCTGCAGCCCAAGCCATT
METex4.chr7.116380906.116381079_tile_3	METex4.chr7.116380906.116381079_tile_3	1	Human	hg19	chr7	116381039	116381228	+	GCCTGCAATCTACAAGGTAGGAATCTCTAACAGCTGGCATACATGTTTTTGTTTGGTGTTTTTTTTTTTTTTTTGGTTTGGTTTGGTTTGTTTTTTGTTTTTTTAGATACAAATCCCACTAATGAAAAAAATTTA
METex13.chr7.116411903.116412043_tile_2	METex13.chr7.116411903.116412043_tile_2	1	Human	hg19	chr7	116411868	116412034	-	TTGAAACCATTTCTGTAGTTGGGCTTACACTTCGGGCACTTACAAGCCTATCCAAATGAGGAGTGTGTACTCTTGCATCGTAGCGAACTAATTCACTGCCCAGATCTTAAAA
METex13.chr7.116411903.116412043_tile_3	METex13.chr7.116411903.116412043_tile_3	1	Human	hg19	chr7	116411980	116412173	+	AATGAATCTGTAGACTACCGAGCTACTTTTCCAGAAGGTATATTTCAGTTTATTGTTCTGAGAAATACCTATACATATACCTCAGTGGGTTGTGACATTGTTGTTTATTTTTGGTTTTGCATTTATATTTTTATAAAAA
METex15.chr7.116417443.116417523_tile_1	METex15.chr7.116417443.116417523_tile_1	1	Human	hg19	chr7	116417414	116417586	+	AGGGCATTTTGGTTGTGTATATCATGGGACTTTGTTGGACAATGATGGCAAGAAAATTCACTGTGCTGTGAAATCCTTGAACAGTAAGTGGCATTTTATTTAACCATGGAGTATACTTT
METex16.chr7.116418830.116419011_tile_2	METex16.chr7.116418830.116419011_tile_2	1	Human	hg19	chr7	116418783	116418948	-	CAGATTCCCAGGAGCGAGAGGACATTGGGATGACTAAAATCTTTCATGATGATTCCCTCGGTCAGAAATTGGGAAACTTCTCCTATGTCAGTGATTCCTGAGAAATCCAGTGGT
METex16.chr7.116418830.116419011_tile_3	METex16.chr7.116418830.116419011_tile_3	1	Human	hg19	chr7	116418903	116419093	+	GCCTGCGAAGTGAAGGGTCTCCGCTGGTGGTCCTACCATACATGAAACATGGAGATCTTCGAAATTTCATTCGAAATGAGACTCATGTAAGTTGACTGCCAAGCTTACTAACTGGCAAACTAGCTGTAAGCCAGCCATCCCTTCA
METex17.chr7.116422042.116422151_tile_1	METex17.chr7.116422042.116422151_tile_1	1	Human	hg19	chr7	116421913	116422096	+	ACAAGATAATTTTTTATAAATAAATATTTCAGAATTCTAAGGTCAAAATTAGAACAGTAGATGCTTAGTTTATGCTTTTCTAACTCTCTTTGACTGCAGAATCCAACTGTAAAAGATCTTATTGGCTT
METex17.chr7.116422042.116422151_tile_2	METex17.chr7.116422042.116422151_tile_2	1	Human	hg19	chr7	116422043	116422224	-	TCCTTGTCACTTAATTTGGATTGTGGCACAGAGATTCTGATACTTACATACAGTTTCTTGCAGCCAAGTCTCTGTGGACAAACTTTTTGCTTGCAAGATATTTCATGCCTTTGGCTACTTGAAGACCAA
METex18.chr7.116423358.116423523_tile_1	METex18.chr7.116423358.116423523_tile_1	1	Human	hg19	chr7	116423229	116423416	+	ATTTCAAATACTGAAGCCACTTGTTTAATCTGTAGATATTCAGCATCATTGTAAATTATTCTATTTCAGCCACGGGTAATAATTTTTGTCCTTTCTGTAGGCTGGATGAAAAATTCACAGTCAAGGTTGCT
METex18.chr7.116423358.116423523_tile_2	METex18.chr7.116423358.116423523_tile_2	1	Human	hg19	chr7	116423361	116423555	-	TACCACATCTGACTTGGTGGTAAACTTTTGAGTTTGCAGACTTTCCAAAGCCATCCACTTCACTGGCAGCTTTGCACCTGTTTTGTTGTGTACACTATAGTATTCTTTATCATACATGTCTCTGGCAAGACCAAAATCA
METex20.chr7.116435941.116436178_tile_1	METex20.chr7.116435941.116436178_tile_1	1	Human	hg19	chr7	116435818	116435982	+	CCCTTGTAAGTAGTCTTTCTGTACCTCTTACGTTCTTTACTTTTACAGAAATGCCTGCCTTCAAAGGGTCTCTTACAGCATGTCTTTCTTTTTGGAACAGATATGAAGTAATGCTAA
METex20.chr7.116435941.116436178_tile_2	METex20.chr7.116435941.116436178_tile_2	1	Human	hg19	chr7	116435926	116436101	-	ACATAAGTAGCGTTCACATGGACATAGTGCTCCCCAATGAAAGTAGAGAAGATCGCTGATATCCGGGACACCAGTTCAGAAAAGGATGGGCGCATTTCGGCTTTAGGGTGCCAGCATTTTA
METex20.chr7.116435941.116436178_tile_3	METex20.chr7.116435941.116436178_tile_3	1	Human	hg19	chr7	116436048	116436223	+	TGAACGTAAAATGTGTCGCTCCGTATCCTTCTCTGTTGTCATCAGAAGATAACGCTGATGATGAGGTGGACACACGACCAGCCTCCTTCTGGGAGACATCATAGTGCTAGTACTATGTCAAAGCA
