| Item | Quantity | Storage | 
|---|---|---|
| MA2 | 2 tubes (per 96 samples) | -25° to -15°C | 
| MA1 | 2 tubes (per 96 samples) | -25° to -15°C | 
| TEM | 2 tubes (per 8 BeadChips) | -25° to -15°C | 
| MSM | 2 tubes (per 96 samples) | -25° to -15°C | 
| RA1 | 46 µl per sample well | -25° to -15°C | 
| RA1 | 10 ml for 1–8 BeadChips; 20 ml for 9–16 BeadChips; 30 ml for 17–24 BeadChips | -25° to -15°C | 
| STM (Make sure that all STM tubes indicate the same stain temperature on the label) | 2 tubes (per 8 BeadChips) | -25° to -15°C | 
| FMS | 2 tubes (per 96 samples) | -25° to -15°C | 
| XC1 | 2 tubes (per 8 BeadChips) | -25° to -15°C | 
| XC2 | 2 tubes (per 8 BeadChips) | -25° to -15°C | 
| ATM | 2 tubes (per 8 BeadChips) | -25° to -15°C | 
| PM1 | 2 tubes (per 96 samples) | 2° to 8°C | 
| Wash Rack | 1 (up to 8 BeadChips) | Room temperature | 
| Wash Dish | 2 (up to 8 BeadChips) | Room temperature | 
| XC4 | 310 ml for 1–8 BeadChips; 285 ml for 16– 24 BeadChips | Room temperature | 
| Te-Flow Flow-Through Chambers (with black frames, spacers, glass back plates, and clamps) | 1 (per BeadChip) | Room temperature | 
| XC3 | 50 ml for 1–8 BeadChips; 100 ml for 9–16 BeadChips; 150 ml for 17–24 BeadChips | Room temperature | 
| PB2 | 4x3 or 4x1 HD BeadChip: 3 tubes (per 48 Samples); 8x1 HD BeadChip: 2 tubes (per 96 Samples) | Room temperature | 
| Hyb Chamber gaskets | 4x3 or 4x1 HD BeadChip: 3 (per 48 Samples); 8x1 HD BeadChip: 3 (per 96 Samples) | Room temperature | 
| Hyb Chamber inserts | 4x3 or 4x1 HD BeadChip: 12 (per 48 Samples); 8x1 HD BeadChip: 12 (per 96 Samples) | Room temperature | 
| BeadChips | 4x3 or 4x1 HD BeadChip: 12 (per 48 Samples); 8x1 HD BeadChip: 12 (per 96 Samples) | Room temperature | 
| PB1 | 550 ml (up to 8 BeadChips); 310 ml for 1–8 BeadChips; 285 ml for 9–24 BeadChips | Room temperature | 
| Hyb Chambers | 4x3 or 4x1 HD BeadChip: 3 (per 48 Samples); 8x1 HD BeadChip: 3 (per 96 Samples) | Room temperature | 
| Multi-Sample BeadChip Alignment Fixture | 1 (per 8 BeadChips) | Room temperature | 
| Item | Quantity | Storage | 
|---|---|---|
| 95% formamide/1 mM EDTA | 15 ml for 1–8 BeadChips; 17 ml for 9–16 BeadChips; 25 ml for 17–24 BeadChips | -25° to -15°C | 
| WG#-DNA plate with 96 DNA samples (50 ng/µl) | 1 plate | -25° to -15°C | 
| 96-well 0.8 ml microtiter plate (MIDI) | 1 plate | |
| Lambda DNA | See instructions | 2° to 8°C | 
| PicoGreen dsDNA quantitation reagent | See instructions | 2° to 8°C | 
| 0.1N NaOH | 15 ml (per 96 samples) | 2° to 8°C | 
| 96-well 0.65 ml microtiter plate | 1 per 96 samples | Room temperature | 
| 1X TE (10 mM Tris-HCl pH8.0, 1 mM EDTA (TE)) | See instructions | Room temperature | 
| 100% 2-propanol | 40 ml (per 96 samples) | Room temperature | 
| Alconox Powder Detergent | As needed | Room temperature | 
| EtOH | As needed | Room temperature | 
| Fluotrac 200 96-well flat-bottom plate | 1 per Std DNA plate 1 per Sample DNA plate | Room temperature |