Illumina RNA Prep with Enrichment (L) Tagmentation Contents & Storage

Illumina RNA Prep with Enrichment, (L) Tagmentation (16 Samples) (20040536)

Illumina cDNA Synthesis
Quantity Reagent Description Storage
1 EPH3 Elute, Prime, Fragment, High Concentration Mix -25°C to -15°C
1 FSA First Strand Synthesis Act D Mix -25°C to -15°C
1 RSB Resuspension Buffer -25°C to -15°C
1 SSM Second Strand Mix -25°C to -15°C
1 RT Reverse Transcriptase -25°C to -15°C
1 SMM Second Strand Marking Master Mix -25°C to -15°C
Illumina DNA/RNA Prep- Tagmentation Beads
Quantity Reagent Description Storage
1 EBLTL Bead-Linked Transposomes -25°C to -15°C
2 RSB Resuspension Buffer -25°C to -15°C
Illumina DNA/RNA Prep — Tagmentation Buffers
Quantity Reagent Description Storage
1 ST2 Stop Tagment Buffer 2 -25°C to -15°C
1 TWB Tagment Wash Buffer -25°C to -15°C
Illumina DNA/RNA Prep — Tagmentation PCR Reagents
Quantity Reagent Description Storage
2 EPM Enhanced PCR Mix -25°C to -15°C
1 TB1 Tagmentation Buffer 1 -25°C to -15°C
Illumina RNA Fast Hyb Enrichment Beads + Buffers
Quantity Reagent Description Storage
1 EHB2 Enrich Hyb Buffer 2 2°C to 8°C
1 ET2 Elute Target Buffer 2 2°C to 8°C
1 RSB Resuspension Buffer 2°C to 8°C
1 SMB Streptavidin Magnetic Beads 2°C to 8°C
Illumina RNA Fast Hyb Enrichment PCR + Buffers
Quantity Reagent Description Storage
1 EE1 Enrichment Elution Buffer 1 -25°C to -15°C
1 EEW Enhanced Enrichment Wash -25°C to -15°C
1 EPM Enhanced PCR Mix -25°C to -15°C
1 HP3 2 N NaOH -25°C to -15°C
1 NHB2 Hyb Buffer 2 + IDT NXT Blockers -25°C to -15°C
1 NHB2 PCR Primer Cocktail -25°C to -15°C

Illumina RNA Prep with Enrichment, (L) Tagmentation (96 Samples) (20040537)

Illumina cDNA Synthesis
Quantity Reagent Description Storage
4 EPH3 Elute, Prime, Fragment, High Concentration Mix -25°C to -15°C
4 FSA First Strand Synthesis Act D Mix -25°C to -15°C
2 RSB Resuspension Buffer -25°C to -15°C
1 SSM Second Strand Mix -25°C to -15°C
1 RT Reverse Transcriptase -25°C to -15°C
4 SMM Second Strand Marking Master Mix -25°C to -15°C
Illumina DNA/RNA Prep- Tagmentation Beads
Quantity Reagent Description Storage
4 EBLTL Bead-Linked Transposomes -25°C to -15°C
2 RSB Resuspension Buffer -25°C to -15°C
Illumina DNA/RNA Prep — Tagmentation Buffers
Quantity Reagent Description Storage
1 ST2 Stop Tagment Buffer 2 -25°C to -15°C
2 TWB Tagment Wash Buffer -25°C to -15°C
Illumina DNA/RNA Prep — Tagmentation PCR Reagents
Quantity Reagent Description Storage
2 EPM Enhanced PCR Mix -25°C to -15°C
2 TB1 Tagmentation Buffer 1 -25°C to -15°C
Illumina RNA Fast Hyb Enrichment Beads + Buffers
Quantity Reagent Description Storage
1 EHB2 Enrich Hyb Buffer 2 2°C to 8°C
2 ET2 Elute Target Buffer 2 2°C to 8°C
2 RSB Resuspension Buffer 2°C to 8°C
2 SMB Streptavidin Magnetic Beads 2°C to 8°C
Illumina RNA Fast Hyb Enrichment PCR + Buffers
Quantity Reagent Description Storage
2 EE1 Enrichment Elution Buffer 1 -25°C to -15°C
4 EEW Enhanced Enrichment Wash -25°C to -15°C
2 EPM Enhanced PCR Mix -25°C to -15°C
1 HP3 2 N NaOH -25°C to -15°C
1 NHB2 Hyb Buffer 2 + IDT NXT Blockers -25°C to -15°C
1 NHB2 PCR Primer Cocktail -25°C to -15°C

IDT for Illumina DNA/RNA UD Indexes, Store at -25°C to -15°C

(96 Indexes, 96 Samples) (20027213, 20027214, 20042666, 20042667)

Quantity Reagent Description
1 UDP0097–UDP0192 Set A index adapter plate
1 UDP0001–UDP0096 Set B index adapter plate
1 UDP0193–UDP0288 Set C index adapter plate
1 UDP0289–UDP0384 Set D index adapter plate

Enrichment Panels (20020183, 20042472) Shipped and Store at -25°C to -15°C

Panel Name Quantity Reagent Description
Illumina Exome Panels 1 CEX Coding Exome Oligos
Respiratory Virus Panel 1 RVO Respiratory Virus Oligos