MSH6ex5.chr2.48030559.48030824_tile_1	MSH6ex5.chr2.48030559.48030824_tile_1	1	Human	hg19	chr2	48030484	48030677	+	TAAAACCCCCAAACGATGAAGCCTCACTTTTACCCTCTCTTTTAACAGATGTTTTACTGTGCCTGGCTAACTATAGTCGAGGGGGTGATGGTCCTATGTGTCGCCCAGTAATTCTGTTGCCGGAAGATACCCCCCCCTTCT
MSH6ex5.chr2.48030559.48030824_tile_2	MSH6ex5.chr2.48030559.48030824_tile_2	1	Human	hg19	chr2	48030598	48030777	-	TGCTCCTCTTCCTCACAGCCTATTAGAATGTCATTAGGAATAAAATCATCTCCAAAAAAAGTCTTCGTAATGCAAGGATGGCGTGATCCTTTAAGCTCTAAGAAGGGGGGGGTATCTTCCGGCAACAG
MSH6ex5.chr2.48030559.48030824_tile_3	MSH6ex5.chr2.48030559.48030824_tile_3	1	Human	hg19	chr2	48030724	48030909	+	AGGAAAATGGCAAAGCCTATTGTGTGCTTGTTACTGGACCAAATATGGGGGGCAAGTCTACGCTTATGAGACAGGTAACTGATTCTTAAAGTTTTGTTATCAGAAAGTCATTTGTGACATTAGGAATAACA
NRASex1.chr1.115258688.115258798_tile_1	NRASex1.chr1.115258688.115258798_tile_1	1	Human	hg19	chr1	115258651	115258831	+	GGTGGGATCATATTCATCTACAAAGTGGTTCTGGATTAGCTGGATTGTCAGTGCGCTTTTCCCAACACCACCTGCTCCAACCACCACCAGTTTGTACTCAGTCATTTCACACCAGCAAGAACCTGTTG
NRASex2.chr1.115256401.115256619_tile_2	NRASex2.chr1.115256401.115256619_tile_2	1	Human	hg19	chr1	115256335	115256507	-	CTTCCTCTGTGTATTTGCCATCAATAATAGCAAGTCATTTGCGGATATTAACCTCTACAGGTACTAGGAGCATTATTTTCTCTGAAAGGATGATCTTTGTGTTCTGAATCTTTATGGG
NRASex2.chr1.115256401.115256619_tile_3	NRASex2.chr1.115256401.115256619_tile_3	1	Human	hg19	chr1	115256435	115256604	+	CAAATACACAGAGGAAGCCTTCGCCTGTCCTCATGTATTGGTCTCTCATGGCACTGTACTCTTCTTGTCCAGCTGTATCCAGTATGTCCAACAAACAGGTTTCACCATCTATA
NRASex2.chr1.115256401.115256619_tile_4	NRASex2.chr1.115256401.115256619_tile_4	1	Human	hg19	chr1	115256539	115256722	-	TTATTTAACCTTGGCAATAGCATTGCATTCCCTGTGGTTTTTAATAAAAATTGAACTTCCCTCCCTCCCTGCCCCCTTACCCTCCACACCCCCAGGATTCTTACAGAAAACAAGTGGTTATAGATGGT
NRASex3.chr1.115252190.115252349_tile_1	NRASex3.chr1.115252190.115252349_tile_1	1	Human	hg19	chr1	115252093	115252263	+	TCACATCTCTACCAGAGTTAATCAACTGATGCAAACTCTTGCACAAATGCTGAAAGCTGTACCATACCTGTCTGGTCTTGGCTGAGGTTTCAATGAATGGAATCCCGTAACT
NRASex3.chr1.115252190.115252349_tile_2	NRASex3.chr1.115252190.115252349_tile_2	1	Human	hg19	chr1	115252207	115252400	-	ATAATATATTCCCGTTTTTAGGGAGCAGATTAAGCGAGTAAAAGACTCGGATGATGTACCTATGGTGCTAGTGGGAAACAAGTGTGATTTGCCAACAAGGACAGTTGATACAAAACAAGCCCACGAACTGGCCAAGA
NRASex4.chr1.115251152.115251275_tile_1	NRASex4.chr1.115251152.115251275_tile_1	1	Human	hg19	chr1	115251027	115251194	+	AAACTCAAAAAACATATAGACAATAACACCAGCACTCCTCCAAATTGCCCAATACTATATACTAAGATTTGTAATTATGCCAAGAAACCATATGCTCACCTTGTTACATCACCACA
NRASex4.chr1.115251152.115251275_tile_2	NRASex4.chr1.115251152.115251275_tile_2	1	Human	hg19	chr1	115251141	115251328	-	TCATTTTTTTTCATTTTTTCCTTTTATAGGGTGTTGAAGATGCTTTTTACACACTGGTAAGAGAAATACGCCAGTACCGAATGAAAAAACTCAACAGCAGTGATGATGGGACTCAGGGTTGTATGGGATTGCCATGT
PDGFRAex11.chr4.55141008.55141140_tile_1	PDGFRAex11.chr4.55141008.55141140_tile_1	1	Human	hg19	chr4	55140883	55141049	+	TTGGACTCTACTGTGTCCAGTCACTGTGCTGCTTCAGTGAAGCTCTGGTGCACTGGGACTTTGGTAATTCACCAGTTACCTGTCCTGGTCATTTATAGAAACCGAGGTATGAA
PDGFRAex11.chr4.55141008.55141140_tile_2	PDGFRAex11.chr4.55141008.55141140_tile_2	1	Human	hg19	chr4	55140995	55141177	-	GAACTTACCAAGCACTAGTCCATCTCTTGGAAACTCCCATCTTGAGTCATAAGGCAGCTGCATCGGGTCCACATAAATATATTCATGTCCATCTGGGCTGATTGATTCAATGACCCTCCAGCGAATT
