Order the NovaSeq X Series
Advanced chemistry, optics, and informatics combine to deliver exceptional speed and data quality, outstanding throughput and scalability.
Operationalize informatics and drive scientific insights with Illumina Connected Analytics. Contact us for information on pricing, subscriptions, and more.
Illumina Connected Analytics provides labs the ability to quickly extract biological and clinical insights from the vast amount of genomic data generated from NGS and microarray studies. Using a flexible and comprehensive cloud-based platform, Illumina Connected Analytics provides secure data management, scalable infrastructure, and the ability to build, validate, and deploy new informatics workflows at any scale.
Illumina Connected Analytics supports customers operating in regulated environments such as those governed by General Data Protection Regulation (GDPR), Health Insurance Portability and Accountability Act (HIPPA), and International Organization for Standards (ISO) 27001.
Instruments | MiSeq System, iSeq 100 System, NextSeq 550 System, NextSeq 2000 System, NextSeq 1000 System, MiSeqDx in Research Mode, MiniSeq System, NextSeq 550Dx in Research Mode |
---|---|
Software format | Cloud |
Technology | Microarray, Sequencing |
HIPAA Compliant Attested by Schellman
Illumina Connected Analytics features an information security program that leverages the Amazon Web Services infrastructure and provides multiple layers of security. Its risk management program conforms to the specifications of the Health Insurance Portability and Accountability Act (HIPAA) Security Role and the Health Information Technology for Economic and Clinical Health (HITECH) Breach Notification Rule.
ISO 27001 Certified by Schellman
Illumina has received ISO 27001 certification of its information security management system (ISMS) supporting Illumina Connected Analytics. This certification ensures that sensitive data contained or collected by these solutions are protected. The certification was performed by Schellman, an ANSI National Accreditation Board (ANAB) and United Kingdom Accreditation Service (UKAS) accredited certification body based in the US.
ISO 27701 Certified by Schellman
Illumina Connected Analytics is compliant with global and local data privacy and requirements with 27701:2019 certification and guaranteed data residency.
GDPR Ready
Illumina Connected Analytics features multiple system controls that you can use to manage authorization, authentication, and data control, including deletion as needed. Access logs are retained for seven years. These features help researchers ensure compliance with the General Data Protection Regulation (GDPR).
ISO 13485 Medical Devices Quality Management
llumina Connected Analytics (ICA) was developed in accordance with Illumina’s Software Life Cycle (SLC) process under Illumina’s Quality Management System.
Illumina operates and maintains a Quality Management System (QMS) which complies with the requirements of ISO 13485. The scope of the QMS covers the Design, Development, Manufacture, Distribution, Installation and Servicing of Genotyping, Gene Expression and PCR – products instruments and software - used for genetic analysis. Additionally, processes within Illumina’s QMS have adopted industry best practices and relevant standards, such as ISO 14971 for Risk Management and IE62304 for SLC.
Use of Illumina Connected Analytics requires purchase of an annual license and sufficient iCredits to meet data storage and analysis needs based on throughput. Optional ICA training courses are also available.
For more information on iCredits, visit the iCredits Overview page.
Illumina Connected Analytics (ICA) is a secure and comprehensive cloud-based platform for storage, management, and analysis of large volumes of multiomics data for a broad range of applications, including drug development, cancer research, genetic disease research, and more.
A highly customizable laboratory information management system that allows genomics labs to track samples and manage workflows efficiently and securely.
Data management and simplified bioinformatics for labs getting started and for rapidly scaling next-generation sequencing (NGS) operations.
Intuitive on-instrument run setup and monitoring.
Illumina Connected Analytics
A comprehensive cloud-based genomics data platform for secure data management, infrastructure scalability, and bioinformatics workflow implementation.
Illumina DRAGEN secondary analysis provides accurate, comprehensive, and efficient analysis of NGS data.
BaseSpace Sequence Hub offers NGS data analysis apps for common Illumina sequencing methods.
Emedgene streamlines tertiary analysis workflows for rare disease genomics and other germline research applications.
An interactive omics knowledge base that analyzes private omics data with highly curated public data to help researchers put their data into biological context.
Informatics infrastructure and pipeline setup
We offer a variety of resources and information to help simplify the process of setting up your informatics infrastructure and data analysis pipeline.
Learn about the advantages of high-throughput sequencing. Explore technology innovations, high-throughput sequencers, and data analysis options.
Drug discovery and development
Explore innovative genomic analysis solutions designed to inform drug discovery efforts and support development of targeted therapeutics.
Illumina Connected Analytics requires purchase of an annual license and sufficient iCredits to meet data storage and analysis needs based on throughput.
For more information on iCredits, visit the iCredits Overview page.
Illumina Connected Analytics is a secure genomics data platform where data can be analyzed using DRAGEN pipelines or custom pipelines, scaled up or down with a broad range of analysis options, and shared privately or publicly.
Build, import, and execute custom pipelines, automate pipelines to run with specific inputs, and access and interact with data directly using the command-line interface (CLI).
Intuitive visual pipeline editor with access to DRAGEN secondary analysis, available as pre-packaged pipelines or tools to incorporate into custom pipelines.
