Reformat and Upload a Gene List
|
1.
|
Open the original TruSeq Custom Amplicon design gene list file (*.csv) in a spreadsheet editor, such as Excel. |
|
2.
|
Delete the following columns: |
|
3.
|
Rename the TargetType column into Type and move it to the left of the Gene column. |
|
4.
|
Enter Chromosome in the header of the column to the right of the Gene column. |
|
5.
|
Enter Start in the header of the column to the right of the Chromosome column. |
|
6.
|
Enter End in the header of the column to the right of the Start column. |
|
7.
|
Rename the Gene column into Name. |
|
8.
|
Enter GENE_CDS for all CDS entries and GENE_EXON for all Exon entries in the Type column. |
|
9.
|
Enter GENE_CDS or GENE_EXON for each FullRegion entry in the Type column. Alternatively, use a coordinate input file to upload FullRegion entries. See Reformat and Upload a Coordinates File. |
NOTE
The full target region will not be covered when using GENE_CDS or GENE_EXON for FullRegion entries.
|
10.
|
The Chromosome, Start, and End columns can be empty. |
|
11.
|
Save and close the gene list file. |
Make sure to select the species that matches the original TruSeq Custom Amplicon design. For human TruSeq Custom Amplicon designs, select Human (hg19).
|
13.
|
Configure the new AmpliSeq for Illumina design by selecting the Sample Type and Max Amplicon Length that most closely match those of the original TruSeq Custom Amplicon design. |
Use the following table for selecting equivalent amplicon sizes between the two assay types:
|
150
|
140
|
|
175
|
175
|
|
250
|
275
|
|
425
|
375
|
|
14.
|
Use the default setting for Stringency. |