PDGFRAex13.chr4.55144063.55144173_tile_1	PDGFRAex13.chr4.55144063.55144173_tile_1	1	Human	hg19	chr4	55144028	55144218	+	TTCAACAGCCACGGCCAGATCCAGTGAAAAACAAGCTCTCATGTCTGAACTGAAGATAATGACTCACCTGGGGCCACATTTGAACATTGTAAACTTGCTGGGAGCCTGCACCAAGTCAGGTGGGCTCACTGACCTGG
PDGFRAex17.chr4.55152008.55152130_tile_1	PDGFRAex17.chr4.55152008.55152130_tile_1	1	Human	hg19	chr4	55151889	55152061	+	CCAAGTGCCACCATGGATCAGCCAGTCTTGCAGGGGTGATGCTATTCAGCTACAGATGGCTTGATCCTGAGTCATTTCTTCCTTTTCCATGCAGTGTGTCCACCGTGATCTGGCTGCTC
PDGFRAex17.chr4.55152008.55152130_tile_2	PDGFRAex17.chr4.55152008.55152130_tile_2	1	Human	hg19	chr4	55152009	55152195	-	GGATGAGCCTGACCAGTGAGGGAAGTGAGGACGTACACTGCCTTTCGACACATAGTTCGAATCATGCATGATGTCTCTGGCCAGGCCAAAGTCACAGATCTTCACAATTTTTCCTTGTGCCAGGAGGACGTTGCG
PIK3CAex1.chr3.178916648.178916965_tile_1	PIK3CAex1.chr3.178916648.178916965_tile_1	1	Human	hg19	chr3	178916522	178916693	+	GACAACCATACATCTAATTCCTTAAAGTAGTTTTATATGTAAAACTTGCAAAGAATCAGAACAATGCCTCCACGACCATCATCAGGTGAACTGTGGGGCATCCACTTGATGCC
PIK3CAex1.chr3.178916648.178916965_tile_2	PIK3CAex1.chr3.178916648.178916965_tile_2	1	Human	hg19	chr3	178916615	178916784	-	ATGCTTTATGGTTATTAATGTAGCCTCACGGAGGCATTCTAAAGTCACTATCATTCCATTTGGTAGTAAACATTCTACTAGGATTCTTGGGGGCATCAAGTGGATGCCCCACAG
PIK3CAex1.chr3.178916648.178916965_tile_3	PIK3CAex1.chr3.178916648.178916965_tile_3	1	Human	hg19	chr3	178916723	178916887	+	ATGAACTATTTAAAGAAGCAAGAAAATACCCCCTCCATCAACTTCTTCAAGATGAATCTTCTTACATTTTCGTAAGTGTTACTCAAGAAGCAGAAAGGGAAGAATT
PIK3CAex1.chr3.178916648.178916965_tile_4	PIK3CAex1.chr3.178916648.178916965_tile_4	1	Human	hg19	chr3	178916831	178917022	-	ATTTTAGAATAGGATATTGTATCATACCAATTTCTCGATTGAGGATCTTTTCTTCACGGTTGCCTACTGGTTCAATTACTTTTAAAAAGGGTTGAAAAAGCCGAAGGTCACAAAGTCGTCTTGTTTCATCAAAAA
PIK3CAex2.chr3.178917478.178917687_tile_1	PIK3CAex2.chr3.178917478.178917687_tile_1	1	Human	hg19	chr3	178917369	178917534	+	AGTTCCCTGTTTGCAAAAAAAACATGTTCATGCTGTGTATGTAATAGAATGTTATATTCTTTATGTAATTTTATTAAAGGTTTTGCTATCGGCATGCCAGTGTGTG
PIK3CAex2.chr3.178917478.178917687_tile_2	PIK3CAex2.chr3.178917478.178917687_tile_2	1	Human	hg19	chr3	178917473	178917646	-	ATTGCTCTACTATGAGGTGAATTGAGGTCCCTAAGATCCACAGCTTCTTTACAAACGTTCAGAATATTTCTTCGGAAGTCCTGTACTTCTGGATCTTTAACCATATCAAATTCACACA
PIK3CAex2.chr3.178917478.178917687_tile_3	PIK3CAex2.chr3.178917478.178917687_tile_3	1	Human	hg19	chr3	178917589	178917762	+	TGTATGTCTATCCTCCAAATGTAGAATCTTCACCAGAATTGCCAAAGCACATATATAATAAATTAGATAAAGGTAAGAAAATGACTAATCTACTCTAATCATTACTATAGTGCAGTC
PIK3CAex7.chr3.178927974.178928126_tile_1	PIK3CAex7.chr3.178927974.178928126_tile_1	1	Human	hg19	chr3	178927877	178928046	+	GGAAGAAAAGTGTTTTGAAATGTGTTTTATAATTTAGACTAGTGAATATTTTTCTTTGTTTTTTAAGGAACACTGTCCATTGGCATGGGGAAATATAAACTTGTTTGATT
PIK3CAex7.chr3.178927974.178928126_tile_2	PIK3CAex7.chr3.178927974.178928126_tile_2	1	Human	hg19	chr3	178927989	178928183	-	ATATCTAATTTATGACAATAAAAACCTTACTTTATTTGGATTTGATCCAGTAACACCAATAGGGTTCAGCAAATCTTCTAATCCATGAGGTACTGGCCAAAGATTCAAAGCCATTTTTCCAGATACTAGAGTGTCTGTGTA
PIK3CAex9.chr3.178935998.178936122_tile_2	PIK3CAex9.chr3.178935998.178936122_tile_2	1	Human	hg19	chr3	178936011	178936201	-	TATTTTTTCTGTAATAAAGAAAAAGAAACAGAGAATCTCCATTTTAGCACTTACCTGTGACTCCATAGAAAATCTTTCTCCTGCTCAGTGATTTCAGAGAGAGGATCTCGTGTAGAAATTGCTTTGAGCTGTTCTTT