Illumina Connected Analytics allows data to be organized in a secure workplace and shared globally in a compliant manner.
An interactive programming module, leveraging popular JupyterLab Notebooks (Python and R), Illumina Connected Analytics empowers data scientists to analyze aggregated data in a seamless and secure environment.
Store your genomic data in a secure environment
With cloud-based genomic data solutions from Illumina, you can streamline your data analysis, increase productivity, and collaborate globally in a secure and cost-effective manner.
Leveraging a cloud ecosystem for advanced genomic data analysis
Learn how Illumina Connected Analytics offers custom pipeline development, including DRAGEN tools, secure, scalable data warehousing, and an insights generation and data science module.
Illumina supports Canada's nationwide COVID-19 genome sequencing initiative
Illumina Connected Analytics is helping researchers safely and securely move petabyte-sized data sets generated by CGEn, Canada's sequencing and informatics platform, from state-of-art sequencing systems in Toronto into a common "cloud" accessible to approved researchers at leading research facilities and hospitals.
For kidney transplant recipients, a more accurate and tailored care plan
Verici Dx leverages AI workflows in Illumina Connected Analytics for clinical research on transplant prognosis.
Using analytics to improve cancer research
The University of Melbourne Centre for Cancer Research uses Illumina Connected Analytics to help develop and automate workflows that analyze, process, and disseminate genomic data among researchers and clinicians.
Introducing Illumina Connected Analytics
Analyze, manage, aggregate, and explore data at scale with Illumina Connected Analytics, a secure genomics data platform to operationalize informatics and drive scientific insights.
ICA Enterprise Annual Subscription
20038994
Illumina Connected Analytics (ICA) Enterprise Annual Subscription. This product includes 1 year of access to ICA Enterprise, including sequencing instrument connectivity, data management capabilities, custom and pre-packaged analysis tools, and the Base module for data warehousing and mining. ICA Enterprise also includes optional HIPAA BAA (US-only), single sign-on (SSO), and a service leval agreement (SLA).
ICA Professional Annual Subscription
20044876
Illumina Connected Analytics (ICA) Professional Annual Subscription. This product includes 1 year of access to ICA, including sequencing instrument connectivity, data management capabilities, access to pre- packaged tools, and the ability to create customized workflows composed of tools, pipelines, data warehouses, and notebooks.
Illumina Analytics - 1 iCredit
20042038
iCredits are used for data storage and analysis on either BaseSpace Sequence Hub or Illumina Connected Analytics.
List Price:
Discounts:
Illumina Analytics Starter Pack - 1,000 iCredits
20042039
iCredits are used for data storage and analysis on either BaseSpace Sequence Hub or Illumina Connected Analytics.
List Price:
Discounts:
Illumina Analytics - 5,000 iCredits
20042040
iCredits are used for data storage and analysis on either BaseSpace Sequence Hub or Illumina Connected Analytics.
List Price:
Discounts:
Illumina Analytics - 50,000 iCredits
20042041
iCredits are used for data storage and analysis on either BaseSpace Sequence Hub or Illumina Connected Analytics.
List Price:
Discounts:
Illumina Analytics - 100,000 iCredits
20042042
iCredits are used for data storage and analysis on either BaseSpace Sequence Hub or Illumina Connected Analytics.
List Price:
Discounts:
Illumina Analytics Consumption Billing
20012931
Illumina Analytics Consumption Billing - The not to exceed amount is represented as the amount on the quote. Customers will be invoiced monthly for consumption of compute, storage, and 3rd party Apps up to the amount associated with item number 20012931.
ICA Training and Onboarding
20049422
Illumina Connected Analytics (ICA) Training and Onboarding includes five (5) hours of product onboarding support and product training delivered virtually.
ILMN Microarray Analytics ICA Training
20081935
Training for Pharmacogenomics (PGx) Analysis using Illumina Connected Analytics (ICA) includes onboarding support and training on registering and administering a private domain on ICA, sending data to ICA when scanning on the iScan, and analyzing PGx data using ICA. The 1 hour training can be virtual or coupled with other trainings in person.
Showing of
Product
Qty
Unit Price
Product
Catalog ID
Quantity
Unit price
Yes, Illumina Connected Analytics can be configured to automate cloud secondary analysis pipelines. View secondary analysis types here.
File uploads via the UI are limited to 5 GB. File uploads via the command line interface and Connector have no size limit (uploads greater than 5 GB use multipart upload).
The following security and compliance measures are in place with Illumina Connected Analytics:
Extensive and secure global framework built on trusted cloud infrastructure
ISO 13485 – compliant in accordance with the Illumina Software Life Cycle (SLC) process under the Illumina Quality Management System (QMS)
ISO 27001– certified Information Security Management System
Complies with the principles of GDPR privacy regulations in all global instances
Support for HIPAA compliance in a regulated environment
For information on the data formats supported by Illumina Connected Analytics, see the ICA online help data formats page.
Reach out for information about our products and services, or get answers to questions about our technology.
Your email address is never shared with third parties.