PIK3CAex9_OT.chr22.17052960.17053096_tile_2	PIK3CAex9_OT.chr22.17052960.17053096_tile_2	1	Human	hg19	chr22	17052931	17053120	-	TATTTTTTCTGTAATAAAGAAAAAGAAACAGAGAATCTCCATTTTAGCACTTACCTGTGGTCCATAGAAAATCTTTCTCCTGCGCAGTGATTTCAGAGAGAGGATCTCGTGTAGAAATTGCTTTGAGCTGTTCTTT
PIK3CAex20.chr3.178951882.178952152_tile_1	PIK3CAex20.chr3.178951882.178952152_tile_1	1	Human	hg19	chr3	178951769	178951934	+	TAATTTTGTGACATTTGAGCAAAGACCTGAAGGTATTAACATCATTTGCTCCAAACTGACCAAACTGTTCTTATTACTTATAGGTTTCAGGAGATGTGTTACAAGGCT
PIK3CAex20.chr3.178951882.178952152_tile_2	PIK3CAex20.chr3.178951882.178952152_tile_2	1	Human	hg19	chr3	178951853	178952017	-	ATTGTAGTTCTGGCATTCCAGAGCCAAGCATCATTGAGAAAAGATTTATGAAGAGATTGGCATGCTGTCGAATAGCTAGATAAGCCTTGTAACACATCTCCTGAAA
PIK3CAex20.chr3.178951882.178952152_tile_3	PIK3CAex20.chr3.178951882.178952152_tile_3	1	Human	hg19	chr3	178951939	178952112	+	TGGAATGCCAGAACTACAATCTTTTGATGACATTGCATACATTCGAAAGACCCTAGCCTTAGATAAAACTGAGCAAGAGGCTTTGGAGTATTTCATGAAACAAATGAATGATGCACAT
PIK3CAex20.chr3.178951882.178952152_tile_4	PIK3CAex20.chr3.178951882.178952152_tile_4	1	Human	hg19	chr3	178952057	178952243	-	GCTGAGAGTTATTAACAGTGCAGTGTGGAATCCAGAGTGAGCTTTCATTTTCTCAGTTATCTTTTCAGTTCAATGCATGCTGTTTAATTGTGTGGAAGATCCAATCCATTTTTGTTGTCCAGCCACCATGA
PTENex1.chr10.89624227.89624305_tile_1	PTENex1.chr10.89624227.89624305_tile_1	1	Human	hg19	chr10	89624194	89624360	+	CTCCCAGACATGACAGCCATCATCAAAGAGATCGTTAGCAGAAACAAAAGGAGATATCAAGAGGATGGATTCGACTTAGACTTGACCTGTATCCATTTCTGCGGCTGCTCCTCTTT
PTENex1_OT.chr9.33676536.33676658 _tile_1	PTENex1_OT.chr9.33676536.33676658 _tile_1	1	Human	hg19	chr9	33676510	33676682	-	CTCCCAGACAGGACAGCCATCATCAAAGAGATCGTTAGCAGAAACAAAAGGAGATATCAAGAGGATGGATTCGACTTAGACTTGACCTATATTTATCTAAACATTATTGCTATGGGATTTCCT
PTENex2.chr10.89653782.89653866_tile_1	PTENex2.chr10.89653782.89653866_tile_1	1	Human	hg19	chr10	89653653	89653842	+	GAAAACTTTCTTTTCATAACTAGCTAATGTTTTAAAAAGTATTCTTTTAGTTTGATTGCTGCATATTTCAGATATTTCTTTCCTTAACTAAAGTACTCAGATATTTATCCAAACATTATTGCTATGGGATTTCCT
PTENex2.chr10.89653782.89653866_tile_2	PTENex2.chr10.89653782.89653866_tile_2	1	Human	hg19	chr10	89653787	89653967	-	AAATCTTTTCTAAATGAAAACACAACATGAATATAAACATCAATATTTGAAATAGAAAATCAAAGCATTCTTACCTTACTACATCATCAATATTGTTCCTGTATACGCCTTCAAGTCTTTCTGCA
PTENex3.chr10.89685270.89685314_tile_1	PTENex3.chr10.89685270.89685314_tile_1	1	Human	hg19	chr10	89685239	89685405	+	TAAGGTTTTTGGATTCAAAGCATAAAAACCATTACAAGATATACAATCTGTAAGTATGTTTTCTTATTTGTATGCTTGCAAATATCTTCTAAAACAACTATTAAGTGAAAGTT
PTENex4.chr10.89690803.89690846_tile_1	PTENex4.chr10.89690803.89690846_tile_1	1	Human	hg19	chr10	89690754	89690946	+	TTTTAAACTTTTCTTTTAGTTGTGCTGAAAGACATTATGACACCGCCAAATTTAATTGCAGAGGTAGGTATGAATGTACTGTACTATGTTGTATAACTTAAACCCGATAGACTGTATCTTACTGTCATAACAATAA
PTENex5.chr10.89692770.89693008_tile_1	PTENex5.chr10.89692770.89693008_tile_1	1	Human	hg19	chr10	89692643	89692808	+	TGTTAAGTTTGTATGCAACATTTCTAAAGTTACCTACTTGTTAATTAAAAATTCAAGAGTTTTTTTTTCTTATTCTGAGGTTATCTTTTTACCACAGTTGCACAATATCC
PTENex5.chr10.89692770.89693008_tile_2	PTENex5.chr10.89692770.89693008_tile_2	1	Human	hg19	chr10	89692741	89692906	-	TTGCTGCAACATGATTGTCATCTTCACTTAGCCATTGGTCAAGATCTTCACAAAAGGGTTTGATAAGTTCTAGCTGTGGTGGGTTATGGTCTTCAAAAGGATATTGTGCAA
PTENex5.chr10.89692770.89693008_tile_3	PTENex5.chr10.89692770.89693008_tile_3	1	Human	hg19	chr10	89692855	89693047	+	ATTCACTGTAAAGCTGGAAAGGGACGAACTGGTGTAATGATATGTGCATATTTATTACATCGGGGCAAATTTTTAAAGGCACAAGAGGCCCTAGATTTCTATGGGGAAGTAAGGACCAGAGACAAAAAGGTAAGTTATTTT
PTENex5_OT.chr9.33676091.33676311_tile_3	PTENex5_OT.chr9.33676091.33676311_tile_3	1	Human	hg19	chr9	33676091	33676311	-	ATTCACTGTAAAGCTGGAAAGGGACGAACTGGTATAATGATTTATGCATATTTATTACATCGGGGCAAATTTTTAAAGGCACAAGAGGCCCTAGATTTCTATGGGGAAGTAAGGACCAGAGACAAAAAGGGAGTAACTATTCCCAGTCAGAGGCGCTATGTGTATT
PTENex6.chr10.89711875.89712016_tile_1	PTENex6.chr10.89711875.89712016_tile_1	1	Human	hg19	chr10	89711762	89711941	+	CCAGTTACCATAGCAATTTAGTGAAATAACTATAATGGAACATTTTTTTTCAATTTGGCTTCTCTTTTTTTTCTGTCCACCAGGGAGTAACTATTCCCAGTCAGAGGCGCTATGTGTATT
PTENex6.chr10.89711875.89712016_tile_2	PTENex6.chr10.89711875.89712016_tile_2	1	Human	hg19	chr10	89711884	89712057	-	TTCAAGCACTTACTGCAAGTTCCGCCACTGAACATTGGAATAGTTTCAAACATCATCTTGTGAAACAACAGTGCCACTGGTCTATAATCCAGATGATTCTTTAACAGGTAGCTATAATA
PTENex6_OT.chr9.33675905.33676121_tile_2	PTENex6_OT.chr9.33675905.33676121_tile_2	1	Human	hg19	chr9	33675875	33676148	+	CAGGTAACGGCTGAGGGAACTCAAAATACATGAACTTGTCCTCCCATCGTGTGGGTCCTGAATTGGAGGAATACATCTTCACCTTTAGCTGGCAGACCACAAACTGAGGATTGCAAGTTCCGCCACTGAACATTGGAATAGTTTCAAACATCATCTTGTGAAACAACAGTGCCACTGGTCTATAATCCAGATGATTCTTTACCAGGTAGCTATAGTA
PTENex7.chr10.89717610.89717776_tile_1	PTENex7.chr10.89717610.89717776_tile_1	1	Human	hg19	chr10	89717483	89717647	+	TGTATATTGCTGATATTAATCATTAAAATCGTTTTTGACAGTTTGACAGTTAAAGGCATTTCCTGTGAAATAATACTGGTATGTATTTAACCATGCAGATCCTCAGTTT
PTENex7.chr10.89717610.89717776_tile_2	PTENex7.chr10.89717610.89717776_tile_2	1	Human	hg19	chr10	89717583	89717750	-	CAGGTAACGGCTGAGGGAACTCAAAGTACATGAACTTGTCTTCCCGTCGTGTGGGTCCTGAATTGGAGGAATATATCTTCACCTTTAGCTGGCAGACCACAAACTGAG
PTENex7.chr10.89717610.89717776_tile_3	PTENex7.chr10.89717610.89717776_tile_3	1	Human	hg19	chr10	89717697	89717891	+	GTGTGTGGTGATATCAAAGTAGAGTTCTTCCACAAACAGAACAAGATGCTAAAAAAGGTTTGTACTTTACTTTCATTGGGAGAAATATCCAAAATAAGGACAGATTAAAAGCTATATTTTATTTTATGACATGTAAGGAACTA
PTENex9.chr10.89725044.89725229_tile_2	PTENex9.chr10.89725044.89725229_tile_2	1	Human	hg19	chr10	89725011	89725178	-	ATCTATAATGATCAGGTTCATTGTCACTAACATCTGGTGTTACAGAAGTTGAACTGCTAGCCTCTGGATTTGACGGCTCCTCTACTGTTTTTGTGAAGTACAGCTTCACCTA
SMAD4ex8.chr18.48591793.48591976_tile_1	SMAD4ex8.chr18.48591793.48591976_tile_1	1	Human	hg19	chr18	48591668	48591834	+	CCTTTACCCTTTCTTTTAGGAAAAACTGTGTTGTGGAGTGCAAGTGAAAGCCTTATATCTTTCTCATGGGAGGATGTTCTTTCCCATTTATTTCCTATAGCTCCTGAGTATTG
SMAD4ex8.chr18.48591793.48591976_tile_2	SMAD4ex8.chr18.48591793.48591976_tile_2	1	Human	hg19	chr18	48591764	48591928	-	TCCACGTATCCATCAACAGTAACAATAGGGCAGCTTGAAGGAACCTTAAATGTCTCTCCTACCTGAACATCCATTTCAAAGTAAGCAATGGAACACCAATACTCAGGA
SMAD4ex8.chr18.48591793.48591976_tile_3	SMAD4ex8.chr18.48591793.48591976_tile_3	1	Human	hg19	chr18	48591872	48592061	+	ACCCTTCTGGAGGAGATCGCTTTTGTTTGGGTCAACTCTCCAATGTCCACAGGACAGAAGCCATTGAGAGAGCAAGGTATTGATTGTATAGTCAGATAGTTACTTTAAAAAATTGAGCATAGTACATTGTCTT
SMAD4ex11.chr18.48604626.48604837_tile_2	SMAD4ex11.chr18.48604626.48604837_tile_2	1	Human	hg19	chr18	48604585	48604750	-	CTGTCTTGGGTAATCCGGTCCCCAGCCTTTCACAAAACTCATCCTGAGTATGCATAAGCGACGAAGGTCATCAACACCAATTCCAGCAGCAGCTGACAGACCTAACAGAAAAG
SMAD4ex11.chr18.48604626.48604837_tile_3	SMAD4ex11.chr18.48604626.48604837_tile_3	1	Human	hg19	chr18	48604699	48604885	+	GAGCATCAAAGAAACACCTTGCTGGATTGAAATTCACTTACACCGGGCCCTCCAGCTCCTAGACGAAGTACTTCATACCATGCCGATTGCAGACCCACAACCTTTAGACTGAGGTCTTTTACCGTTGGGGCCC
SRCex10.chr20.36031654.36031785_tile_1	SRCex10.chr20.36031654.36031785_tile_1	1	Human	hg19	chr20	36031559	36031751	+	CCGCGAGGTGCTGGACCAGGTGGAGCGGGGCTACCGGATGCCCTGCCCGCCGGAGTGTCCCGAGTCCCTGCACGACCTCATGTGCCAGTGCTGGCGGAAGGAGCCTGAGGAGCGGCCCACCTTCGAGTACCTGCAGGCCTTCCTG
SRCex10.chr20.36031654.36031785_tile_2	SRCex10.chr20.36031654.36031785_tile_2	1	Human	hg19	chr20	36031705	36031898	-	CAGGCAGGCAGAGTGGGGCAAGCCCCGAGACAGGGGCCACCCAGCCCAGGATCCAAGCCGAGAAGCCGGTCTGGGCCCGCCTGTGCCTAGAGGTTCTCCCCGGGCTGGTACTGGGGCTCGGTGGACGTGAAGTAGTCCTCC
STK11ex1.chr19.1206913.1207202_tile_1	STK11ex1.chr19.1206913.1207202_tile_1	1	Human	hg19	chr19	1206810	1206977	+	TCGGAACACAAGGAAGGACCGCTCACCCGCGGACTCAGGGCTGGCGGCGGGACTCCAGGACCCTGGGTCCAGCATGGAGGTGGTGGACCCGCAGCAGCTGGGCATGTT
STK11ex1.chr19.1206913.1207202_tile_2	STK11ex1.chr19.1206913.1207202_tile_2	1	Human	hg19	chr19	1206896	1207064	-	CGCTTGCGGCGCGGCTGGTAGATGACCTCGGTGGAGTCGATGCGGTGGATGAACGTGTCCATACCCACCGACATCAGCTCGCCCTCCGTGAACATGCCCAGCTGCTGCGGGTCCACCACC
STK11ex1.chr19.1206913.1207202_tile_3	STK11ex1.chr19.1206913.1207202_tile_3	1	Human	hg19	chr19	1207010	1207176	+	GCGGGCCAAGCTCATCGGCAAGTACCTGATGGGGGACCTGCTGGGGGAAGGCTCTTACGGCAAGGTGAAGGAGGTGCTGGACTCGGAGACGCTGTGCAGGAGGGCCGTCAAGATC
STK11ex4.chr19.1220372.1220504_tile_1	STK11ex4.chr19.1220372.1220504_tile_1	1	Human	hg19	chr19	1220249	1220423	+	GGGCCTGTGGTGTTTGGGAGGCTCCCAGGCAGCTGCAAAGGGGACCCCTGTGAGGGGCAGGGAGGCCTCGGCCCCAGGACGGGTGTGTGCTGCCCGCAGGTACTTCTGTCAGCTGATTGACGGCCTGG
STK11ex6.chr19.1221212.1221339_tile_2	STK11ex6.chr19.1221212.1221339_tile_2	1	Human	hg19	chr19	1221195	1221368	-	CTCCCACCTTTCAGCAGGTCAGAGAGCGGGGGGCCACAGTCGCCCGGGATGGCGTAGCTCCCCTTCCCGATGTTCTCAAACAACTTGTAGATGTTGTCCCCTTCGAAGGGGTACAGACCCGTGGTG
STK11ex8.chr19.1222984.1223171_tile_1	STK11ex8.chr19.1222984.1223171_tile_1	1	Human	hg19	chr19	1222915	1223091	+	GCCCTGGTGCCAGCCTGACAGGCGCCACTGCTTCTGGGCGTTTGCAGCTGGTTCCGGAAGAAACATCCTCCGGCTGAAGCACCAGTGCCCATCCCACCGAGCCCAGACACCAAGGACCGGTGGCGCAGCATG
STK11ex8.chr19.1222984.1223171_tile_2	STK11ex8.chr19.1222984.1223171_tile_2	1	Human	hg19	chr19	1223041	1223222	-	AGCCGGGCAGGGGCCCCCGCCAGACTCACCGGGCACCGTGAAGTCCTGAGTGTAGATGATGTCATCCTCGATGTCGAAGAGGTCCTCGTCCTCGTCCGCGCCGTGCAGGTCCTCCAAGTACGGCACCACAGTC
TP53ex2ex3ex4.chr17.7579241.7580010_tile_3	TP53ex2ex3ex4.chr17.7579241.7580010_tile_3	1	Human	hg19	chr17	7579229	7579399	+	GGGATACGGCCAGGCATTGAAGTCTCATGGAAGCCAGCCCCTCAGGGCAACTGACCGTGCAAGTCACAGACTTGGCTGTCCCAGAATGCAAGAAGCCCAGACGGAAACCGTAGCTG
TP53ex2ex3ex4.chr17.7579241.7580010_tile_4	TP53ex2ex3ex4.chr17.7579241.7580010_tile_4	1	Human	hg19	chr17	7579327	7579496	-	CCCCGTGGCCCCTGCACCAGCAGCTCCTACACCGGCGGCCCCTGCACCAGCCCCCTCCTGGCCCCTGTCATCTTCTGTCCCTTCCCAGAAAACCTACCAGGGCAGCTACGGTTTCCGTCTGGGC
TP53ex2ex3ex4.chr17.7579241.7580010_tile_5	TP53ex2ex3ex4.chr17.7579241.7580010_tile_5	1	Human	hg19	chr17	7579443	7579612	+	GGCCACGGGGGGAGCAGCCTCTGGCATTCTGGGAGCTTCATCTGGACCTGGGTCTTCAGTGAACCATTGTTCAATATCGTCCGGGGACAGCATCAAATCATCCATTGCTTGGGACGGCAAGG
TP53ex2ex3ex4.chr17.7579241.7580010_tile_7	TP53ex2ex3ex4.chr17.7579241.7580010_tile_7	1	Human	hg19	chr17	7579669	7579839	+	CCAGAACGTTGTTTTCAGGAAGTCTGAAAGACAAGAGCAGAAAGTCAGTCCCATGGAATTTTCGCTTCCCACAGGTCTCTGCTAGGGGGCTGGGGTTGGGGTGGGGGTGGTGGG
TP53ex2ex3ex4.chr17.7579241.7580010_tile_8	TP53ex2ex3ex4.chr17.7579241.7580010_tile_8	1	Human	hg19	chr17	7579765	7579935	-	GGAGGAGCCGCAGTCAGATCCTAGCGTCGAGCCCCCTCTGAGTCAGGAAACATTTTCAGACCTATGGAAACTGTGAGTGGATCCATTGGAAGGGCAGGCCCACCACCCCCACCCCAACCCCAGC
TP53ex2ex3ex4.chr17.7579241.7580010_tile_9	TP53ex2ex3ex4.chr17.7579241.7580010_tile_9	1	Human	hg19	chr17	7579879	7580062	+	CGGCTCCTCCATGGCAGTGACCCGGAAGGCAGTCTGGCTGCTGCAAGAGGAAAAGTGGGGATCCAGCATGAGACACTTCCAACCCTGGGTCACCTGGGCCTGCAGAGAAGGAACCCCCTCCCCCAACACCATGCCA
TP53ex5TP53ex6.chr17.7578157.7578574_tile_2	TP53ex5TP53ex6.chr17.7578157.7578574_tile_2	1	Human	hg19	chr17	7578118	7578295	-	CTTATCCGAGTGGAAGGAAATTTGCGTGTGGAGTATTTGGATGACAGAAACACTTTTCGACATAGTGTGGTGGTGCCCTATGAGCCGCCTGAGGTCTGGTTTGCAACTGGGGTCTCTGGGAGGAGGGG
TP53ex5TP53ex6.chr17.7578157.7578574_tile_3	TP53ex5TP53ex6.chr17.7578157.7578574_tile_3	1	Human	hg19	chr17	7578242	7578434	+	AGATGCTGAGGAGGGGCCAGACCTAAGAGCAATCAGTGAGGAATCAGAGGCCTGGGGACCCTGGGCAACCAGCCCTGTCGTCTCTCCAGCCCCAGCTGCTCACCATCGCTATCTGAGCAGCGCTCATGGTGGGGGCAGCG
TP53ex5TP53ex6.chr17.7578157.7578574_tile_4	TP53ex5TP53ex6.chr17.7578157.7578574_tile_4	1	Human	hg19	chr17	7578354	7578523	-	CTGTGGGTTGATTCCACACCCCCGCCCGGCACCCGCGTCCGCGCCATGGCCATCTACAAGCAGTCACAGCACATGACGGAGGTTGTGAGGCGCTGCCCCCACCATGAGCGCTGCTCAG
TP53ex5TP53ex6.chr17.7578157.7578574_tile_5	TP53ex5TP53ex6.chr17.7578157.7578574_tile_5	1	Human	hg19	chr17	7578474	7578651	+	GCTGCACAGGGCAGGTCTTGGCCAGTTGGCAAAACATCTTGTTGAGGGCAGGGGAGTACTGTAGGAAGAGGAAGGAGACAGAGTTGAAAGTCAGGGCACAAGTGAACAGATAAAGCAACTGGAAGACGG
TP53ex7.chr17.7577498.7577608_tile_1	TP53ex7.chr17.7577498.7577608_tile_1	1	Human	hg19	chr17	7577473	7577649	+	CCTGGAGTCTTCCAGTGTGATGATGGTGAGGATGGGCCTCCGGTTCATGCCGCCCATGCAGGAACTGTTACACATGTAGTTGTAGTGGATGGTGGTACAGTCAGAGCCAACCTAGGAGATAACACAG
TP53ex8TP53ex9.chr17.7576833.7577175_tile_2	TP53ex8TP53ex9.chr17.7576833.7577175_tile_2	1	Human	hg19	chr17	7576806	7576970	-	CCTTGCCTCTTTCCTAGCACTGCCCAACAACACCAGCTCCTCTCCCCAGCCAAAGAAGAAACCACTGGATGGAGAATATTTCACCCTTCAGGTACTAAGTCTTGGGAC
TP53ex8TP53ex9.chr17.7576833.7577175_tile_3	TP53ex8TP53ex9.chr17.7576833.7577175_tile_3	1	Human	hg19	chr17	7576918	7577100	+	GGAAAGGTGATAAAAGTGAATCTGAGGCATAACTGCACCCTTGGTCTCCTCCACCGCTTCTTGTCCTGCTTGCTTACCTCGCTTAGTGCTCCCTGGGGGCAGCTCGTGGTGAGGCTCCCCTTTCTTGCGGAGATTC
TP53ex8TP53ex9.chr17.7576833.7577175_tile_4	TP53ex8TP53ex9.chr17.7576833.7577175_tile_4	1	Human	hg19	chr17	7577050	7577219	-	TCCTTACTGCCTCTTGCTTCTCTTTTCCTATCCTGAGTAGTGGTAATCTACTGGGACGGAACAGCTTTGAGGTGCGTGTTTGTGCCTGTCCTGGGAGAGACCGGCGCACAGAGGAAGAG
TP53ex10.chr17.7573926.7574033_tile_1	TP53ex10.chr17.7573926.7574033_tile_1	1	Human	hg19	chr17	7573869	7574062	+	GGGAGTAGGGCCAGGAAGGGGCTGAGGTCACTCACCTGGAGTGAGCCCTGCTCCCCCCTGGCTCCTTCCCAGCCTGGGCATCCTTGAGTTCCAAGGCCTCATTCAGCTCTCGGAACATCTCGAAGCGCTCACGCCCACGGATCTG
TP53ex11.chr17.7572907.7573028_tile_1	TP53ex11.chr17.7572907.7573028_tile_1	1	Human	hg19	chr17	7572883	7573055	+	GGGGAACAAGAAGTGGAGAATGTCAGTCTGAGTCAGGCCCTTCTGTCTTGAACATGAGTTTTTTATGGCGGGAGGTAGACTGACCCTTTTTGGACTTCAGGTGGCTGTAGGAGACAGAAGCAGG
[Intervals]									
Species	Build ID	Chromosome	Target Start	Target Stop					
Human	hg19	chr1	115251147	115251280					
Human	hg19	chr1	115252185	115252354					
Human	hg19	chr1	115256416	115256604					
Human	hg19	chr1	115258677	115258786					
Human	hg19	chr2	29443642	29443706					
Human	hg19	chr2	48030554	48030829					
Human	hg19	chr3	41266012	41266161					
Human	hg19	chr3	138665109	138665221					
Human	hg19	chr3	178916609	178916970					
Human	hg19	chr3	178917473	178917692					
Human	hg19	chr3	178927969	178928131					
Human	hg19	chr3	178936039	178936127					
Human	hg19	chr3	178951877	178952157					
Human	hg19	chr4	55141003	55141145					
Human	hg19	chr4	55144058	55144178					
Human	hg19	chr4	55152003	55152135					
Human	hg19	chr4	55592018	55592221					
Human	hg19	chr4	55593577	55593713					
Human	hg19	chr4	55594175	55594292					
Human	hg19	chr4	55599231	55599363					
Human	hg19	chr4	55602662	55602780					
Human	hg19	chr4	153244028	153244303					
Human	hg19	chr4	153245331	153245551					
Human	hg19	chr4	153247153	153247388					
Human	hg19	chr4	153249355	153249546					
Human	hg19	chr4	153250819	153250942					
Human	hg19	chr5	112173743	112173988					
Human	hg19	chr5	112174526	112174778					
Human	hg19	chr5	112174975	112175370					
Human	hg19	chr5	112175469	112176130					
Human	hg19	chr7	55241609	55241741					
Human	hg19	chr7	55242412	55242518					
Human	hg19	chr7	55248981	55249176					
Human	hg19	chr7	55259407	55259572					
Human	hg19	chr7	116339543	116340298					
Human	hg19	chr7	116380901	116381084					
Human	hg19	chr7	116411898	116412048					
Human	hg19	chr7	116417441	116417528					
Human	hg19	chr7	116418825	116419016					
Human	hg19	chr7	116422037	116422156					
Human	hg19	chr7	116423353	116423526					
Human	hg19	chr7	116435936	116436183					
Human	hg19	chr7	140453072	140453195					
Human	hg19	chr7	140481371	140481498					
Human	hg19	chr9	80343425	80343586					
Human	hg19	chr9	80409374	80409513					
Human	hg19	chr9	80412431	80412569					
Human	hg19	chr10	89624222	89624310					
Human	hg19	chr10	89653777	89653871					
Human	hg19	chr10	89685266	89685319					
Human	hg19	chr10	89690798	89690851					
Human	hg19	chr10	89692765	89693013					
Human	hg19	chr10	89711870	89712021					
Human	hg19	chr10	89717605	89717781					
Human	hg19	chr10	89725041	89725152					
Human	hg19	chr10	123279488	123279688					
Human	hg19	chr12	25362724	25362850					
Human	hg19	chr12	25378543	25378712					
Human	hg19	chr12	25380163	25380351					
Human	hg19	chr12	25398203	25398323					
Human	hg19	chr14	105246425	105246558					
Human	hg19	chr15	66727437	66727561					
Human	hg19	chr16	68846033	68846171					
Human	hg19	chr16	68847213	68847403					
Human	hg19	chr16	68855899	68856128					
Human	hg19	chr17	7572922	7573013					
Human	hg19	chr17	7573922	7574036					
Human	hg19	chr17	7576848	7576931					
Human	hg19	chr17	7577014	7577160					
Human	hg19	chr17	7577498	7577613					
Human	hg19	chr17	7578172	7578294					
Human	hg19	chr17	7578366	7578559					
Human	hg19	chr17	7579307	7579586					
Human	hg19	chr17	7579699	7579726					
Human	hg19	chr17	7579834	7579917					
Human	hg19	chr17	37880974	37881169					
Human	hg19	chr18	48591788	48591981					
Human	hg19	chr18	48604621	48604842					
Human	hg19	chr19	1206908	1207149					
Human	hg19	chr19	1220367	1220400					
Human	hg19	chr19	1221221	1221344					
Human	hg19	chr19	1222979	1223176					
Human	hg19	chr20	36031584	36031787					
Human	hg19	chr20	57480433	57480540					
Human	hg19	chr20	57484403	57484483					
